search query: @keyword mittausepävarmuus / total: 15
reference: 9 / 15
« previous | next »
Author:Mattsson, Valtteri
Title:Mittausepävarmuuden määrittäminen taajuusmuuttajan lämpenemätestissä
Denition of Measurement Uncertainty in Temperature-Rise Tests of Frequency Converters
Publication type:Master's thesis
Publication year:2008
Pages:x + 66 s. + liitt. 24      Language:   fin
Department/School:Sähkötekniikan laitos
Main subject:Tehoelektroniikka   (S-81)
Supervisor:Kyyrä, Jorma
Instructor:Yli-Juuti, Jari
Electronic version URL: http://urn.fi/urn:nbn:fi:tkk-012918
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark S80     | Archive
Keywords:measurement uncertainty
harmonics
frequency converter
temperature-rise test
mittausepävarmuus
harmoniset yliaallot
taajuusmuuttaja
lämpenemätesti
Abstract (eng): This thesis concentrates in defining measurement uncertainty in temperature measurements of frequency converters.
The influence of changes in supply network parameters is covered by analyzing the test results of the temperature-rise tests.

The measuring equipment and thermocouple wire errors can be solved by using manufacturers' data sheet information.
The surface mounting generates a error source that is more complex to analyze.
Bad thermal connection produces thermal gradient between the surface and the probe, which leads to systematic error in measurement.
The problem is larger when measuring forcedly convected surfaces.

The changes in the supplying network alter the operating point of the frequency converter which affects the temperature rise test results.
When performing single tests there won't be a problem, since the converter is designed to work in specified limits independent from supply parameters.
When sequential tests are to be performed and the supply parameters are to be kept constant a regulated supply, i.e. a generator, must be used.

According to the test results all tested supply network parameters and nonidealities in temperature measurement affect clearly to the test results.
All discussed parameters must be known if a test is to be repeated under the same conditions.
Abstract (fin):Työssä määritetään mittausepävarmuus taajuusmuuttajan lämpenemätestin lämpötilanmittauksessa.
Syöttöverkon parametrien muuttumisen vaikutusta lämpenemätestituloksiin käsitellään testatun taajuusmuuttajan tuloksia analysoimalla.

Termoparimittauksissa mittalaitteen ja termoparilangan aiheuttamat epävarmuuskomponentit saadaan ratkaistua valmistajien määrittämien ominaisuuksien perusteella.
Käytettävä termoparianturin pintakiinnitys aiheuttaa hankalammin määriteltävän virhelähteen.
Huonolla kiinnityksellä aiheutetaan lämpötilagradientti mitattavan pinnan ja anturin välille, jolloin mitattu lämpötila poikkeaa systemaattisesti mitattavan pinnan lämpötilasta.
Ongelma korostuu, kun mitattava pinta on pakotetun ilmankierron piirissä, jolloin lämpötilaero anturin ja todellisen mittauskohteen välillä kasvaa.

Sähköisten parametrien muutokset syöttöverkossa muuttavat taajuusmuuttajan toimintapistettä, jolloin myös saatavat lämpötilanmittaustulokset muuttuvat.
Yksittäiset testit voidaan suorittaa ongelmitta, koska taajuusmuuttaja on suunniteltu toimimaan myös ideaalisesta poikkeavissa verkko-olosuhteissa.
Kun vaaditaan peräkkäisiä testejä, joissa syöttöverkon ominaisuudet pysyvät vakioina, täytyy syöttöjännite tuottaa hallitusti, kuten esimerkiksi generaattorilla.

Saatujen tulosten perusteella voidaan sanoa, että kaikki testatut syöttöverkon ominaisuudet sekä lämpötilanmittauksen epäideaalisuudet vaikuttavat selkeästi saataviin tuloksiin.
Tällöin kaikki työssä esitellyt parametrit täytyy tuntea, jotta testi pystytään toistamaan samoissa olosuhteissa.