search query: @keyword building / total: 20
reference: 9 / 20
« previous | next »
Author:Valkeapää, Aki
Title:Fundamentals of air curtain design
Ilmaverhosuunnittelun perusteet
Publication type:Licentiate thesis
Publication year:2010
Pages:48 s. + liitt.      Language:   eng
Department/School:Insinööritieteiden ja arkkitehtuurin tiedekunta
Main subject:LVI-tekniikka   (Ene-58)
Supervisor:Sirén, Kai ; Sandberg, Esa
Instructor:Sirén, Kai
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  8401   | Archive
Keywords:air curtain
design
tightness
energy
draught
neutral pressure level
envelope
air balance
building
ilmaverho
ilmaverhosuunnittelu
tiiviys
energia
vetoisuus
neutraalitason korkeus
ulkovaippa
ilmatase
rakennus
oviaukko
ovi
Abstract (eng): Air curtains are used to reduce doorway-induced thermal losses and the negative effects of draught in situations where ordinary fixed doors are kept open.
This paper examines the functionality of air curtains, and related factors, with the aid of measurements made in industrial buildings.
To clarify the operating conditions of air curtains, an analysis method was developed during the project based on field research and measurements.
In addition, the paper sets out horizontal and vertical upwards blowing air curtains' tightness levels defined with tracer measurement results as the basis.
Tightness measurements were conducted to study the energy saving effects of air curtains under the climatic conditions of Finland.
The results are presented with the aid of an example calculation in the final section of this paper.

When using an air curtain under the correct operating conditions, the achievable tightness is 50 - 80 % in large doorways.
The highest tightness level was obtained in the test hall when using an upwards blowing air curtain of the recirculating type (etaac,maxac,max The highest effect of the air curtain's dimensional parameters (discharge velocity -discharge angle -nozzle width) on the air curtain's tightness was measured to be 3%.
The example calculation indicates that, compared to no controlled air curtains, a continuous blow rate will provide a saving of 5% in the typical industrial doorway size category under the climatic conditions of Finland.

According to the measurement results, temperature fluctuations may be reduced by 1 - 2°C around large doorways.
However, an air curtain generates air flows that may easily be experienced as draught when working in the proximity of doorways and door lines.
In a work site located at the door line, the lowest air flow rate values were 0.3 - 0.5 m/s.
Abstract (fin): Ilmaverho vähentää oviaukosta aiheutuvia lämpöhäviöitä ja vetohaittoja silloin, kun varsinainen kiinteä ovi on avoimena.
Tässä työssä on tutkittu ilmaverhojen toimivuutta ja toimivuuteen vaikuttavia tekijöitä teollisuusrakennuksissa mittauksin.
Työssä on kehitetty ilmaverhojen toimintaedellytysten selvittämistä varten kenttätutkimukseen ja mittauksiin perustuva toimintaolosuhteiden analysointimenetelmä.
Työssä on myös esitetty horisontaalisten ja vertikaalisten alhaalta ylöspäin puhaltavien ilmaverhoratkaisujen merkkiainemittauksilla määritetyt tiiviydet.
Tiiviysmittauksiin perustuen työn lopussa on esitetty esimerkkilaskelman avulla ilmaverhon energiansäästövaikutuksia Suomen olosuhteissa.

Ilmaverhon toimintaedellytysten ollessa kunnossa ilmaverholla voidaan saavuttaa isoissa oviaukoissa 50 - 80 %:n tiiviys.
Koehallissa korkein tiiviys mitattiin vertikaalisella alhaalta ylöspäin puhaltavalla kiertoilmaverholla (eetaac,max=80%) ja alhaisin kaksipuolisella horisontaalisella ilmaverholla (eetaac,max Ilmaverhon mitoitusparametrien (puhallusnopeus -puhalluskulma -suutinleveys) vaikutus ilmaverhon tiiviyteen oli mittauksissa enimmillään 3 %:a.
Tehdyn esimerkkilaskelman mukaan jatkuvalla puhallusnopeussäädöllä saavutetaan tyypillisessä teollisuusovikokoluokassa (5m x 5m) 5 %:n säästö säätämättömään ilmaverhoon verrattuna Suomen olosuhteissa.

Mittausten mukaan ilmaverhoilla voidaan lämpötilavaihtelu rajoittaa 1 - 2 °C:n ison oviaukon ympäristössä.
Ilmaverho synnyttää kuitenkin ilmavirtauksia ovisuulle ja ovilinjalle, jotka aiheuttavat helposti vedon tunnetta ovisuun ja ovilinjojen työpisteissä.
Ilmavirtausten nopeudet työskentelyvyöhykkeellä ovilinjalla ovat alhaisimmillaan 0.3 - 0.5 m/s.
ED:2011-03-18
INSSI record number: 41580
+ add basket
« previous | next »
INSSI