Author:Syvänen, Pekka Olavi
Title:Lämpötilan hallinta teräksen valmistuksessa ja valussa
Temperature control for steel casting
Publication type:Master's thesis
Publication year:2008
Pages:104 + [34]      Language:   fin
Department/School:Materiaalitekniikan laitos
Main subject:Metallurgia   (MT-37)
Supervisor:Holappa, Lauri
Instructor:Antola, Tuomas ; Tukiainen, Matti
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark V80     | Archive
Keywords:temperature controlling
heat loss
target temperature
continuous temperature measurement
ladle
tundish
lämpötilan hallinta
lämpöhäviö
tähtäyslämpötila
jatkuva lämpötilamittaus
senkka
väliallas
Abstract (eng): In this work the temperature control of steel melt was examined in processes following converting.
The emphasis has been placed on controlling an optimal casting temperature, which is ultimately affected by the temperature formed in the tundish.
In this work all factors, which have the most essential influence on the final development of casting temperature, are discussed.
The aim of this work has been to refine the target temperatures of steel in the ladle furnace as well as in the tundish.
This aim is achieved by doing a comprehensive empiric mapping about the development of steel temperature between the ladle furnace and tundish.

The mapping was carried out by examining the history data.
At this point, reliable temperature measurement results are of vital importance and therefore a continuous temperature measurement device was taken in use.
The continuous temperature measurement system was planned as a development work for this experiment.
The secondary aim of this work was to examine the suitability of this continuous measurement system as a part of production.

In the theoretical section heat transfer via different mechanisms from molten steel to environment in ladle and tundish was examined.
In the experimental section, when monitoring the development of the temperatures, a closer examination was carried out by taking into consideration ladle circulation significance, ladle age, the time for steel treatment, as well as cast number.
The study revealed that, on average casting process has been brought through by using a relatively high level of overheat.
This has been the result of heating in ladle furnace process, where acquired temperatures have been higher than the aim temperatures.
The largest thermal losses between ladle furnace and tundish were observed in the case where new steel ladle was taken into circulation.

In all, six test runs were carried out by using both the continuous temperature measurement device as well as a disposable one.
All test runs were successful and the results of this new continuous temperature measuring device can be considered reliable.
Abstract (fin): Tässä työssä tarkasteltiin sulan teräksen lämpötilan hallintaa konvertoinnin jälkeisissä osaprosesseissa.
Painopiste asetettiin optimaalisen valulämpötilan hallintaan, johon viime kädessä vaikuttaa lämpötilan kehittyminen välialtaassa.
Työssä on selvitetty kattavasti kaikki ne lämpötilan hallintaan vaikuttavat tekijät, jotka ovat oleellisimmin vaikuttamassa lopullisen valulämpötilan kehittymiseen.

Työn tavoitteena on ollut lämpötilaan vaikuttavien tekijöiden kartoituksen ja luotettavan lämpötilamittauksen pohjalta tarkentaa niin senkkauunin kuin välialtaankin teräslajikohtaisia tähtäyslämpötilan ohjeellisia arvoja.
Tavoite on pyritty saavuttamaan tekemällä kattava empiirinen kartoitus lämpötilan kehittymisestä välialtaalle tultaessa.
Kartoitus on tehty historiatietoja tutkimalla ja se konkretisoitui välialtaalla suoritettuun lämpötilan jatkuvatoimiseen mittaukseen.
Jatkuva lämpötilamittauslaitteisto suunniteltiin kehitystyönä tätä työtä varten ja sekundaarisena tavoitteena olikin tutkia jatkuvatoimisen lämpötilamittauslaitteiston soveltuvuutta osaksi tuotantoprosessia.

Työn teoriaosassa tehtiin selvitys siitä, miten lämpö siirtyy eri mekanismeilla sulasta teräksestä ympäristöönsä tulenkestävillä materiaaleilla vuoratussa terässenkassa ja välialtaassa.
Kokeellisessa osassa lämpötilan kehittymistä seurattaessa otettiin erikseen huomioon ja lähempään tarkasteluun edustavat teräslajityypit, senkkakierron merkitys, senkan ikä, teräksen valmistuksen vaiheiden kestoajat sekä sulatuksen järjestysnumero valussa.
Tuloksissa havaittiin, että keskimäärin valutapahtuma on saatettu läpi käyttäen verrattain korkeaa ylilämpöä.
Tämä on ollut seurausta senkkauunilla tehdyistä kuumennuksista, joissa saavutetut lämpötilat ovat olleet ohjeellisia arvoja korkeampia.
Suurimmat teräksen lämpöhäviöt välillä senkkauuni-väliallas havaittiin tapauksessa, jossa kiertoon on otettu uusi senkka.

Jatkuvalla lämpötilamittauslaitteistolla suoritettiin kaikkiaan kuusi koeajoa, joiden aikana teräksen lämpötilaa viilialtaassa seurattiin sekä yksittäisillä sondimittauksilla että jatkuvalla lämpötilamittauslaitteistolla.
Kaikki suoritetut koeajot olivat onnistuneita ja niistä saatuja tuloksia voidaan pitää luotettavina.