search query: @author Saikkonen, Antti / total: 1
reference: 1 / 1
« previous | next »
Author: | Saikkonen, Antti |
Title: | Vastapainevoimalaitoksen prosessin analysointi ja teknistaloudelliset kehittämismahdollisuudet |
Process analysis of a counter-pressure power plant and its techno-economic development prospects | |
Publication type: | Master's thesis |
Publication year: | 2005 |
Pages: | 136 s. + liitt. Language: fin |
Department/School: | Konetekniikan osasto |
Main subject: | Energiatalous ja voimalaitostekniikka (Ene-59) |
Supervisor: | Ahtila, Pekka |
Instructor: | Kontro, Rauno |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark TKK 5861 | Archive |
Abstract (eng): | One goal of energy conservation is reduction of greenhouse gases and especially cost-efficient reduction of carbon dioxide emissions. Finland should accomplish at least one quarter of the calculated total cutback need for 2010 by improving energy efficiency, as stated in the national climate strategy approved in 2001. The goals of this thesis were to describe the energy analysis process as a whole and to improve the energy efficiency of Helsinki Energy's Salmisaari B power plant by carrying out such an analysis. The energy analysis was conducted following the Ministry of Trade and Industry's 2004 guide for energy analyses and also Motiva's guide for power plant energy analysis. The analysis includes proposals for measures to achieve energy or water savings. Cost accounting for these proposals was done using 2003 as a comparison year. Values used in the calculations were based primarily on those obtained from the power plant's process monitoring system. This thesis is divided into three parts. The first part investigates means of achieving C02 emission reductions and energy savings in energy production. The second part describes energy analyses and how they are conducted. The last part consists of a practical sample of an energy analysis, in which special attention was paid to throttling controls and compressed air system inspection. Separate measurements were carried out to determine the functionality of the electrostatic precipitator and turbine. The results of the turbine's efficiency measurements were excluded from the scope of this study. 18 proposal actions for saving energy or water were found. Fuel consumption savings for 2 969 MWh/a and electricity savings for 9 083 MWh/a were found. There were no significant action proposals for reducing water consumption. |
Abstract (fin): | Energiansäästön yhtenä tavoitteena on kasvihuonekaasujen ja erityisesti hiilidioksidipäästöjen kustannustehokas vähentäminen. Suomessa energiatehokkuuden edistämisellä tulisi saavuttaa vähintään neljännes vuodelle 2010 arvioidusta kokonaisvähennystarpeesta vuonna 2001 hyväksytyn kansallisen ilmastostrategian mukaisesti. Tämän tutkimuksen tavoitteina oli kuvata energiakatselmuksen suorittaminen kokonaisuudessaan ja parantaa Helsingin Energian Salmisaaren B-voimalaitoksen energiatehokkuutta suoritetun energia-analyysin avulla. Energia-analyysi suoritettiin noudattaen kauppa- ja teollisuusministeriön energiakatselmusten yleisohjetta vuodelta 2004 sekä Motivan ohjeistusta voimalaitoksen energia-analyysin suorittamiselle. Energia-analyysissa pyritään etsimään toimenpide-ehdotuksia, joiden avulla saadaan säästöä energian tai veden kulutuksessa. Toimenpide-ehdotuksien kannattavuuslaskelmat suoritettiin käyttämällä vertailuvuotena vuotta 2003. Laskelmissa käytetyt arvot perustuivat pääosin voimalaitoksen prosessinvalvontajärjestelmästä saatuihin arvoihin. Tutkimus muodostuu osioista joissa kerrotaan C02-päästöjen vähentämisestä ja energiansäästöstä energiantuotantoalalla, energiakatselmuksista ja niiden suorittamisesta sekä suoritetusta esimerkkianalyysista. Analyysin yhteydessä kiinnitettiin erityistä huomiota erilaisiin kuristussäätöihin ja paineilmajärjestelmien katselmointiin. Sähkösuodattimelle sekä turbiinille järjestettiin erilliset mittaukset niiden toiminnallisuuden selvittämiseksi. Tässä tutkimuksessa ei ole esitetty turbiinin hyötysuhdemittausten tuloksia. Toimenpide-ehdotuksia energian tai veden säästämiseksi löytyi yhteensä 18 kappaletta. Polttoaineen kulutuksen osalta säästöä löytyi 2 969 MWh/a ja sähkön osalta 9 083 MWh/a. Vedenkulutuksen vähentämiseksi ei löytynyt merkittäviä toimenpide-ehdotuksia. |
ED: | 2005-03-29 |
INSSI record number: 28214
+ add basket
« previous | next »
INSSI