Author:Pätynen, Jukka
Title:Virtual Acoustics in Practice Rooms
Virtuaaliakustiikka musiikin harjoitustiloissa
Publication type:Master's thesis
Publication year:2007
Pages:xii + 87 s. + liitt. 8      Language:   eng
Department/School:Sähkö- ja tietoliikennetekniikan osasto
Main subject:Akustiikka ja äänenkäsittelytekniikka   (S-89)
Supervisor:Lokki, Tapio
Instructor:Salmensaari, Olli
Electronic version URL: http://urn.fi/urn:nbn:fi:tkk-010084
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark S80     | Archive
Keywords:electro-acoustics
practice room
rehearsal hall
reverberation enhancement
room acoustics
time variance
truncated hall
sähköakustiikka
harjoitushuone
saliakustiikka
jälkikaiunta
huoneakustiikan parantaminen
aikavarianssi
katkaistu sali
Abstract (eng):Due to their small size, the acoustical design of music practice rooms at music institutes presents designers with challenges and requires compromises between absorption and reverberation.
In practice, some reverberation is needed to provide support and more lively sound for the musician.
Playing in a room with plenty of absorption and very little reverberation is often uninspiring and easily causes fatigue.
On the other hand, increasing reverberation by reducing the absorption results in higher sound pressure levels.
As music teachers are exposed to these conditions for long periods of time, in the long term this can lead to hearing problems.
Similar problems are often also faced by orchestras when rehearsals are held in facilities with poor acoustical conditions.

This work investigates the use of an electro-acoustic system to improve the acoustics in practice spaces.
The electro-acoustic system uses an active method to create additional reverberation without increasing the sound pressure levels.
A second objective is to evaluate the acceptance of virtual acoustics by users in music practice spaces.

For this purpose, a prototype of an electro-acoustic system was installed in three different rooms, and the reverberation time and sound pressure level of the rooms were measured.
These case studies consist of two small classrooms and a theater hall converted to a rehearsal hall for a symphony orchestra.
For each case study, subjective opinions were collected.
The results for each room were then analyzed in terms of the feedback from the users.
The case studies show that with a careful tuning, and especially in larger spaces, a virtual acoustic system is a potential solution for improving the room acoustics of a practice room.
Abstract (fin):Musiikin harjoitusluokkien pienestä koosta johtuen akustiikkasuunnittelussa joudutaan usein tekemään kompromisseja jälkikaiunnan ja tarvittavan vaimennusmateriaalin määrän suhteen.
Harjoittelua ja instrumentin ääntä tukevaa sointia silmälläpitäen olisi suotavaa, ettei huone olisi kaiunnaltaan täysin kuiva.
Kaiuttomassa tilassa soittaminen käy nopeasti raskaaksi ja saattaa vähentää aloittelevien soittajien harjoitteluintoa.
Jälkikaiuntaa pieneen tilaan tavoiteltaessa joudutaan perinteisin akustisin menetelmin vähentämään vaimennuksen määrää, mikä puolestaan nostaa tilan äänitasoa.
Varsinkin musiikin opettajien pidemmät altistusajat hyvin kaiuntaisissa opetusluokissa saattavat johtaa kuuloon liittyviin ongelmiin.
Orkesterien tilanne on usein samankaltainen, kun harjoituksia joudutaan varsinaisen konserttisalin sijasta järjestämään akustisesti sopimattomissa tiloissa.

Tässä työssä tutkitaan sähköakustisen järjestelmän käyttöä harjoitustilojen akustiikan parantamiseksi.
Tarkoituksena on näin ollen lisätä jälkikaiuntaa nostamatta tilan äänitasoa.
Tavoitteena on myös tutkia käyttäjien suhtautumista sähköakustiikan käyttöön.

Työssä esitettyjä tutkimuksia varten sähköakustista järjestelmää kokeiltiin yhteensä kolmessa tilassa.
Tutkituista tiloista kaksi ensimmäistä olivat tyypillisiä musiikkioppilaitoksen pieniä harjoitus- ja opetusluokkia.
Kolmas tila oli monikäyttösali, johon sähköakustiikan avulla pyrittiin luomaan konserttisalin lavaa muistuttava akustiikka sinfoniaorkesterin harjoitusta varten.
Tiloissa tehtiin huoneakustisia mittauksia sekä haastateltiin käyttäjiä kyselytutkimuksella.
Tutkimusten tulosten perusteella on todettavissa, että harjoitustilojen akustiikan parantaminen sähköakustisella järjestelmällä on mahdollista.