search query: @keyword tehoviiveproili / total: 1
reference: 1 / 1
« previous | next »
Author: | Simola, Jarno |
Title: | Millimeter Wave Propagation Measurements and Modeling in Hospital Environments |
Millimetriaaltojen etenemismittaukset ja -mallinnus sairaalaympäristöissä | |
Publication type: | Master's thesis |
Publication year: | 2010 |
Pages: | 47 Language: eng |
Department/School: | Radiotieteen ja -tekniikan laitos |
Main subject: | Radiotekniikka (S-26) |
Supervisor: | Vainikainen, Pertti |
Instructor: | Kyrö, Mikko |
Electronic version URL: | http://urn.fi/URN:NBN:fi:aalto-201203131550 |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark Aalto 1395 | Archive |
Keywords: | propagation channel model path loss power delay prole radioaaltojen eteneminen 60 GHz kanavamalli etenemisvaimennus tehoviiveproili |
Abstract (eng): | Applications of wireless technologies in medical treatments have been considered for realizing portable medical equipment and remote monitoring. The 60 GHz band can theoretically offer very high data rates for such applications, but the propagation characteristics of hospital environments have not been studied. Based on preliminary measurements in a shielded room, the propagation characteristics can be expected to be different compared to regular indoor environments. As a part of a feasibility study of 60 GHz radio systems, propagation channel measurements were performed in two different hospital environments, an angiography room and an ultrasonic inspection room. In this work, path loss and delay domain analysis were made based on the measurement data. Obtained power delay profiles were used to develop delay domain channel models. The path loss of both hospital environments was found to be similar to common indoor environments. However, the delay domain characteristics of the two rooms turned out to be quite different from each other. Based on this, different models were developed for the environments. |
Abstract (fin): | Langaton tiedonsiirto voi olla hyödyksi monissa lääketieteellisissä sovelluksissa, kuten kannettavissa hoitolaitteissa ja lääkärinhoidon etävalvonnassa. 60 GHz:n taajuusalue tarjoaa teoriassa erittäin nopeaa tiedonsiirtoa kyseisiin sovelluksiin, mutta tiedonsiirtokanavan ominaisuuksia ei ole toistaiseksi tutkittu sairaalaympäristössä. Häiriösuojatussa huoneessa tehtyjen mittausten perusteella näiden ominaisuuksien voidaan olettaa poikkeavan tavallisista sisätiloista. Osana 60 GHz:n tiedonsiirtojärjestelmien soveltuvuustutkimusta suoritettiin kanavamittauksia kahdessa erilaisessa sairaalaympäristössä, angiografiahuoneessa ja ultraäänitutkimushuoneessa. Mittaustulosten perusteella analysoitiin ympäristöjen etenemisvaimennusta ja viivealueominaisuuksia. Etenemisvaimennuksen todettiin olevan molemmissa huoneissa hyvin lähellä tavallisten sisätilojen arvoja. Viivealueessa huoneiden siirtokanavat olivat kuitenkin hyvin erilaiset. Angiografiahuoneessa monitie-eteneminen oli voimakkaampaa ja tehoviivepro_ilin muoto erilainen. Tämän vuoksi molemmille ympäristöille kehitettiin oma kanavamalli. |
ED: | 2010-10-15 |
INSSI record number: 41083