Author:Veuro, Manu
Title:Vapaajäähdytysenergian varastoitumisen optimointi toimistorakennuksen lattiajäähdytyksessä
Optimizing free cooling storing in a floor cooling system of an office building
Publication type:Master's thesis
Publication year:2012
Pages:76      Language:   fin
Department/School:Energiatekniikan laitos
Main subject:LVI-tekniikka   (Ene-58)
Supervisor:Sirén, Kai
Instructor:Vuolle, Mika
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  7478   | Archive
Keywords:radiant cooling
exergy
high temperature cooling
floor cooling
simulation
optimization
säteilyjäähdytys
exergia
korkealämpötilainen jäähdytys
lattiajäähdytys
simulointi
optimointi
IDA-ICE
GenOpt
Abstract (eng): This thesis was made for YIT Kiinteistötekniikka Oy.
Basis of the thesis comes from YITs patented solution where floor heating system is combined with cooling system.
The idea is to run cooling systems return water through floor circuit.
When doing so, the temperature difference in cooling system increases, and free cooling can be stored in to floor structure.

When cooling there are several methods of heat transfer that can be used, when using floor.
On such a case operative temperature can be affected with not just indoor air temperature.
This is effective especially on those cases where radiant temperatures are high compared to air temperature.

For simulation an office building located in Vantaa was built.
Comparisons were made to compare how different kinds of heating and cooling methods affect energy consumption.
In comparisons there where both radiant and air based method and combinations of these methods.

In optimization installation parameters were optimized with GenOpt optimization software.
Optimization problem was a multi objective optimization using BGA, a multi objective optimization algorithm created for GenOpt in Aalto University.
The objective functions were the energy costs for cooling and heating and dissatisfaction of the conditions.
Decision variables were installation parameters that affect the heat transfer of the floor and the cooling power of each cooling beam.

Creating the simulation model for the patent was not easy.
All the savings were less than 1 per cent.
This is because certain amount of energy has to be brought in to building to maintain the required temperatures.
Best conditions can be created with rapidly reacting radiant systems.
Abstract (fin): Työ tehtiin YIT Kiinteistötekniikka Oy:lle.
Työn pohjana on patentoitu idea lattialämmityksen ja -jäähdytyksen yhdistämisestä ja ko. piiriin yhdistetystä jäähdytyspalkista, jolloin jäähdytysveden lämpötilaeroa saadaan kasvatettua sekä vapaajäähdytyksen avulla voidaan varata lattiamassaan jäähdytysenergiaa.

Rakennusten jäähdytyksessä voidaan hyödyntää useampaa lämmönsiirtymistapaa, kun käytetään hyväksi lattiapinta-alaa.
Tällöin operatiiviseen lämpötilaan vaikuttaminen voidaan tehdä muunkin kuin pelkän ilman lamp6tilan avulla.
Erityisesti tämä parantaa tilannetta tapauksissa, joissa säteilylämpötilat nousevat korkeiksi verrattuna ilman lämpötilaan.

Simulointia varten rakennettiin simulointimalli IDA-ICE simulointiohjelmalla Vantaalla sijaitsevasta toimistotalosta.
Simuloinnissa vertailtiin eri lämmitys- ja jäähdytystapojen vaikutuksia energiankäyttöön.
Vertailussa oli sekä säteilyyn ja ilmaan perustuvia järjestelmiä että näiden yhdistelmiä.

Optimoinnissa simulointimallin asennusparametreja optimoitiin käyttäen GenOpt optimointiohjelmaa.
Optimointi tehtiin monitavoiteoptimointina käyttäen Aalto yliopistossa GenOptiin kehitettyä BGA-optimointialgoritmia.
Tavoitefunktiona olivat lämmityksen ja jäähdytyksen energiakustannus sekä tilojen viihtyvyys.
Päätösmuuttujina olivat lattiapiirin lämmönsiirtoon vaikuttavat asennusparametrit sekä kunkin tilan jäähdytyspalkin teho.

Patentin rakentaminen IDA-ICE:n ja tämän optimointi osoittautui huomattavasti odotettua vaikeammaksi.
Säästöt eivät nousseet kustannusten eivätkä energian osalta yli yhteen prosenttiin.
Tämä johtui siitä, että rakennukseen on joka tapauksessa tuotava tietty määrä lämpö- ja jäähdytysenergiaa, jotta halutut lämpötilatasot säilyisivät.
Tilojen viihtyvyys kuitenkin parani, kun malliin asetettiin optimoidut arvot.
Tilojen viihtyvyys on parhaimmillaan, kun yhtäaikaisesti hallitaan kumpaakin operatiivisen lämpötilan elementtiä.
Mikäli tilan lämpötilan olisi annettu laskea yöaikaan, olisi massaan varaaminen ollut tehokkaampaa.
Nopeasti reagoiva säteilylämmitys ja -jäähdytys pienentävät tyytymättömien osuutta.