Author:Orkola, Pirita
Title:Höyrykattilan syöttöveden ja palamisilman esilämmittimien mitoituksen optimointi
Steam boiler feed water and air preheater dimensioning optimization
Publication type:Master's thesis
Publication year:2011
Pages:99 s. + liitt. 5      Language:   fin
Department/School:Energiatekniikan laitos
Main subject:Energiatalous ja voimalaitostekniikka   (Ene-59)
Supervisor:Ahtila, Pekka
Instructor:Kaarlonen, Kaarlo
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  4729   | Archive
Keywords:feedwater preheating
combustion air preheating
process simulation
steam coil air heater
optimization
syöttöveden esilämmitys
palamisilman esilämmitys
prosessisimulointi
höyryluvo
optimointi
Abstract (eng): This master's thesis studies how the modifications in the power plant's feed water and combustion air preheating systems affect the power plant process.
The calculation is carried out on condensing and district heat power plant firing coal and biofuel.
The calculations are done with the help of Sweco Industry Oy's process simulator Powsim.

First part of this thesis consists of literature review including the principles of feed water and combustion air preheating systems, power plant efficiency and theory of heat transfer and heat exchanger dimensioning.
The process simulator Powsim is introduced in general and its dimensioning principles regarding the heat exchangers are presented.

The second part of the thesis is focused on the experimental studies of the power plant process.
Effects of the feed water temperature and steam coil air heater usage are investigated by calculating different cases.
Models and dimensioning parameters used in process simulator are introduced and execution of the calculation is explained in detail.
Results derived from the process calculations are fuel input, net electrical output and heat exchanger conductance.
The economic impacts of the modifications are calculated to estimate the optimum solution.
The limiting factors occurred during calculation are also investigated.

The results of this survey implied that using steam coil air heater in preheating the combustion air over its minimum level was viable from process efficiency point of view.
The feed water temperature at its highest level was most beneficial for district heat power plant.
The reheat process efficiency of condensing power plant interfered with the examination of the feed water temperature variation.
The limiting factors appeared in exceeding the defined minimum temperature differences restricting the further calculations.
The total costs of each case on both power plant types depended on variable costs and investment costs.
The total cost optimum varied with power plant type and fuel.
Abstract (fin): Tässä diplomityössä tutkitaan prosessisimulointiohjelman avulla, miten muutokset syöttöveden ja palamisilman esilämmityksessä vaikuttavat voimalaitosprosessiin.
Tarkastelu suoritetaan lauhde- ja kaukolämpölaitoksille kivihiilellä ja biopolttoaineella.

Työn ensimmäisessä osassa käydään läpi voimalaitoksen syöttöveden ja palamisilman esilämmitysjärjestelmien toimintaperiaatteet.
Lisäksi käsitellään työssä tutkittavien lämmönsiirrinkomponenttien mitoituksen ja lämmönsiirron teoriaa.
Laskennassa käytettävän Sweeo Industry Oy:n prosessisimulointiohjelma Powsim:n toimintaa esitellään yleisellä tasolla sekä työssä tarkasteltavien komponenttien kannalta.

Työn laskennallisessa osassa esitellään optimointilaskennassa käytettävät mallit, parametrit sekä laskennan toteutus.
Laskennan vaikutuksia voimalaitosprosessiin tutkitaan polttoainetehon, nettosähkötehon sekä lämpöpintojen konduktanssien muutosten avulla.
Työssä tarkastellaan eri ratkaisujen taloudellista hyötyä vertailemalla lämpöpintojen ja voimalaitoksen investointikustannuksista sekä muuttuvista kustannuksista koostuvia kokonaiskustannuksia.
Lisäksi tutkitaan, millaisia rajoittavia tekijöitä laskennan yhteydessä tulee ilmi eri polttoaineiden ja voimalaitostyyppien kesken.

Tutkimuksesta kävi ilmi, että höyryluvon käyttäminen palamisilman esilämmittämiseksi vähimmäislämpötilaa korkeammaksi oli kannattavaa prosessin hyötysuhteen näkökulmasta.
Syöttöveden lämpötilan nostaminen tutkituista lämpötilatasoista korkeimmalle oli prosessin kannalta hyödyllisintä kaukolämpölaitoksen tapauksessa.
Lauhdelaitoksella välitulistusprosessin toiminta vaikeutti syöttöveden lämpötilan vaikutusten arviointia.
Rajoittavat tekijät tulivat esiin asetettujen minimilämpötilaerojen ylittymisenä eri tilanteissa eri polttoaineilla, mikä vähensi laskentatapausten määrää.
Taloudellisessa tarkastelussa huomattiin optimiratkaisun vaihtelevan voimalaitostyypistä ja -polttoaineesta riippuen.
ED:2011-06-09
INSSI record number: 42131