search query: @supervisor Korhonen, Timo / total: 105
reference: 17 / 105
« previous | next »
Author:Waldén, Jan
Title:Compatibility of multiple vendor Dense Wavelength Division Multiplexing system
Useampien valmistajien DWDM järjestelmien yhteensopivuus
Publication type:Master's thesis
Publication year:2010
Pages:x + 80 s. + liitt. 4      Language:   eng
Department/School:Elektroniikan, tietoliikenteen ja automaation tiedekunta
Main subject:Tietoliikennetekniikka   (S-72)
Supervisor:Korhonen, Timo
Instructor:Heino, Juha
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  1533   | Archive
Keywords:DWDM
OSNR
FEC
foreign wavelength
modulation schemes
optical amplifier
chromatic dispercion
polarisation modulation dispersion
nonlinearities in optical communication systems


optinen signaalikohinasuhde
FEC virheenkorjausmenetelmä
ulkoinen aallonpituus
modulaatio
optinen vahvistin
kromaattinen dispersio
polarisaatio modulaatio dispersio
epälineaarisuudet optisissa viestintäjärjestelmissä
Abstract (eng): The whole telecommunication market is changing fast with the amount of data that is handled by the backbone network increasing rapidly.
Drivers to the capacity need include high rate-point-to- point connections,nove1 streaming applications, as advanced, Video on Demand (VoD), High definition Television (HDTV) networks Virtual Local Area Network (VLAN).The need for backbone capacity has tripled in the last three years, mainly due to transit traffic to other operators.

This demand for high capacities in the network sets pressure on the backbone network: it has to be flexible and future: proof.
Here flexibility refers to the interoperability between different vendor equipment Dense Wavelength Division Multiplexing (DWDM) systems.
Networks are not heterogeneous in their need therefore it makes sense to use different solutions and/or even vendors in separate areas based on uneven traffic volume distribution.
When transmitting an optical signal between DWDM systems manufactured by different vendors, there are a few things that need to be considered.
First, although the OTN (Optical Transport Network) frame is standardised, transponders from different vendors do not work together as a rule.
There are several technical reasons for this: vendors often have developed and implemented their own Forward Error Correction (FEC).
Optical technology dependent aspects are not defined for the line interfaces in order to support some freedom in technology changes.

According to G.709, the Optical channel Data Unit ODU experimental overhead is allocated to be used by vendors or operators to support an application that requires ODU overhead support in the network.
For instance, the optical power is left unspecified because it has an optimum value for a specific technical configuration, the limiting effect of optical signal to noise ratio, what kind of modulation is used.

In order to test the interoperability, a set of test was performed with vendor D DWDM system transmitting a wavelength into a DWDM system from vendor C.
The tests show that the chromatic dispersion is a challenge because of the different dispersion compensation solutions.
A DWDM system that uses electronic dispersion compensation on each channel will achieve a longer span length compared to a system using dispersion compensation fibres on the line.
This limits the distance for transponders that has to rely on dispersion compensation module implemented on the DWDM line.

An investigation of the ITU-T standards (G.709, G.959.1 and G.698.1) concerning interoperability shows that the DWDM interfaces are standardised for metro DWDM networks without line-amplification.
The long haul networks have intentionally not been very strictly specified in order to give an opportunity for different technology solutions to be developed.
Abstract (fin): Televiestintä muuttuu tänä päivänä nopeasti.
Tietomäärä, joka siirretään operaattoreiden runkoverkossa, kasvaa koko ajan.
Kapasiteetin kasvun moottoreina ovat toimipisteiden välillä olevat SDH- ja MPLS-yhteydet sekä nopeat streaming-tyyppiset palvelut, kuten teräväpiirtotelevisio ja tilausvideopalvelut.
Virtuaalisten verkkojen ja päätelaitteiden kehitys on myös huomioitava.
Verkkokapasiteetin tarve on kasvanut yli kolminkertaiseksi kolmen viimeisimmän vuoden aikana, mikä asettaa suuria vaatimuksia runkoverkkojen kapasiteetille ja laitteistojen yhteensopivuudelle.
Koska kapasiteetin tarve on heterogeeninen verkon eri osissa, voi olla järkevää käyttää saman verkon eri osissa erilaisia ratkaisuja.

Vaikka optinen siirtoverkko on standardoitu, eri valmistajien aallonpituusmuuntimet eivät ole standardoituja niin, että niitä pystyisi käyttämään linjaportit vastakkain.
Syitä tähän voi löytyä siitä, että valmistajat ovat kehittäneet oman FEC (Forward Error Correction) - menetelmän tai valmistajat jättävät hyödyntämättä tai omaehtoisesti täydentävät joitakin optisen kehysrakenteen mahdollisuuksia.
Fysikaaliset muuttujat, jotka voivat vaikuttaa yhteensopivuuteen, ovat signaalin optinen taso, optinen signaalikohinasuhde, dispersio ja kanavien ylikuuluminen sekä epälineaarisuuksien vaikutus.
Suurilla kapasiteeteilla fysikaaliset muuttujat, kuten Polarisaatio modulaatio dispersio ja ristivaihemodulaatio vaikuttavat siihen, mikä modulaatiomenetelmistä valitaan.

Aallonpituuksien käyttöönottomenetelmä vaihtelee.
Yhden laitevalmistajan toimintaperiaate on, että järjestelmä automaattisesti säätää tarvittavat optiset tasot optimoidakseen optista signaalikohinasuhdetta, kun toisen valmistajan säätö tehdään säätämällä jokaisen kanavan lähetysteho erikseen.
Yksi DWDM -järjestelmän rajoittavimmista tekijöistä on kromaattinen dispersio.
Kromaattisen dispersion kompensaatiomenetelmä on rajoittava tekijä.

Mikäli on käytetty kanavakohtaista dispersiokompensaatiota, hypyn pituus voi olla niin pitkä, etteivät dispersiokompensaatiomoduulit linkin päissä riitä kompensoimaan ulkoiselle aallonpituudelle muodostunutta dispersiota riittävän paljon.
Ulkoisen aallonpituuden saavutettava etäisyys kuitudispersiokompensaatiolla on riippuvainen käytetyistä dispersiokompensaatiomoduulien arvoista.
Näitä voidaan vain lisätä linkin molempiin päihin.
Tutkiessa standardit (G.959.1 ja G.698.1), kävi ilmi että metro DWDM verkossa, jossa ei käytetä linja-vahvistimia, DWDM rajapinnat on tarkkaan spesifioitu.
Metro DWDM:ssä käytetään Optical Transport Unitia (OTU) joka on osa G.709 kehysrakennetta.
Optical Transport Network OTN -standardissa on jätetty tilaa teknologian kehitystä varten.
ED:2010-09-13
INSSI record number: 40773
+ add basket
« previous | next »
INSSI