search query: @instructor Virtanen, Juha / total: 11
reference: 1 / 11
« previous | next »
Author:Virtanen, Seppo Ilkka
Title:Continuous Impedance Measurement as a Signal Quality Indicator in Electroencephalography
Jatkuva impedanssimittaus aivosähkökäyrän laadun mittarina
Publication type:Master's thesis
Publication year:2009
Pages:55 (+9)      Language:   eng
Department/School:Informaatio- ja luonnontieteiden tiedekunta
Main subject:Lääketieteellinen tekniikka   (Tfy-99)
Supervisor:Meriläinen, Pekka
Instructor:Virtanen, Juha
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark TF80     | Archive
Keywords:EEG
sedation
sleep
impedance
artifact
EEG
sedaatio
uni
impedanssi
artefaktat
Abstract (eng): In intensive care unit (ICU) anxiety and pain of seriously ill patients is often relieved with sedative drugs.
Optimal level of sedation is important for quick recovery.
Despite the induced sedation natural sleep is also important for recovery in the ICU.
Depth of sedation is assessed with observational scales, which lack objectivity and are not applicable with deeply sedated patients.
Forehead-electroencephalography -based depth-of-anesthesia -parameters from surgical anesthesia are being adapted for assessing the level of consciousness of patient in the ICU.
Voluntary patient movements and care procedures in the ICU introduce new sources of artifacts in the electroencephalography (EEG) signal, giving rise to need for new artifact detection techniques.

We investigated possibilities to use continuous impedance measurement as a signal quality indicator for frontal EEG.
We measured impedance at 32-kHz frequency from the same electrodes as the EEG.
Head motion was recorded with an acceleration transducer on the forehead.
With impedance measurement we were able to detect artifacts related to head motion, electrode contacts, muscle movements, blinks, and eye movements.
This enabled discarding of contaminated EEG segments.
Subtracting of the artifactual EEG was not feasible, because of the differences between EEG and impedance waveforms.
Slow and narrow horizontal eye movements were poorly detected by impedance.
In order to compensate this shortcoming, two new EEG-based artifact detection methods were developed utilizing frequencies below normal EEG band (0.05 - 0.5 Hz).
Our preliminary results with only few subjects were promising, but studies with larger population to prove the feasibility.
Abstract (fin): Teho-osastolla vakavasti sairaiden potilaiden kipuja ja ahdistuneisuutta helpotetaan usein rauhoittavilla lääkkeillä.
Rauhoituksen (sedaation) oikea syvyys on tärkeää paranemiselle.
Huolimatta syvästäkin rauhoituksesta luonnollinen uni on myös tärkeää paranemiselle teho-osastolla.
Rauhoituksen syvyyttä arvioidaan havainnointiin perustuvilla kliinisillä menetelmillä, joiden tulokset voivat riippua havaintojen tekijästä ja jotka eivät sovellu syvästi rauhoitettujen potilaiden arviointiin.
Otsan aivosähkökäyrän (EEG) mittaukseen perustuvia leikkausanestesian syvyyden mittausparametreja ollaan soveltamassa tehopotilaiden tajunnantilan arvioon.
Potilaiden liikkeet ja hoitotoimenpiteet teho-osastolla aiheuttavat uusia virhelähteitä EEG-signaaliin, joiden havaitsemiseen tarvitaan uudenlaisia tekniikoita.

Selvitimme mahdollisuutta käyttää jatkuvaa impedanssimittausta otsalta mitatun EEG:n laadun mittarina.
Impedanssi mitattiin 32 kHz taajuudella samoista elektrodeista EEG:n kanssa.
Pään liikkeitä mitattiin otsalta kiihtyvyysanturilla.
Onnistuimme havaitsemaan impedanssin avulla pään liikkeisiin, elektrodikontakteihin, lihassupistuksiin, silmänräpytykseen ja - liikkeisiin liittyvät EEG artefaktit.
Tämä mahdollisti virheellisten EEG jaksojen hylkäämisen.
Artefaktien poistaminen EEG:stä ei ollut mahdollista, koska virheet näkyivät EEG:ssä ja impedanssissa erilaisina.
Impedanssin suorituskyky hitaiden ja kapeiden silmänliikkeiden havaitsemisessa oli huono.
Tätä puutetta paikkaamaan kehitettiin kaksi uutta EEG:hen perustuvaa havaitsemismenetelmää normaalin EEG:n alapuolista taajuuskaistaa (0,05 - 0,5 Hz) hyödyntäen.
Alustavat tulokset muutamilla potilailla olivat lupaavia, mutta tutkimuksia isommilla potilasmäärillä tarvitaan menetelmien toimivuuden osoittamiseen.
ED:2010-01-21