search query: @keyword maasulku / total: 11
reference: 4 / 11
« previous | next »
Author:Tervo, Jori
Title:Use-cases of phase-earthing circuit breakers in self-healing power networks
Vaiheenmaadoituskatkaisijan käyttömahdollisuudet itsestään korjaavissa sähköverkoissa
Publication type:Master's thesis
Publication year:2012
Pages:x + 89 s. + liitt. 16      Language:   eng
Department/School:Sähkötekniikan laitos
Main subject:Sähköverkot ja suurjännitetekniikka   (S-18)
Supervisor:Lehtonen, Matti
Instructor:Saarinen, Jarmo
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  1507   | Archive
Keywords:phase-earthing
shunt circuit-breaker
earth fault
earth fault protection
automatic reclocing
Petersen coil
zone concept
vaiheenmaadoitus
vaiheenmaadoituskatkaisija
maasulku
maasulkusuojaus
jälleenkytkentä
kompensointikela
vyöhykekonsepti
Abstract (eng): The topic of this thesis is the phase-earthing method, which can be used to reduce the number of high speed automatic reclosing functions.
In practice, the faulty phase is connected to the ground at a feeding substation for a few tenths of a second.
If the faulty phase can be earthed for a longer time, it might be possible to maintain electricity distribution in permanent fault situations.

The thesis discusses the phase-earthing method for example from safety regulations and earth fault protection points of view.
The safety regulations determine the maximum fault duration.
The duration depends on earth potential rise in the network.
For this reason, the earth potential rise also determines the maximum phase-earthing time.
Especially, the introduction of a prototype phase-earthing system is discussed.
It is studied how earth fault protection setting could be modified in order that earth fault protection would function properly.
In this task, disturbance recordings that were recorded in field tests have been examined.
The maximum residual current is approximated by means of electro technical calculations.

The phase-earthing method is also evaluated from the economic point of view.
Interruption cost savings between a compensation coil and a phase-earthing circuit breaker are compared.
In the comparison, a certain medium voltage network is used and it is analysed by using LuoVa reliability analysis software.

In addition, the use of the phase-earthing method is studied from the zone concept point of view.
The concept enables fast fault localization and fast fault isolation.
These features are achieved by utilizing new protection features and adding protection and switching devices in network.
In the future, this kind of system might be able to isolate faults and restore power independently.
The benefit of the phase-earthing method in this kind of self-healing network is estimated by using LuoVa reliability analysis software.
Abstract (fin): Tässä työssä tutkitaan vaiheenmaadoitusmenetelmää, jota voidaan käyttää vähentämään pikajällenkytkentöjen lukumäärää.
Käytännössä viallinen vaihe kytketään maahan syöttävällä sähköasemalla.
Jos viallinen vaihe voidaan maadoittaa pidemmäksi aikaa, voisi olla mahdollista ylläpitää sähkönjakelua pysyvissä vikatilanteissa.

Tässä työssä vaiheenmaadoitusmenetelmää tarkastellaan esimerkiksi turvallisuusmääräysten ja maasulkusuojauksen näkökulmasta.
Turvallisuusmääräykset määräävät suurimman sallitun vian kestoajan.
Kyseinen aika on riippuvainen verkon maadoitusjännitteistä.
Näin ollen maapotentiaalin nousu määrää myös vaiheenmaadoitusajan.

Erityisesti on tutkittu prototyyppi vaiheenmaadoitusjärjestelmän käyttöönottoa.
Työssä tarkastellaan kuinka maasulkusuojausasetteluja tulisi muuttaa, jotta suojaus toimisi oikealla tavalla.
Tätä varten kenttäkokeista saatuja häiriötallenteita on tutkittu.
Maksimi jäännösvikavirran suuruus on arvioitu sähköteknisillä laskelmilla.

Vaiheenmaadoitusmenetelmää tarkastellaan myös taloudellisesta näkökulmasta.
Kompensointikelan ja vaiheenmaadoituskatkaisijan keskeytyskustannussaastoja on vertailtu.
Tämä vertailu on tehty tietyssä keskijänniteverkossa käyttämällä LuoVa luotettavuusanalyysiohjelmistoa.

Lisäksi vaiheenmaadoitusmenetelmän käyttöä tarkastellaan vyöhykekonseptin näkökulmasta.
Tämä konsepti mahdollistaa nopean vian paikannuksen ja nopean vian erotuksen.
Nämä ominaisuudet aikaansaadaan hyödyntämällä uusia suojausominaisuuksia ja lisäämällä verkkoon suojaus- ja kytkinlaitteita.

Tulevaisuudessa tällainen järjestelmä voi pystyä automaattiseen vian erotukseen ja sähkönsyötön palauttamiseen.
Vaiheenmaadoitusmenetelmän hyötyä tämänkaltaisessa itsestään korjautuvassa verkossa on arvioitu käyttämällä LuoVa luotettavuusanalyysiohjelmistoa.
ED:2012-07-05
INSSI record number: 45001
+ add basket
« previous | next »