Author:Juvani, Jani
Title:Avolouhoksen vedenpoisto maanalaista pumppaamotilaa hyödyntäen
Dewatering open pit mine by exploiting underground pumping station
Publication type:Master's thesis
Publication year:2013
Pages:95 + [6]      Language:   fin
Department/School:Rakennustekniikan laitos
Main subject:Kalliorakentaminen   (Rak-32)
Supervisor:Rinne, Mikael
Instructor:Kuula, Harri
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto     | Archive
Keywords:open pit mine
dewatering
pumping system
underground
drainage
avolouhos
vedenpoisto
pumppausjärjestelmä
maanalainen
kuivatus
Abstract (eng): Rainfall, surface run-off and groundwater flow cause a constant accumulation of water in an open pit mine which is why dewatering is one of the most important factors effecting mining operations.
Even though the entire production chain depends on the functionality of dewatering, significant investments in the design of dewatering are currently still lacking.
In addition to dewatering, benefits such as decreased pumping volume and stability improvement in the pit walls caused by preventing surface run-off and lowering the groundwater table are not examined sufficiently in conjunction with dewatering.

The aim of this thesis was to examine which factors affect the design and dimensioning of an underground dewatering system in an open pit mine.
This study was used to determine how the pumping system has to be selected and what has to be taken into account when considering the location of the underground pumping station in the case of the Särkijärvi open pit mine.
In addition, the feasibility of the Särkijärvi pumping system and the underground pumping station as well as possible drainage methods was considered.

Dewatering methods and source data obtained from mine visits in Ihalainen and Pyhäsalmi were used for the purposes of this study.
Knowledge from pump manufacturers Sulzer Pumps Finland Plc and Xylem Water Solutions Finland Plc was used to determine the pumping system and the parameters that influence the selection of the pumping system.
The effect of rainfall on the pumping volume in an open pit mine was examined using monthly rainfall data obtained from the Finnish Meteorological Institute.

Based on the results of this study, the discharge head and the solid content of the mine water have a major effect on the selection of the pumping system.
When determining the location of the underground pumping station, maintenance access had to take into account the expansion plan of the Särkijärvi open pit mine.
The rock quality of the area was another important factor when determining the location of the underground pumping station.
Preventing the surface run-off to the open pit mine was discovered to be generally necessary, although benefits from lowering the groundwater table in the pit walls have to be considered individually according to each case.
Abstract (fin): Avolouhoksiin kertyy vettä jatkuvasti sadannan, pintavalunnan ja pohjaveden virtauksen vaikutuksesta, minkä takia avolouhoksen vedenpoisto on yksi tärkeimmistä louhostoimintaan vaikuttavista tekijöistä.
Koko tuotantoketju on riippuvainen vedenpoiston toimivuudesta, mutta silti sen suunnitteluun ei panosteta merkittävästi tänä paivana.
Vedenpoiston lisäksi pintavalunnan ehkäisemisellä ja pohjaveden alentamisella saavutettavia hyötyjä avolouhoksen pumppauksessa ja seinämästabiliteetissa ei tarkastella riittävästi louhoksen vedenpoiston yhteydessä.

Diplomityön tavoite oli selvittää avolouhoksen maanalaisen vedenpoistojärjestelmän suunnitteluun ja mitoitukseen vaikuttavat tekijät.
Selvityksen avulla tutkittiin, miten case-kohteena olleen Siilinjärven Särkijärven avolouhoksen pumppausjärjestelmä on valittava ja mitä tekijöitä on huomioitava sijoitettaessa pääpumppaamo maan alle.
Lisäksi tarkasteltiin Särkijärven pumppausjärjestelmän ja maanalaisen pumppaamotilan toteutettavuutta sekä pohdittiin vedenpoiston yhteydessä tehtäviä mahdollisia avolouhoksen kuivatusratkaisuja.

Tutkimuksen apuna käytettiin Ihalaisen ja Pyhäsalmen kaivosvierailuilta saatuja tietoja ja vedenpoiston ratkaisumalleja.
Pumppuvalmistajista Sulzer Pumps Finland Oy:n ja Xylem Water Solutions Suomi Oy:n henkilöstön kanssa pohdittiin pumppausjärjestelmän valintaa ja siinä huomioitavia parametreja.
Sademäärän vaikutusta avolouhosten pumppausmäärään tutkittiin Ilmatieteen laitokselta saatujen kuukausittaisten sademäärätietojen avulla.

Tutkimuksen tuloksena havaittiin pumppausjärjestelmän valintaan vaikuttavan eniten louhosveden nostokorkeus ja kiintoaineksen ominaisuudet.
Maanalaisen pumppaamotilan sijoittamisen kannalta jouduttiin kiinnittämään erityistä huomiota kulkuyhteyksien järjestämiseen Särkijärven avolouhoksen laajentumissuunnitelman takia.
Alueen kalliolaatu oli toinen hyvin vaikuttava tekijä määritettäessä pumppaamotilan sijoituspaikkaa.
Pintavalunnan estäminen avolouhokseen todettiin olevan yleisesti tarpeellinen, mutta louhosseinämien pohjavedenpinnan alentamisen tuomat hyödyt on tarpeen määrittää kaivoskohtaisesti.