search query: @keyword NMR / total: 12
reference: 8 / 12
Author: | Renvall, Ville |
Title: | Physical simulation of blood oxygen level variation in functional magnetic resonance imaging |
Veren hapetustason muutosten fysikaalinen simulointi toiminnallisessa magneettikuvauksessa | |
Publication type: | Master's thesis |
Publication year: | 2004 |
Pages: | xiv + 60 s. + liitt. 10 Language: eng |
Department/School: | Teknillisen fysiikan ja matematiikan osasto |
Main subject: | Lääketieteellinen tekniikka (Tfy-99) |
Supervisor: | Katila, Toivo |
Instructor: | Joensuu, Raimo |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark TF80 | Archive |
Keywords: | fMRI MRI NMR quality assurance simulation laadunvarmennus simulointi |
Abstract (eng): | Functional magnetic resonance imaging is a popular method in brain research. It can pinpoint secondary metabolic activity following electrical Signalling of neurons. Typically, the extent of an identified activation is several voxels while some of them are activated more than others. The purpose of the current study was to develop a method and device, which would signify whether an activation of certain intensity in a specified voxel of certain size determines the metabolism of the tissue represented by the voxel or does it represent the residual spread intensity of another voxel. In practise, this could clarify the scientific terminology where activations currently described as large could be characterised more precisely in terms of intensity and spread. The work consisted of designing and constructing a phantom system and the accompanying signalling system. The systems were tested and a methodology for the spatial location assurance was developed. The work was done in the Advanced Magnetic Imaging Centre of Helsinki University of Technology. |
Abstract (fin): | Toiminnallinen magneettikuvaus on paljon käytetty menetelmä aivotutkimuksessa. Sillä voidaan paikallistaa esimerkiksi hermosolujen sähköisen viestimisen seurauksena tapahtuvaa aineenvaihduntaa. Havaitun ilmiön tilavuus on tavallisesti laajuudeltaan useita tilavuuskuvan alkioita ja ilmiön voimakkuus vaihtelee tilavuusalkiosta toiseen. Tämän tutkimuksen tarkoitus oli kehittää menetelmä ja laitteisto, joilla voidaan selvittää, josko on mahdollista, että. tietyssä tilavuuskuvan alkiossa havaittu aktivaatiointensiteetti voi syntyä vain sitä vastaavassa näytetilavuudessa. Vaihtoehtona on ilmiön intensiteetin leviäminen ympäröiviin kuva-alkioihin siten, että signaalilähde, jonka tulkiltaan olevan laaja, voikin olla pienikokoinen ja voimakas. Käytännössä menetelmällä voidaan selventäviä suuriksi luonnehdittujen aktivaatioiden luokittelua laajoihin ja voimakkaisiin. Työ käsitti mittausfantomin ja sen ohjausjärjestelmän suunnittelun ja toteutuksen. Laitteet testattiin ja kehitettiin menetelmä toiminnallisen magneettikuvauksen paikkatarkkuuden varmistamiseen. Työ tehtiin Teknillisen korkeakoulun AMI-keskuksessa. |
ED: | 2004-07-13 |
INSSI record number: 25424
+ add basket
INSSI