search query: @instructor Pokki, Juha-Pekka / total: 12
reference: 4 / 12
« previous | next »
Author:Creati, Arianna
Title:Ternary liquid-liquid equilibrium measurements of systems consisting of water, furfural and solvent
Publication type:Final Project work
Publication year:2014
Pages:v + 64      Language:   eng
Department/School:Kemian tekniikan korkeakoulu
Main subject:Chemical Technology   (KE3004)
Supervisor:Alopaeus, Ville
Instructor:Pokki, Juha-Pekka
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201408272514
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  2122   | Archive
Keywords:liquid-liquid equilibrium
furfural water solvent
ternary system
binary system.
Abstract (eng):This thesis presents experimental liquid-liquid equilibrium of ternary systems of furfural, water and solvent.
This study belongs to a large project on computational aspects of phase equilibrium and experimental phase equilibrium measurements on biorefinery concepts funded by Academy of Finland (decision ID 253336).
Liquid-liquid equilibrium (LLE) and selection of solvent are important in modelling extraction process because the components typically are highly diluted in water.

Within the scope of the project the review on existing measurements on liquid-liquid equilibria revealed that only 4-Methyl-2-pentanone (methyl isobutyl ketone) and 2-methyl-2-butanol (tert-pentanol) had some ternary LLE at room temperature with furfural and water. 2-Butanol had no ternary LLE with furfural and water.

The experiments carried out with a system of thermostated cells equipped with mixer.
The systems under investigation were MIBK + furfural + water, tert-pentanol + furfural + water and 2-butanol + furfural + water from room temperature up to 70 C.

Acetone was used as an internal standard technique and samples were analysed by using a gas chromatograph (GC) equipped with non-polar GC column to the flame ionisation detector (FID) and polar GC column to the thermal conductivity detector (TCD) in parallel.
For every system the samples were taken with the help of a syringe.
Binary samples were repeated several times at several temperatures.
The ternary systems were measured at three isotherms.
The MIBK + furfural + water system was the reference system and the trend of the points was very close to the literature data.
For the system tert - pentanol + furfural + water it was observed the same result.
For the system 2-butanol + furfural + water there were no literature data.
This system was the most challenging to measure because of a long settling time.
In addition the system exhibits two liquid-liquid regions which means that it is not suitable as a solvent for extraction purpose.