search query: @keyword testaus / total: 122
reference: 14 / 122
« previous | next »
Author:Näsilä, Antti
Title:Validation of Aalto-1 Spectral Imager Technology to Space Environment
Aalto-1 -satelliitin spektrikamerateknologian validointi avaruusympäristöön
Publication type:Master's thesis
Publication year:2013
Pages:x + 67 s. + liitt. 13      Language:   eng
Department/School:Radiotieteen ja -tekniikan laitos
Main subject:Avaruustekniikka   (ETA3001)
Supervisor:Hallikainen, Martti
Instructor:Viherkanto, Kai
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201307127193
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  1248   | Archive
Keywords:Fabry-Perot Interferometer
space
qualification
Fabry-Perot Interferometri
Aalto-1
avaruus
testaus
Abstract (eng):The goal of this work was the successful space qualification of the piezo-actuated Fabry-Perot Interferometer module for the Aalto-1 Spectral Imager, which is designed to be the main payload of the Aalto-1 nanosatellite.
To accomplish this goal, series of tests were designed and implemented.
The tests included thermal cycling in temperature chamber, vibration and shock tests, frequency and step response tests in low vacuum and finally a series of hard vacuum tests in thermal vacuum chamber.
The design specifications related to performance of the Fabry-Perot module were set for transmission (0.1-0.3), spectral resolution (10-30 nm), spectral stability (0.2 nm/°C) and tuning speed (<30 ms).
In addition to this, there were also specifications for the temperature (-45-65°C) and launch vehicle environment.
After some re-designs, The Fabry-Perot module passed all the qualification tests, and the design specifications were met, thus the module can be qualified for space environment.
Abstract (fin):Tässä työssä suoritettiin Aalto-1 -nanosatelliitin spektrikameran pietso-aktuoidun Fabry-Perot Interferometrin avaruuskvalifiointi.
Spektrikamera tulee olemaan Aalto-1 -satelliitin päähyötykuorma.
Avaruuskvalifiointia varten suunniteltiin ja toteutettiin avaruustestikampanja, joka sisälsi lämpösyklauksen lämpökaapissa, tärinä- ja shokkitestit, taajuus- ja askelvasteiden mittaukset tyhjiössä.
Lopuksi suoritettiin myös sarja testejä termovakuumikammiossa.
Fabry-Perot Interferometrin suorituskyvylle asetettiin seuraavat spesifikaatiot: läpäisy 0.1-0.3, spektraalinen resoluutio 10-30 nm, spektrinen vakaus 0.2 nm/°C sekä säätönopeus < 30 ms.
Tämän lisäksi vaaditiin myös selviytymistä lämpötila- (-45-65°C) ja laukaisuympäristöistä.
Muutamien korjausten jälkeen Fabry-Perot -moduuli läpäisi kaikki kvalifikaatiotestit ja spesifikaatiot täytettiin, joten moduuli on kvalifioitu avaruusolosuhteisiin onnistuneesti.