search query: @instructor Jänkälä, Kalle / total: 13
reference: 8 / 13
« previous | next »
Author:Loimula, Mikko
Title:Evaluation of Fire Risks for a Room in the Loviisa Nuclear Power Plant Using Two Methods
Huonetilan paloriskien arviointi Loviisan ydinvoimalaitoksella kahta menetelmää käyttäen
Publication type:Master's thesis
Publication year:2009
Pages:86      Language:   eng
Department/School:Informaatio- ja luonnontieteiden tiedekunta
Degree programme:Teknillisen fysiikan ja matematiikan tutkinto-ohjelma
Main subject:Sovellettu matematiikka   (Mat-2)
Supervisor:Salo, Ahti
Instructor:Jänkälä, Kalle
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark T80     | Archive
Keywords:PSA
PRA
fira risk
fire frequency
NUREG/CR-6850
demineralization plant
PSA
PRA
paloriski
palotaajuus
NUREG/CR-6850
suolanpoistolaitos
Abstract (eng): Fire initiated events account for a significant part of the core damage frequency in the nuclear power plants.
In the Loviisa nuclear power plant the fire risks account for 15 % of the total risk of core damage.
Therefore, the analysis of fire risks plays an important role in minimizing the risks related to the operation of nuclear power plants.

In this thesis, two methods are introduced and used to analyze fire risks for a room in the Loviisa nuclear power plant: the Loviisa fire PRA method and the NUREG/CR-6850 method developed by the U.S.
NRC.
The main results are the fire frequency and the fire risk coming from the room under inspection.
The compositions of the fire risk according to both methods are also presented.

Both methods are evaluated according to their results they give and to the required workload.
Based on this evaluation recommendations, are given for the possible future use of these methods as a part of the fire risk analysis of the Loviisa nuclear power plant.

It was found out that both methods produce similar results for the fire frequency.
This was probably due to fundamentally similar approximations for both methods.

Both methods also resulted in similar fire risks for the room under inspection.
One of the main differences between these methods was that NUREG/CR-6850 included tools to evaluate the probabilities of an erroneous automation signal due to automation cable fires, unlike the Loviisa fire PRA method.
Abstract (fin): Tulipaloista johtuvat onnettomuudet muodostavat merkittävän osan ydinvoimaloiden reaktorisydämen vaurioriskistä.
Loviisan ydinvoimalassa paloriskit aiheuttavat noin 15 % laitoksen sydänvaurioriskistä.
Näin ollen paloriskien analysoinnilla on merkittävä rooli ydinvoimaloihin liittyvien riskien minimoimisessa ja turvallisuuden parantamisessa.

Tässä työssä esitellään kaksi menetelmää paloriskien analysoimiseksi ydinvoimaloissa: Loviisan ydinvoimalan riskitutkimuksen menetelmä sekä U.S.
NRC:n kehittämä NUREG/CR-6850 menetelmä.
Loviisan ydinvoimalan suolanpoistolaitoksen paloriskejä analysoidaan näitä menetelmiä käyttäen.
Tärkeimmät tulokset ovat suolanpoistolaitokseen liittyvä palotaajuus sekä siitä aiheutuva paloriski.
Paloriskin koostumus esitetään kummallekin menetelmälle.

Menetelmiä arvioidaan niiden antamien tulosten sekä niiden käyttämiseen tarvittavan työmäärän suhteen.
Tämän arvioinnin perusteella annetaan suosituksia kummankin menetelmän käytöstä Loviisan ydinvoimalan paloriskien analysoinnista tulevaisuudessa.

Kummankin menetelmän huomattiin antavan samansuuntaisia tuloksia palotaajuuksille.
Tämä johtuu luultavasti menetelmissä käytettävien approksimaatioiden perusteeltaan samankaltaisista luonteista.

Menetelmien antamat paloriskit olivat myös samansuuntaisia.
Eräs menetelmien merkittävimmistä eroista oli, että NUREG/CR-6850:ssa esitetään menettely, jolla voidaan arvioida kaapelipalojen yhteydessä muodostuvien virheellisten automaatiosignaaleiden tapahtumistodennäköisyyksiä.
ED:2010-03-16
INSSI record number: 39113