search query: @supervisor Lampinen, Markku / total: 148
reference: 16 / 148
Author: | Nuora, Harri |
Title: | Massavirtasäätö - suljettujen putkiverkostojen tehonsäätö pumpun pyörimisnopeutta muuttamalla |
Massavirtasäätö - power control of closed piping system by changing pump's speed of rotation | |
Publication type: | Master's thesis |
Publication year: | 2011 |
Pages: | (9) + 102 s. + liitt. 27 Language: fin |
Department/School: | Energiatekniikan laitos |
Main subject: | Lämpötekniikka ja koneoppi (Ene-39) |
Supervisor: | Lampinen, Markku |
Instructor: | Toivonen, Jorma |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark Aalto 4890 | Archive |
Keywords: | pump district heat cooling temperature pumppu kaukolämpö jäähtymän tehostaminen |
Abstract (eng): | The competitiveness of district heat can be improved with better cooling temperature in the consumer devices. Both district heat consumer and seller profit from better cooling temperature in the system. The target of the study is a new secondary side coupling with witch better cooling can be gained than with the usual couplings. Coupling is called massavirtasäätö (mass flow adjustment) and its function is based on changing the pumps speed of rotation which causes alternation to heating power. Control valves and mixing connections are not used in this coupling. The target of this study is to make sure that the coupling works under any circumstances and verify with modelling and measuring how the coupling influence on cooling temperature. The effects of the components sizing and how the mass flow changes affected to the sizing were also studied. Modelling was made in stationary state for ventilation heating pipe and radiator network. Based on modelling the gained annual district heat return temperature duration curve was established. Ventilation heating pipe network flow balance in variable load circumstance was studied with numeric flow analysis method. Whole process characteristic curve was established with combining the heating of air conditioning unit process pumps and fin-tube heat exchangers characteristic curves. The results of the study prove that with the new coupling in supply air device heating systems a notably better cooling temperature can be gained annually than with the traditional coupling. Pumping costs also reduce radically. In the future mass flow adjustment could be also adapted to district heating's primary connections. Significant savings would be gained with the mass flow adjustment on the primary side of the district heating. |
Abstract (fin): | Kaukolämmön kilpailukykyä voidaan parantaa tehostamalla jäähtymää kuluttajalaitteissa. Jäähtymän tehostamisesta hyötyvät sekä kaukolämmön kuluttaja että lämmönmyyjä. Tutkimuksen kohteena on uusi toisiopuolen kytkentä, jolla saavutetaan perinteisiä kytkentöjä huomattavasti parempi jäähtymä. Kytkentä on nimetty massavirtasäädöksi ja sen toiminta perustuu siihen, että lämmityspiirien tehoa säädetään pumpun pyörimisnopeutta muuttamalla. Kytkennässä ei käytetä perinteisiä syöttöventtiileitä eikä sekoituskytkentöjä. Tutkimuksen tavoitteena oli varmistua kytkennän toiminnasta kaikissa olosuhteissa ja todeta mallinnuksin ja mittauksin kytkennän vaikutus jäähtymään. Lisäksi tutkittiin kytkennän komponenttien mitoittamista ja massavirran muutoksien vaikutusta niihin. Mallinnukset tehtiin stationääritilassa IV-lämpöjohto- ja patteriverkostoille. Mallinnusten perusteella laadittiin kytkennällä saavutettava vuotuinen kaukolämmön paluulämpötilan pysyvyyskäyrä. IV-lämpöjohtoverkostojen virtaustasapainoa muuttuvissa kuormitusolosuhteissa tutkittiin numeerisella virtausanalyysi menetelmällä. Ilmastoinnin lämmityksen yksikköprosessille laadittiin pumpun ja lamellipatterin ominaiskäyrien muodostama koko prosessin ominaiskäyrä. Tutkimustulokset osoittavat, että tuloilmakoneiden lämmityspiirissä uudella kytkennällä saavutetaan vuositasolla huomattavasti suurempi jäähtymä kuin perinteisellä kytkennällä. Paremman jäähtymän lisäksi pumppauskustannukset pienenevät radikaalisti. Tulevaisuudessa massavirtasäätöä voidaan soveltaa myös kaukolämmön ensiöpuolelle. Ensiöpuolella massavirtasäädöllä saavutettaisiin merkittäviä säästöjä. |
ED: | 2011-07-06 |
INSSI record number: 42636
+ add basket
INSSI