Author:Jokinen, Liisa
Title:Toimistorakennuksen maalämpö- ja maakylmäjärjestelmien suunnittelu
Designing geothermal and geo-cooling systems for office building
Publication type:Master's thesis
Publication year:2013
Pages:63 s. + liitt.      Language:   fin
Department/School:Energiatekniikan laitos
Main subject:LVI-tekniikka   (Ene-58)
Supervisor:Sirén, Kai
Instructor:Torkki, Antti
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  4601   | Archive
Keywords:geothermal heating
geothermal cooling
simulation
circuit diagram
maalämpö
maakylmä
simulointi
mallikytkentä
Abstract (eng): Designing renewable energy source is problematic from the designer's point of view.
There are no easily available, clear and comprehensive design manuals for designers to use.
When designer cannot dimension systems they do not necessarily use new systems in their designs.

The aim of this research was to produce designer's manual for designing geothermal heating and cooling systems for office building.
The study investigated the existing design guidance, rules of thumb, and a variety of models.
The study examined different design criteria's impact on geothermal field using the model object Strand.
Geothermal field's operation was studied with simulation program EED.
When designing geothermal and cooling system, the most challenging task to study large geothermal fields' effect on ground.

The parameters used in simulation were restriction of output, distance between boreholes and depth of boreholes.
Different results were compared to the model object's existing solution.
Based on the simulation results one of the situations were optimized and examined and compared to the original system's results.

Four different kinds of model circuit diagrams were produced for engineering office's use.
Various supplementary energy sources were shown in model circuit diagrams for geothermal heating.
Two different kinds of model circuit diagrams for geothermal cooling were shown.
The other one is based on passive cooling and the other one for active cooling.
Water-cooling unit is used for active cooling.

The study shows Finnish laws and regulations that effect on geothermal heating and cooling installation and designing.
Abstract (fin): Tutkimuksessa ongelmana oli uusiutuvien energialähteiden tuotannon suunnittelu kohteisiin.
Uusiutuvien energialähteiden suunnittelulle ei ole olemassa helposti saatavia, tarpeeksi selkeitä ja kattavia suunnitteluohjeita, joihin suunnittelija voisi tarvittaessa tukeutua.
Kun suunnittelija ei pysty mitoittamaan järjestelmää, ei välttämättä aloiteta käyttämään uusia järjestelmiä.

Tutkimuksen tavoitteena oli tuottaa suunnittelijoille ohjeet maalämpö- ja maakylmäjärjestelmien suunnittelusta toimistorakennuksessa.
Tutkimuksessa tutkittiin olemassa olevia mitoitusohjeita, nyrkkisääntöjä ja erilaisia malleja.
Tutkimuksessa tutkittiin mallikohteen avulla erilaisten mitoitusperusteiden vaikutuksia maalämpö- ja maakylmäkentän toimintaan.
Maalämpö- ja maakylmäkentän toimintaa tarkasteltiin simulointiohjelmalla EED.
Maalämpö- ja maakylmäjärjestelmien suunnittelussa oli haasteellisinta tutkia ison maalämpö- ja maakylmäkentän vaikutuksia maaperään.

Simuloinnissa muuttujina käytettiin tehorajoitusta, kaivojen valista etäisyyttä ja syvyyttä.
Erilaisia tuloksia verrattiin mallikohteen toteutettuun ratkaisuun.
Tehtyjen simulointien perusteella mitoitettiin optimoitu tilanne ja tutkittiin sen vaikutuksia lopputulokseen.

Työssä tuotettiin neljä erilaista mallikytkentää suunnittelutoimiston käyttöön.
Mallikytkennöissä on esitetty erilaisia lisäenergianlähteitä.
Lisäksi on esitetty maakylmälle sekä passiivisen järjestelmän, että aktiivisen järjestelmän kytkentä.
Aktiivisessa järjestelmässä on käytetty vedenjäähdytyskonetta.

Tutkimukseen on koottu maalämpö- ja maakylmäjärjestelmien asennukseen ja suunnitteluun vaikuttavat Suomen lait ja asetukset.
ED:2013-10-23