search query: @keyword aivosähkökäyrä / total: 16
reference: 10 / 16
« previous | next »
Author:Kallioniemi, Elisa
Title:Electroencephalography responses evoked by transcranial magnetic stimulation on the primary visual cortex
Primääriselle näköaivokuorelle kohdistetun transkraniaalisen magneettistimulaation aiheuttamat vasteet aivosähkökäyrässä
Publication type:Master's thesis
Publication year:2012
Pages:viii + 51 s. + liitt. 22      Language:   eng
Department/School:Elektroniikan laitos
Main subject:Sovellettu elektroniikka   (S-66)
Supervisor:Sepponen, Raimo
Instructor:Silvanto, Juha
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201210313335
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  838   | Archive
Keywords:transcranial magnetic stimulation
TMS
electroencephalography
EEG
evoked potential
visual cortex
phosphene
transkraniaalinen magneettistimulaatio
TMS
aivosähkökäyrä
EEG
herätepotentiaali
näköaivokuori
fosfiini
Abstract (eng): By combining transcranial magnetic stimulation (TMS) and electroencephalography (EEG) cortical excitability and connectivity can be studied non-invasively.
However, the method is still at an early stage as TMS causes large muscle artefacts to the EEG that are difficult to remove with the existing signal processing methods.

In this master's thesis the combination of simultaneous TMS and EEG (TMSEEG) was applied to the primary visual cortex.
The aim was to use independent component analysis (ICA) to clean the data from artefacts and to explore the neural EEG responses and artificial visual percepts, phosphenes, evoked by the stimulation.

The thesis covered a TMS-EEG and a TMS study, which both had five different paired-pulse protocols, a single pulse protocol, and a control protocol.
This was the first time ICA was applied to the primary visual cortex EEG, as well as the first time the human primary visual cortex neural responses to paired-pulse TMS were studied.

It was found that ICA removed the TMS-evoked artefacts from the primary visual cortex EEG.
In addition, the responses to the paired-pulse stimulation showed no significant differences when compared with the single pulse protocol.
Only the spatial spreading of the responses differed significantly.
However, the data analysis revealed several problems in the experimental design that need to be fixed before reliable conclusions can be drawn.
Abstract (fin): Yhdistämällä transkraniaalinen magneettistimulaatio (TMS) ja aivosähkökäyrä (EEG) voidaan aivokuoren reaktiivisuutta ja konnektivisuutta tutkia ei-invasiivisesti.
Menetelmä on vielä melko vähän sovellettu, sillä TMS aiheuttaa EEG:hen suuria artefaktoja, joita on vaikea poistaa nykyisillä signaalinkäsittelymenetelmillä.

Tässä diplomityössä EEG:n mittaus ja primäärisen näköaivokuoren TMS-stimulointi (TMS-EEG) suoritettiin samanaikaisesti.
Tavoitteena oli käyttää riippumattomien komponenttien analyysiä (ICA) artefaktojen poistoon ja tarkastella stimulaation aiheuttamia EEG-vasteita ja keinotekoisia näköhavaintoja eli fosfiineja.
Diplomityö käsitti TMS-EEG- ja TMS-mittaukset, joissa molemmissa käytettiin viittä eri paripulssi-, yhtä yksittäispulssi- sekä yhtä kontrolliprotokollaa.
Työssä ICA:ta sovellettiin primääriseltä näköaivokuorelta mitattuun EEG:hen ja tutkittiin paripulssiprotokollien aiheuttamia primäärisen näköaivokuoren vasteita ihmisillä ensimmäistä kertaa.

Työssä havaittiin, että ICA soveltui artefaktojen poistoon primäärisen näköaivokuoren EEG:stä.
Lisäksi paripulssiprotokollien aiheuttamista vasteista ei löydetty eroavaisuuksia verrattaessa niitä yksittäispulssiprotokollan vasteisiin.
Vain vasteiden spatiaalinen leviäminen erosi merkittävästi.
Data-analyysi paljasti kuitenkin mittausasetelmassa lukuisia ongelmia, jotka tulisi korjata ennen kuin luotettavia johtopäätöksiä voidaan tehdä.
ED:2012-10-08
INSSI record number: 45345
+ add basket
« previous | next »
INSSI