search query: @keyword quality / total: 170
reference: 101 / 170
Author: | Eskola, Lari |
Title: | Ilmanvaihtojärjestelmän puhtauden varmistaminen |
Verifying the cleanliness of the ventilation system | |
Publication type: | Master's thesis |
Publication year: | 2003 |
Pages: | 88 s. liitt. Language: fin |
Department/School: | Konetekniikan osasto |
Main subject: | LVI-tekniikka (Ene-58) |
Supervisor: | Seppänen, Olli |
Instructor: | Björkroth, Marko |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark TKK 6042 | Archive |
Keywords: | ventilation system cleanliness visual evaluation method quality ilmanvaihtojärjestelmä puhtaus visuaalinen menetelmä laatu |
Abstract (eng): | This thesis concerns the cleanliness of new ventilation systems. During the study a new inspection guideline for the cleanliness of ventilation systems was developed in the HVAC laboratory at Helsinki University of Technology. The field research investigated the cleanliness of newly installed ventilation systems in four buildings. The cost effectiveness of the installation was assessed. The work begins with a description of the concept of quality. The inspection guideline for clean ventilation systems consists of instructions, a visual evaluation method and inspection lists. The visual evaluation method was developed to be used during the inspection of the cleanliness of new ventilation systems. The visual evaluation method was created by comparing dust samples, taken with the vacuum test method, with photographs that were taken from the same ducts. The cleanliness scale presents a series of photographs with the corresponding dust level in g/m2. In the field research, the level of cleanliness and the installation methods of the new ventilation systems were inspected. Ducts were well protected against dust at two building sites. The unprotected ducts at the other two building sites had to be cleaned thoroughly. Only few sections of the protected ducts needed to be cleaned to attain the cleanliness level Pl. The capping of the ducts was done successfully in one of the buildings. If the capping was done carelessly or the cap was broken or removed too early the ducts got dusty. The capping of the ducts resulted in the most cost effective installation in one building and the most expensive installation in another. The cleaning costs were 0.4-6.7% of the total installation costs. After cleaning, all the systems attained the PI level. Building sizes were not taken into account in the cost analyses. The visual evaluation method for cleanliness control is a fast inspection method. It is advisable to be used during the whole construction project. There is a need to develop better capping methods for protecting ventilation systems against contamination. |
Abstract (fin): | Diplomityössä on käsitelty uusien ilmanvaihtojärjestelmien toteutuksen ongelmia puhtauden suhteen. Työn aikana kehitettiin ilmanvaihtojärjestelmän puhtauden tarkastusohje Teknillisen korkeakoulun LVI-tekniikan laboratoriossa. Kenttätutkimuksessa selvitettiin neljän koekohteen ilmanvaihtojärjestelmien puhtautta ja arvioitiin käytettyjen asennusmenetelmien kannattavuutta. Lisäksi työn alkuun on koottu yhteenveto laatuun liittyvistä käsitteistä. Ilmanvaihtojärjestelmän puhtauden tarkastusmenetelmä koostuu tarkastusohjeesta, visuaalisesta arviointimenetelmästä sekä tarkastuslistoista. Visuaalinen puhtaudenarviointimenetelmä on tarkoitettu uusien ilmanvaihtojärjestelmien puhtauden tarkastamiseen. Visuaalinen arviointimenetelmä luotiin vertaamalla suodatinkeräysmenetelmällä otettuja polykertymänäytteitä ja kanavista otettuja valokuvia. Muodostettiin asteikko, jossa polykertymäarvoa vastaa asteikossa oleva valokuva. Neljässä koekohteessa on tehty kenttäolosuhteissa selvitys puhtauden tasosta ja käytetyistä asennusmenetelmistä. Koekohteissa käytettiin sekä suojaamista että suojaamatta jättämistä. Suojaamattomien kohteiden kanavat jouduttiin puhdistamaan kokonaan, suojattujen vain paikallisesti, P1-luokan puhtauden tason saavuttamiseksi. Suojaaminen onnistui erittäin hyvin yhdessä kohteessa. Huolimattomasti tehty suojaus tai suojauksen rikkoontuminen sekä liian aikaisin poistettu suojaus johtivat kanavien likaantumiseen. Neljästä kohteesta sekä halvin että kallein asennuskustannus kanavametriä kohden sisälsi kanavien suojaamisen. Kohteiden puhdistuskustannukset olivat 0,4-6,7 % kokonaiskustannuksista. Puhdistamien jälkeen kaikki kohteet saavuttivat P1-luokan. Kohteiden suuruuseroja ei huomioitu kustannusten vertailussa. Visuaalinen menetelmä on nopea puhtaudentarkastusmenetelmä ja sitä tulee soveltaa koko rakennusprojektin ajan. Ilmanvaihtojärjestelmien suojausmenetelmien kehittäminen havaittiin tarpeelliseksi. |
ED: | 2004-01-19 |
INSSI record number: 21111
+ add basket
INSSI