search query: @keyword millimeter waves / total: 18
reference: 2 / 18
« previous | next »
Author:Dahlberg, Krista
Title:Mixer test jig for millimeter wave Schottky diodes
Testialusta millimetriaaltoalueen Schottky-diodeille
Publication type:Licentiate thesis
Publication year:2010
Pages:89 s. + liitt. 8      Language:   eng
Department/School:Radiotieteen ja -tekniikan laitos
Main subject:Radiotekniikka   (S-26)
Supervisor:Räisänen, Antti
Instructor:Mallat, Juha ; Louhi, Jyrki
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  590   | Archive
Keywords:Schottky diode
mixer test jig
millimeter waves
conversion loss
noise temperature
Schottky-diodi
testialusta
millimetriaallot
sekoitusvaimennus
kohinalämpötila
Abstract (eng): In this Licentiate's thesis, a mixer test jig for millimetre wave Schottky diodes has been designed, fabricated, and tested.
With the mixer test jig different Schottky diodes can be tested and compared in the actual operating environment at the nominal design frequency of 183 GHz.
The diode under test is mounted on a substrate and radio frequency (RF) and local oscillator (LO) impedance matching is performed with an integrated low-loss EH-tuner.
The structure is simple, and the substrate with the diode can be easily changed.

The performance of the mixer test jig is tested with a commercial Schottky diode (VDISC2T6).
Single sideband (SSB) conversion loss measurement and noise measurement based determination of double sideband (DSB) conversion loss and mixer DSB noise o temperature are carried out.
The measured SSB conversion loss at the signal frequency of. 183 GHz is 7.8 dB and at the image frequency of 181.04 GHz it is 8.5 dB with 2.3 mW LO power at 182.02 GHz.
The measured SSB conversion loss at the signal frequency is 6.8 dB, when at the intermediate frequency the matching is optimized with an impedance tuner.

In the noise-based measurements a diplexer is needed for LO source noise filtering.
The measured DSB conversion loss is 4.9 dB and the mixer DSB noise temperature is 780 K with 2.1 mW LO power at 182.6 GHz with the intermediate frequency of 1.05 GHz.
The measured SSB conversion losses are comparable to the best published results of fundamental mixers at 183 GHz.
The noise measurement results are slightly worse because the instability of the LO source and the need of noise filtering.
Abstract (fin): Tässä lisensiaatintutkimuksessa on suunniteltu, valmistettu ja testattu testialusta millimetriaaltoalueen Schottky-diodeille.
Testialustalla erilaisia Schottky-diodeja voidaan testata ja vertailla niiden varsinaisessa toimintaympäristössä nimellisellä 183 GHz:n suunnittelutaajuudella.
Testattava diodi kiinnitetään substraatille Ja radiotaajuuden ja paikallisoskillaattoritaajuuden impedanssit sovitetaan integroidulla vähähäviöisellä EH-virittimellä.
Testialustan rakenne on yksinkertainen, ja substraatti diodeineen voidaan vaihtaa helposti.

Testialustan toiminta on testattu kaupallisella Schottky-diodilla (VDI-SC2T6).
Yksisivukaistainen (SSB) sekoitusvaimennusmittaus sekä kohinamittauksiin perustuva kaksisivukaistainen (DSB) sekoitusvaimennus ja sekoittimen kohinalämpötila on määritetty.
Mitattu SSB-sekoitusvaimennus 183 GHz:n signaalitaajuudella on 7,8 dB ja 181,04 GHz:n peilitaajuudella se on 8,5 dB, kun paikallisoskillaattoriteho on 2,3 mW 182,02 GHz:n taajuudella.
Mitattu SSB-sekoitusvaimennus signaalitaajuudella on 6,8 dB, kun välitaajuudella sovitus on optimoitu impedanssivirittimellä.

Kohinaan perustuvissa mittauksissa tarvitaan diplekseri poistamaan LO-lähteen kohinaa.
Paras mitattu DSB-sekoitusvaimennus on 4,9 dB ja DSB-kohinalämpötila on 780 K käyttäessä 2,1 mW:n LO-tehoa 182,6 GHz:n taajuudella ja välitaajuuden ollessa 1,05 GHz.
Mitatut SSB-sekoitusvaimennukset ovat verrattavissa parhaisiin julkaistuihin tuloksiin yksidiodiselle sekoittimelle 183 GHz:lla.
Kohinamittaustulokset ovat hieman huonompia johtuen LO-lähteen epästabiilisuudesta ja tarvittavasta LO-lähteen kohinan suodatuksesta.
ED:2011-05-03
INSSI record number: 41609
+ add basket
« previous | next »
INSSI