Author:Kuutti, Jussi
Title:Kalibrointikaasujen sekoitusmenetelmien tutkiminen ja kehittäminen
Research and Development of mixing calibration gases
Publication type:Master's thesis
Publication year:2009
Pages:106      Language:   fin
Department/School:Elektroniikan, tietoliikenteen ja automaation tiedekunta
Degree programme:Elektroniikan ja sähkötekniikan tutkinto-ohjelma
Main subject:Sovellettu elektroniikka   (S-66)
Supervisor:Sepponen, Raimo
Instructor:Pitkäkoski, Antero ; Kotamäki, Ilkka
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201203071293
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark S80     | Archive
Keywords:carbon dioxide flow
nitrogen flow
gas mixing
mass flow
volumetric flow
mass flow meter and controller
mass flow calibration
hiilidioksidivirtaus
typpivirtaus
kaasujen sekoitus
massavirtaus
tilavuusvirtaus
massavirtamittari ja -säädin
massavirtakalibrointi
Abstract (eng): The aim of this thesis was to find a suitable method to produce traceable carbon dioxide - nitrogen mixtures for 0,01...2 % carbon dioxide concentration.
The new method was supposed to be more accurate than the existing one.
An additional aim was to consider the suitability of the method to produce different gas mixtures as well, e.g. oxygen - nitrogen mixtures.
On the basis of the accomplished market analysis the research was focused on a mixing system involving mass flow controllers.

For the tests thermal and differential pressure based mass flow controllers were ordered, both types from different manufacturers.
Series of test calibrations, similar to those used for present thermal controllers were then carried out.
The performances of the controllers were compared by correction to the mass flow reading, repeatability and hysteresis of the measurement.
To find out possible pressure dependence of mass flow readings additional calibrations were carried out to nitrogen controllers, with two different supply pressures.
The controller type in use was excluded.

On the basis of the calibration results, the mass flow controller type currently in use was not the best of the controllers included in the tests.
At the lowest carbon dioxide concentration reachable (0,07 %) with the calibration ranges the standard uncertainty of the mass flow reading was with the best test controller type 0,19 % for the CO2 controller, and 0,01 % for the N2 controller.
The standard uncertainty oftargeted 0,01 % C02 concentration could not be estimated due to limitations of the calibration ranges.
Abstract (fin): Työn tavoitteena oli löytää sopiva menetelmä tuottaa jäljitettävästi ja käytössä olevaa sekoitustapaa tarkemmin hiilidioksidi-typpikaasuseoksia, 0,01...2 % hiilidioksidipitoisuudella.
Lisäksi tavoitteena oli arvioida valitun menetelmän soveltuvuus muiden kaasuseosten, esimerkkinä happi-typpiseos, valmistamiseen.
Tehdyn markkinatutkimuksen perusteella keskityttiin massavirtasäätimillä toteutettavan sekoitusjärjestelmän tutkimiseen.

Testejä varten tilattiin termisiä sekä differentiaalipaineen mittaukseen perustuvia hiilidioksidi- ja typpimassavirtasäätimiä.
Säädintyypit olivat eri laitevalmistajilta.
Näille sekä nykyisin käytössä oleville termisille massavirtasäätimille tehtiin sarja koekalibrointeja.
Säätimien suorituskykyä vertailtiin massavirtalukeman korjauksen sekä mittauksen toistuvuuden ja hystereesin perusteella.
Käytössä olevia säätimiä lukuun ottamatta, typpisäätimille tehtiin lisäkalibroinnit kahdella eri syöttöpaineella, mahdollisen massavirtalukeman paineriippuvuuden selvittämiseksi.

Koekalibrointitulosten perusteella nykyisin käytössä olevat massavirtasäätimet eivät pärjänneet testin parhaalle säädinmallille.
Massavirtalukemien suhteellinen standardiepävarmuus kalibrointialueilla saavutettavalla pienimmällä 0,07 % hiilidioksidipitoisuudella oli testien parhaan säädinmallin CO2- säätimelle 0,19 %, ja N2-säätimelle 0,01 %.
Tavoitteeksi asetetun 0,01 % C02-pitoisuuden suhteellista standardiepävarmuutta ei kalibrointialueiden rajoitusten vuoksi voitu arvioida.