Author:Keto, Matias
Title:Energiamuotojen kertoimet rakennusten energiatehokkuuden määrittämiseksi
Energy efficiency indicators of power and heat generation in Finland
Publication type:Master's thesis
Publication year:2010
Pages:92 s. + liitt. 13      Language:   fin
Department/School:Energiatekniikan laitos
Main subject:LVI-tekniikka   (Ene-58)
Supervisor:Sirén, Kai
Instructor:Kurnitski, Jarek
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  4602   | Archive
Keywords:energy efficiency indicators
primary energy factor
specific emissions
combined heat and power
energy method
benefit allocation method
primäärienergiakerroin
ominaispäästökerroin
yhteistuotanto
energiamenetelmä
hyödynjakomenetelmä
Abstract (eng): Energy efficiency indicators of energy production, such as specific emissions and primary energy factors, provide means to evaluate energy efficiency of buildings in terms of environmental impact and consumption of natural resources.
In this thesis, primary energy factors and specific carbon dioxide emissions of electricity and district heat production in Finland are studied in detail, focusing especially on the different methods to allocate fuel energy and emissions between co-generated power and heat (i.e. combined power and heat (CHP)).

Applying the benefit allocation method to split the fuel energy and emissions between cogenerated power and heat, the average specific emissions of electricity and district heating in Finland between 2000 - 2007 are found to be 274 g(CO2)/kWh and 217 g(CO2)/kWh, respectively.
The corresponding range of variations is 204 - 351 g (CO2)/kWh and 203 - 226 g (CO2)/kWh.
Based on the same allocation method, the average primary energy factor is found to be 0.90 for district heating and 2.22 for electricity, and corresponding range of variations 0.89 - 0.91 and 2.15 - 2.31, respectively.
The primary energy factors presented above are total primary energy factors, where primary energy efficiency of nuclear electricity is set to 33 % and hydropower to 100 %.
Results show that while the primary energy factors of both electricity and district heating, as well as the specific emissions of district heating, remain approximately constant, the range of variation of the specific emissions of electricity is wide.
The values of the indicators depend on the allocation method and primary energy conventions.
One should therefore be careful not to compare values based on different allocation methods and conventions.
Abstract (fin): Rakennusten energiatehokkuutta voidaan arvioida rakennuksen kuluttamaan energiaan tai energian kulutuksen seurauksiin perustuen.
Energian kulutuksen seuraukset ovat verrannollisia kulutettuun energiamäärään.
Energiamuotojen kerroin on kulutetun energian ja kulutuksen seurauksien välinen verrannollisuuskerroin.
Tässä diplomityössä kulutuksen seurauksia käsitellään sähkön- ja lämmöntuotannon hiilidioksidipäästöihin ja primäärienergian kulutukseen perustuen.
Työn painopiste on sähkön ja lämmön yhteistuotantoa sisältävän tuotantorakenteen käsittelyssä.
Työssä johdetaan sähkön- ja lämmöntuotannon hyötysuhteista, yhteistuotannon rakennusasteesta ja sähkön ja lämmön tuotantomuotojen osuuksista riippuvat yleispätevät yhtälöt sähkön- ja lämmöntuotannon ominaispäästöille (päästökertoimille) sekä primäärienergian ominaiskulutukselle (primäärienergiakertoimille), sekä tarkastellaan toteutuneen tuotannon ominaispäästöjä ja primäärienergiakertoimia vuosina 2000 - 2007.
Yhtälöiden johtamisen tarkoituksena on tarkastella ominaispäästöihin ja primäärienergiakertoimiin vaikuttavia tekijöitä.

Toteutuneesta tuotannosta ja johdetuista yhtälöistä nähdään, että kaukolämmön kertoimien taso on pysynyt vuositasolla vakaana, ja tulee todennäköisesti pysymään myös jatkossa, sillä muutokset kertoimiin vaikuttavissa tekijöissä ovat pieniä eikä kerroin riipu voimakkaasti tekijöiden muutoksista.
Suomessa tuotetun kaukolämmön kokonaistuotannon päästö- ja primäärienergia kertoimien keskiarvot vuosilta 2000 - 2007 ovat, sähkö ja lämmön yhteistuotannon päästöt ja polttoaineet hyödynjakomenetelmällä jakaen, 217 g(CO2)/kWh ja 0,90.
Kertoimien vaihteluväli on 203 - 226 g(CO2)/kWh ja 0,89 - 0,91.

Sähköntuotannon toteutuneista kertoimista ja johdetuista yhtälöistä nähdään, että sähkön- tuotannon primäärienergiakertoimen taso on säilynyt, ja säilynee myös tulevaisuudessa, vuositasolla vakaana, mutta päästökertoimen vuosittaiset vaihtelut ovat suuria.
Suomessa tuotetun sähkön kokonaisprimäärienergiakertoimen keskiarvo vuosilta 2000 - 2007 on 2,22 ja päästökertoimen 274 g(CO2)/kWh.
Vastaavat vaihteluvälit ovat päästökertoimelle 204 - 351 g(CO2)/kWh ja primäärienergiakertoimelle 2,15 - 2,31.
Yhteistuotannon polttoaineet on kertoimia laskettaessa jaettu hyödynjakomenetelmällä.
Kokonaisprimäärienergiakerroin sisältää sekä uusiutumattomat että uusituvat energianlähteet.
Ydinvoimalle on kertoimia laskettaessa käytetty primäärienergiakerrointa 3,03, vesi- ja tulivoimalle kerrointa 1,00 ja polttoaineiden primäärienergiana on käytetty aiempaa lämpöarvoa.