search query: @instructor Vdovenko, Konstantin / total: 2
reference: 1 / 2
« previous | next »
Author:Vanninen, Joonas
Title:Digital Communications Between Medical Imaging Modalities and Information Systems
Publication type:Master's thesis
Publication year:2010
Pages:77      Language:   eng
Department/School:Informaatio- ja luonnontieteiden tiedekunta
Main subject:Lääketieteellinen tekniikka   (Tfy-99)
Supervisor:Ilmoniemi, Risto
Instructor:Vdovenko, Konstantin ; Myllylä, Markku
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  43   | Archive
Keywords:DICOM
IHE
medical imaging
virtual modality
medical IT integration
DICOM
IHE
lääketieteellinen kuvantaminen
virtuaalinen modaliteetti
lääketieteellisen tietotekniikan integraatio
Abstract (eng): This work studies the digital communication methods between medical imaging modalities and information systems.
DICOM is the essential standard used for this purpose.
In the last decade, additional specifications have been provided by the IHE organization of how to use the standard in the integration of the whole medical imaging department.

In this work, the DICOM interfaces for a medical imaging information system are designed and implemented.
Also, a virtual modality software is designed and implemented to allow non-DICOM modalities to be used in the imaging workflow.

The IHE specifications were considered to be useful in defining the requirements of the software, but also the local requirements have to be taken into account.
The software was designed using service-oriented architecture.
The DCM4CHE2 programming library was found to be an adequate basis for the implementation.

The resulted software has been thoroughly tested for instance in the IHE Connectathon testing event.
They have also been deployed in production use with several systems.
Abstract (fin): Tämän työn tarkoituksena on tutkia digitaalisia tiedonsiirtomenetelmiä lääketieteellisten kuvantamislaitteiden ja tietojärjestelmien välillä.
DICOM on keskeisin tähän tarkoitukseen käytettävä standardi.
Viime vuosikymmenen aikana kansainvälinen IHE-organisaatio on kehittänyt tarkentavia määrityksiä sille, kuinka standardeja tulisi käyttää koko kuvantamisosaston integraatiossa.

Työssä määritellään, suunnitellaan ja toteutetaan DICOM-rajapinnat lääketieteellisen kuvantamisen työnohjausjärjestelmään sekä virtuaalimodaliteetti-ohjelma, joka mahdollistaa ei-DICOM-modaliteettien käytön kuvantamisen työnkulussa.

IHE-määrittelyt havaittiin hyödyllisiksi vaatimusten määrittelyssä, mutta myös paikalliset vaatimukset on syytä ottaa huomioon.
Ohjelmistot suunniteltiin palvelupohjaisen arkkitehtuurin mukaisesti.
DICOM-toteutuksen pohjana käytettiin DCM4CHE2 -kirjastoa, joka osoittautui hyödylliseksi työkaluksi ohjelmistokehityksessä.

Tulokseksi saatuja ohjelmistoja testattiin perusteellisesti muun muassa IHE Connectahon -testitapahtumassa.
Ne on myös otettu tuotantokäyttöön usean järjestelmän yhteydessä.
ED:2010-11-19
INSSI record number: 41338
+ add basket
« previous | next »
INSSI