search query: @instructor Aula, Ari / total: 2
reference: 1 / 2
« previous | next »
Author:Aarnio, Aleksi
Title:Design of an environmental simulation room
Olosuhdehuoneen suunnittelu
Publication type:Master's thesis
Publication year:2013
Pages:75 s. + liitt. 9      Language:   eng
Department/School:Koneenrakennustekniikan laitos
Main subject:Koneensuunnitteluoppi   (Kon-41)
Supervisor:Kuosmanen, Petri
Instructor:Aula, Ari
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  4822   | Archive
Keywords:air conditioner
close control unit
environmental simulation
performance testing
humidity control
temperature control
ilmastointilaite
vakioilmastointikone
ympäristösimulointi
suorituskyvyn mittaaminen
kosteudenhallinta
lämpötilan hallinta
Abstract (eng): The goal of this thesis is to design an environmental simulation room for close control unit product development tests.
The temperature and the humidity in the room must be controlled and the effect of the test unit on the environmental conditions must be cancelled.

The affecting requirements are identified and listed.
After that they are classified based on their effect on the individual room components.
The challenges are cancelling the high internal loads, achieving low temperature differences and maintaining the desired high humidities.
These will be done by the air reconditioning partition of the room.
The different components of the room that are chosen are the building envelope, the heat exchanger, fans, humidifying and dehumidifying system, internal floor and internal ceiling.

As a result the layout, dimensions and the individual components of the room are determined.
The requirements can be fulfilled by high air flow rates, by distributing the air flow evenly into the room and by avoiding the condense of water in the air reconditioning partition.
The whole building envelope is insulated.
Air reconditioning partition consists of two 6-row 1500 x 2100 mm air/liquid heat exchangers.
Air is circulated by backward curved centrifugal fans.
It enters the room through a raised floor that covers the entire area of the room.
Air returns into the reconditioning partition at the level of the ceiling.
The open area of the floor is adjustable between 0 and 36 % to provide even air flow everywhere in the room.

The sensors of the data acquisition system and some of the results that they could provide are briefly discussed.
The environmental conditions that can be, maintained during a test are illustrated in Mollier diagram.
The designed room can be used for testing close control units in controlled conditions.
Abstract (fin): Tämän työn tavoite on suunnitella olosuhdehuone vakioilmastointikoneiden tuotekehitystestejä varten.
Huoneen lämpötilan ja kosteuden on oltava säädettävissä ja testattava laite ei saa muuttaa olosuhteita kohtuuttomasti.

Suunnitteluun vaikuttavat vaatimukset on tunnistettu ja listattu.
Tämän jälkeen ne on ryhmitelty perustuen siihen mihin huoneen komponenteista ne vaikuttavat.
Suurimmat haasteet ovat huoneen sisäisten lämpö- ja kosteuskuormien tasaaminen, matalien lämpötilaerojen saavuttaminen ja suuren ilmankosteuden ylläpitäminen.
Huoneen ilmankäsittelylaitteisto huolehtii kaikista näistä.
Työssä valitaan huoneeseen soveltuvat yksittäiset komponentit joita ovat eristemateriaali, lämmönvaihdin, puhallin, kuivatus- ja kostutuslaitteisto sekä sisäinen katto- ja lattiarakenne.

Työn tuloksena on päätetty huoneen mitat, siihen soveltuvimmat komponentit ja niiden sijoittelu.
Aiemmin mainitut vaatimukset voidaan täyttää suurilla ilman virtaamilla, jakamalla ilmavirta tasaisesti kaikkialle huoneeseen ja välttämällä kosteuden kondensoituminen huoneen ilmankäsittelylaitteistossa.
Huone on rakennettu eriste-elementeistä.
Ilmankäsittelylaitteistossa käytetään kahta kuusirivistä 1500 x 2100 mm lämmönvaihdinta.
Ilmaa kierrätetään radiaalipuhaltimilla.
Ilmavirta ohjataan huoneeseen korotetun lattian lävitse ja se palaa ilmankäsittelylaitteistoon katon tasalta.
Avoin lattia-ala on säädettävissä välillä 0-36 % jotta ilmavirta voidaan jakaa tasaisesti kaikkialle huoneeseen.

Tiedonkeruujärjestelmän antureita ja niillä saatavia tuloksia käsitellään lyhyesti.
Huoneessa ylläpidettävät olosuhteet on esitetty Mollier-diagrammissa.
Suunniteltu huone mahdollistaa vakioilmastointikoneiden testaamisen hallituissa olosuhteissa.
ED:2013-10-14
INSSI record number: 47302
+ add basket
« previous | next »
INSSI