search query: @author Keski-Rahkonen, Olli / total: 2
reference: 1 / 2
« previous | next »
Author:Keski-Rahkonen, Olli
Title:Safe Torque Off Concept for Inverters
Safe torque off -konsepti inverttereille
Publication type:Master's thesis
Publication year:2014
Pages:viii + 80 s. + liitt. 2      Language:   eng
Department/School:Sähkötekniikan korkeakoulu
Main subject:Elektroniikan integrointi ja luotettavuus   (S3007)
Supervisor:Paulasto-Kröckel, Mervi
Instructor:Kangas, Ilpo
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201405131800
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  1040   | Archive
Keywords:emergency stop
safe torque off
reliability
IEC 61508
FMEDA
hätäpysäytystoiminto
luotettavuus
Abstract (eng):The purpose of this work is to develop a concept for safe torque off function that is used to ensure the safe state of an inverter emergency stop.
The work concentrates on alternating current motor inverters.
The theoretical background presented includes the basic knowledge of reliability engineering, functional safety, frequency converters and field-programmable gate arrays (FPGA).
The work has been commissioned by the department of High Power Drives of ABB Oy.

A major target of this work is to design a safe torque off concept that can be implemented into both two and three-level inverter topologies and their parallel connections.
Six different safe torque off concepts are presented and compared by the analytic hierarchy process (AHP).
Concepts' reliability and functional safety capabilities are assessed with failure modes, effects and diagnostics analysis (FMEDA).

Finally, a safe torque off concept fulfilling the requirements with safety integrity level SIL 3 and performance level PL e capability is presented.
Within the requirements given, the best results were obtained with those concepts that were implemented using field-programmable gate arrays in the safe torque off logic circuit.
Abstract (fin):Työn tarkoituksena on kehittää safe torque off€ -konsept, jota käytetään vaihtovirta-moottorikäytön invertterin hätäpysäytyksen turvallisen tilan varmistamiseen.
Työn teoreettinen osuus sisältää perusteet luotettavuustekniikasta, toiminnallisesta turvallisuudesta, taajuusmuuttajista ja ohjelmoitavista porttimatriisipiireistä (FPGA).
Tämä työ on tehty ABB Oy:n High Power Drives -tulosyksikön toimeksiannosta.

Työn ensisijaisena tavoittena on suunnitella safe torque off konsepti, jota voidaan soveltaa sekä kaksi- ja kolmitasoinverttereille että niiden rinnankytkennöille.
Työssä esitellään kuusi erilaista konseptia, joiden paremmuusjärjestys määrätään analyyttisella hierarkiaprosessilla (AHP).
Lisäksi konseptien luotettavuutta ja toiminnallisen turvallisuuden tasoa arvioidaan käyttäen vian ja sen vaikutuksen diagnostiikan analyysiä (FMEDA).

Tuloksena esitellään safe torque off -konsepti, joka täyttää työssä asetetut tavoitteet toiminnallisen turvallisuuden eheystason SIL 3 ja suoritustason PL e.
Vaatimukset parhaiten täyttäviksi konsepteiksi todettiin ne, joissa osa safe torque off -toiminnon logiikasta on toteutettu porttimatriisipiireillä.