search query: @keyword OPC / total: 20
reference: 11 / 20
« previous | next »
Author:Orrainen, Antti
Title:Communications design for relay elevators and escalators in a distributed monitoring and control system
Releohjattujen hissien ja liukuportaiden tiedonsiirto hajautetussa valvontajärjestelmässä
Publication type:Master's thesis
Publication year:2004
Pages:xi + 109 s. + liitt. 15      Language:   eng
Department/School:Sähkö- ja tietoliikennetekniikan osasto
Main subject:Tietoliikennetekniikka   (S-72)
Supervisor:Korhonen, Timo
Instructor:Suihkonen, Kari
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark S80     | Archive
Keywords:monitoring and control systems for elevators and escalators
field buses
relay elevators and escalators
distributed I/O
OPC
LonWorks technology
hissien ja liukuportaiden valvontajärjestelmät
kenttäväylät
releohjatut hissit ja liukuportaat
hajautettu I/O
LongWorks-tekniikka
Abstract (eng): Elevators and escalators are important elements of modern buildings.
Furthermore, monitoring and control systems for elevators and escalators are closely related to other building automation systems.
Consequently, making these monitoring and control systems interoperable with other building automation are an ongoing challenge in the elevator and escalator business.

This thesis discusses a distributed monitoring and control system for elevators and escalators which is being developed by KONE Corporation.
The system relies on the open OPC (Object Linking and Embedding for Process Control) standard to provide interoperability with other automation systems.
The purpose of this thesis is to present a design for how relay elevators and escalators can be connected to this new system via a field bus which is based on the LonWorks technology.
That is, the field bus level communications of the system are addressed.

The thesis starts by presenting the OPC and LonWorks technologies.
The actual communications design for relay elevators and escalators considers the structure of the field bus, the data flow transmitted via it and a network driver that is able to interface with the OPC level of the system.
In addition, the suitability of the LonWorks technology for transmitting real-time data is evaluated with the help of simulations.
It is concluded that the LonWorks technology is able to suit the application in question if limitations (the maximum number of nodes, the allowable transmission rate) to the utilisation of the field bus are set.

All in all, the thesis presents an example of how proprietary field bus systems can be made open with the help of the OPC standard.
It also points out design issues that must be taken into account when designing systems with the LonWorks technology.
Abstract (fin): Hissit ja liukuportaat ovat olennainen osa modernia rakennusta.
Valvontajärjestelmät, joilla hissejä ja liukuportaita voidaan monitoroida ja ohjata etänä, ovat osa taloautomaatiota.
Näiden valvontajärjestelmien tekeminen yhteensopivaksi muun taloautomaation kanssa onkin haaste hissi- ja liukuporrasalalle.

Tämä diplomityö käsittelee KONE Oyj:ssä valmisteilla olevaa hajautettua hissien ja liukuportaiden valvontajärjestelmää, joka tarjoaa OPC (Object Linking and Embedding for Process Control) -standardin mukaisen avoimen rajapinnan.
Tämä rajapinta mahdollistaa valvontajärjestelmän liittämisen osaksi muuta taloautomaatiota.
Diplomityön tavoitteena on esittää suunnitelma siitä, miten releohjatut hissit ja liukuportaat voidaan LonWorks-pohjaista kenttäväylää hyväksi käyttäen kytkeä tähän uuteen valvontajärjestelmään.

OPC-standardin ja LonWorks-tekniikan perusteiden lisäksi työssä esitetään tiedonsiirtosuunnitelma, jossa käsitellään kenttäväylän rakennetta, itse tiedonsiirtoa sekä verkkoajuria, jolla kenttäväylä voidaan liittää osaksi Opec-mallin mukaista järjestelmää.
Lisäksi arvioidaan simulaatioiden avulla sitä, miten hyvin LonWorks -tekniikka soveltuu reaaliaikaisen tiedon siirtämiseen.
Työssä todetaan, että LonWorks -pohjainen kenttäväylä soveltuu tietyin rajoituksin (laitteiden määrä väylässä, lähetystahti) kyseessä olevan valvontajärjestelmän tarpeisiin.

Diplomityössä tarkasteltu järjestelmä on yksi esimerkki siitä, miten suljettu kenttäväylä voidaan liittää osaksi avointa OPC-systeemiä.
Lisäksi työssä tuodaan esille seikkoja, jotka tulee ottaa huomioon suunniteltaessa LonWorks-tekniikkaan perustuvaa kenttäväylää.
ED:2004-09-01
INSSI record number: 26217
+ add basket
« previous | next »
INSSI