search query: @supervisor Haarla, Liisa / total: 21
reference: 5 / 21
Author: | Helistö, Niina |
Title: | Suomen kantaverkon mallintaminen tehonjakolaskentaa varten |
Modelling the Finnish Transmission Grid for Power Flow Studies | |
Publication type: | Master's thesis |
Publication year: | 2012 |
Pages: | [11] + 82 Language: fin |
Department/School: | Sähkötekniikan laitos |
Main subject: | Sähköverkot ja suurjännitetekniikka (S-18) |
Supervisor: | Haarla, Liisa |
Instructor: | Uski-Joutsenvuo, Sanna |
Electronic version URL: | http://urn.fi/URN:NBN:fi:aalto-201209213151 |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark Aalto 788 | Archive |
Keywords: | transmission grid grid model power flow load flow sähkönsiirtoverkko verkkomalli tehonjako |
Abstract (eng): | Power system is formed by power grid, generators at power plants and consumers' loads. Power system analysis requires different types of simulation models describing power markets and power grids. At power transmission grid level, the most widely used network calculation form is power flow analysis. It is used to determine the power flows in the grid in a symmetric, steady-state situation. The aim of this thesis was to build a simulation model of the Finnish transmission grid for power flow studies. Information on power grid components were collected from public sources, such as power engineering textbooks and handbooks, old theses as well as the websites of energy sector companies and organizations. The grid data were entered into a database that was build side by side with this thesis. The data can be fetched from the database to a simulation model, which is fed to a power system simulation software. The simulation model was validated by comparing the simulation results obtained by it to the public results obtained by the grid model of the Finnish national grid company. The conclusion was that the grid model developed in this thesis describes Finnish transmission grid with moderate accuracy when studying active power flows in 400 kV and 220 kV grids. The grid model will bring a significant improvement in research that requires a description of the Finnish transmission grid and in which simulation models of the Finnish national grid company are not available. However, the grid model as such is not suitable for accurate reactive power studies or 110 kV network analysis. |
Abstract (fin): | Sähköverkko, voimalaitosten generaattorit ja kuluttajien kuormat muodostavat sähköjärjestelmän. Sähköjärjestelmän tarkastelussa tarvitaan erilaisia sähkömarkkinoita ja sähköverkkoja kuvaavia simulointimalleja. Kantaverkon tarkastelussa eniten käytetty verkostolaskennan muoto on tehonjakolaskenta. Tehonjakolaskennan avulla selvitetään sähköverkon tehonsiirrot pysyvässä, symmetrisessätilanteessa. Tämän diplomityön tavoitteena oli rakentaa tehonjakolaskentaan soveltuva simulointimalli Suomen kantaverkosta. Tietoja kantaverkon rakenneosista kerättiin julkisista lähteistä, kuten sähkövoimatekniikan oppi- ja käsikirjoista, vanhoista diplomitöistä sekäenergia-alan yhtiöiden ja järjestöjen Internet-sivuilta. Kerätyt tiedot koottiin tämän diplomityön yhteydessä rakennettuun verkkotietokantaan, josta tiedot voidaan hakea sopivassa muodossa simulointimalliin, joka syötetään verkostolaskentaohjelmistoon. Simulointimalli validoitiin vertaamalla sillä saatuja simulaatiotuloksia Suomen kantaverkkoyhtiön simulointimallilla saatuihin julkisiin tuloksiin. Validoinnin johtopäätöksenä todettiin, että diplomityössä rakennettu verkkomalli kuvaa Suomen kantaverkkoa suuntaa antavasti, kun tarkastellaan pätötehonsiirtoja 400 kV:n ja 220 kV:n verkoissa. Verkkomalli tuo merkittävän parannuksen tutkimukseen, jossa tarvitaan kuvausta Suomen kantaverkosta ja jossa ei ole käytettävissäSuomen kantaverkkoyhtiön simulointimalleja. Kovin tarkkaan loistehotarkasteluun tai 110 kV:n verkkojen tarkasteluun verkkomallia ei kuitenkaan nykyisellään voi käyttää. |
ED: | 2012-06-19 |
INSSI record number: 44683
+ add basket