search query: @keyword magnetic resonance imaging / total: 22
reference: 5 / 22
Author: | Vesanen, Panu |
Title: | Compressed sensing in parallel magnetic resonance imaging |
Pakattu mittaus rinnakkaismagneettikuvauksessa | |
Publication type: | Master's thesis |
Publication year: | 2009 |
Pages: | vi + 54 Language: eng |
Department/School: | Lääketieteellisen tekniikan ja laskennallisen tieteen laitos |
Main subject: | Lääketieteellinen tekniikka (Tfy-99) |
Supervisor: | Ilmoniemi, Risto |
Instructor: | |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark T80 | Archive |
Keywords: | magnetic resonance imaging MRI compressed sensing |
Abstract (eng): | Magnetic resonance imaging (MRI) is a non-invasive method that allows the study of interior structures of matter. MRI is based on magnetizing a sample, manipulating the magnetization, and detecting the magnetic field that the sample produces. Today, MRI is widely used in medical imaging. Reductions in the MRI measurement time are important because they correspond to, e.g. higher throughput of MRI scanners or enhanced spatial resolution of images. It is well-known that natural images, such as MR images, are compressible. Compressed sensing (CS) is a method that exploits the compressibility of signals in order to measure and reconstruct them efficiently. Moreover, in parallel MRI (pMRI), the magnetic fields produced by the magnetized sample are measured with multiple coils simultaneously. The differing sensitivity profiles of the coils allow a faster rate of information flow compared to single-coil receiving. In this work, CS and pMRI are combined to achieve shortened measurement times. Theory of CS, pMRI, and their combination are reviewed. Simulations were conducted to demonstrate the performance of the method in idealistic conditions. In addition, experimental measurements were performed to validate the technique in practice. Simulation results indicate that the combination of CS with pMRI reduces the measurement time by 30-50 %. Experimentally, reductions of 10-20 % were obtained. |
ED: | 2009-08-28 |
INSSI record number: 38185
+ add basket
INSSI