search query: @instructor Kajaste, Jyrki / total: 22
reference: 10 / 22
« previous | next »
Author:Saarikoski, Tuomas
Title:Hardware-in-the-Loop -simuloinnin soveltuvuus hydraulisen vaimentimen testaukseen
Suitability of Hardware-in-the-Loop -simulation in testing of hydraulic dampers
Publication type:Master's thesis
Publication year:2010
Pages:(6) + 77 s. + liitt. 3      Language:   fin
Department/School:Koneenrakennustekniikan laitos
Main subject:Koneensuunnitteluoppi   (Kon-41)
Supervisor:Pietola, Matti
Instructor:Kajaste, Jyrki
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  6051   | Archive
Keywords:HIL
hydraulic
damper
testing
hydraulinen
vaimennin
testaus
Abstract (eng): This research studies the suitability of real-time Hardware-in-the-Loop -simulation in testing of hydraulic dampers.
With HiL-simulation the aim is to create a virtual, realistic operational environment for the damper under test.
The system includes a plant model and a real-time interface to embed the damper as part of the simulation.

The literature part of the study discusses the requirements of real-time HiL-simulation and results from earlier studies.
Feasibility and possible limitations of the method in damper testing were investigated with the use of computer simulations and an experimental HiL-set-up.
The goal was to construct a virtual plant model and to establish a working interface between the plant and damper under test.
The real-time plant model was created using Simulink and xPC-Target software.
Motion described by the plant model was produced using a hydraulic actuator and the damping force generated was measured using a load sensor.
Measured damping force was then fed back to the plant model.

HiL-simulation was found to be a functional method for testing damper hardware.
Testing done with the HiL-set-up produced consistent results with good repeatability.
The actuator was able to produce the motion of the plant model with good accuracy, giving a realistic damping force in the system.
It should be noted though, that without a point of comparison the definitive accuracy of the results is hard to determine.

The most substantial limitation of the system was found out to be the caused by actuator dynamics in the real-time simulation.
With fast movements the actuator was unable to produce required movement or caused significant phase lag.
With further development in improving actuator dynamics HiL-method holds a lot of potential and the included plant model also makes it suitable for testing semi-active and active dampers.
Abstract (fin): Tässä työssä on tutkittu reaaliaikaisen Hardware-in-the-Loop (HiL) -simuloinnin soveltuvuutta vaimennintestaukseen.
HiL-simuloinnissa testattavalle vaimentimelle pyritään luomaan virtuaalinen, todellisen kaltainen toimintaympäristö.
Järjestelmä sisältää mallin vaimennettavasta prosessista ja reaaliaikaisen rajapinnan, jonka avulla vaimennin sulautetaan osaksi simulointia.

Työn kirjallisuusosassa käsitellään reaaliaikaisen HiL-simuloinnin yleisiä vaatimuksia ja aikaisemmista tutkimuksista saatuja tuloksia.
HiL-menetelmän toimivuutta ja mahdollisia rajoitteita vaimennintestauksessa tutkittiin tietokonesimulaatioiden ja Hydraulitekniikan laboratorioon rakennetun koelaitteiston avulla.
Tavoitteena oli kehittää järjestelmään virtuaalinen prosessimalli ja luoda toimiva reaaliaikainen rajapinta prosessimallin ja testattavan vaimentimen välille.
Reaaliaikainen prosessimalli toteutettiin Simulink ja xPC Target -ohjelmistoilla.
Prosessimallin liike tuotettiin asemaohjatulla hydraulisella toimilaitteella ja vaimentimen tuottamaa vaimennusvoimaa mitattiin voima-anturilla.
Mitattu vaimennusvoima syötettiin takaisin prosessisimulaatioon.

HiL-simuloinnin todettiin olevan toimiva konsepti vaimennintestauksessa.
Koelaitteistolla saadut mittaustulokset olivat johdonmukaisia ja niiden toistettavuus oli hyvä.
Toimilaite kykeni tuottamaan prosessimallin liikkeen vaimentimelle hyvällä tarkkuudella, jolloin vaimenninvoimajärjestelmässä on realistinen.
Saatujen mittaustulosten tarkkuuden arviointia vaikeuttaa kuitenkin vertailukohteen puuttuminen.

Järjestelmän merkittävimmäksi pullonkaulaksi osoittautui toimilaitteen tuoma dynamiikka reaaliaikaiseen simulaatioon.
Suuremmilla nopeuksilla toimilaite ei pystynyt tuottamaan vaadittua liikettä tai vaihesiirto kasvoi liian suureksi.
Parantamalla toimilaitteen dynamiikkaa menetelmässä on paljon potentiaalia, sillä mukana olevan prosessimallin ansiosta se soveltuu myös puoliaktiivisten ja aktiivisten vaimentimien testaukseen.
ED:2010-10-28
INSSI record number: 41240
+ add basket
« previous | next »
INSSI