Author:Heikkinen, Timo-Pekka
Title:Testing the Performance of a Commercial Active Network Measurement Platform
Publication type:Master's thesis
Publication year:2008
Pages:xii + 80      Language:   eng
Department/School:Tietoliikenne- ja tietoverkkotekniikan laitos
Main subject:Tietoverkkotekniikka   (S-38)
Supervisor:Kantola, Raimo
Instructor:Luoma, Marko
Electronic version URL: http://urn.fi/urn:nbn:fi:tkk-011887
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  7212   | Archive
Keywords:active measurement
network
packet loss
delay
available bandwidth
Brix
verifiers
aktiivimittaukset
tietoverkko
pakettihukka
viive
vapaa kaistanleveys
Brix Verifier
Abstract (eng):In this thesis, a commercial active network measurement platform is tested for performance and accuracy.
The platform is also tested for ability to detect certain events in networks.
Two types of measurement probes are tested: the low performance Brix 100 Verifier and the high performance Brix 1000 Verifier.
It is found that both platform's measurement probe types are accurate when measuring round-trip delay, but do not perform nearly as well when measuring one-way delay.
External synchronization, such as GPS, helps the Brix 1000 Verifier to reach sub-millisecond measurement accuracy.
As Brix 100 Verifiers do not support external synchronization, their accuracy is suitable only for measuring one-way delays larger than a few milliseconds.

The platform is able to detect sudden high load levels and router failures in a network, but fails to detect short (sub-second) link breaks.

In the theory part of this thesis, some well known active measurement methods and mechanisms are presented.
Also, challenges related to active measurement are discussed and some of the recent major academic active measurement projects are introduced.
Abstract (fin):Diplomityössä testataan ja mitataan yhden kaupallisen aktiivimittausalustan suorituskyky ja tarkkuus.
Myös alustan kyky havaita tiettyjä tapahtumia tietoverkoissa testataan.
Testeissä on mukana kaksi erityyppistä alustaan kuuluvaa mittalaitetta: alhaisen suorituskyvyn Brix 100 Verifier ja tehokkaampi Brix 1000 Verifier.
Testauksen tuloksena voidaan sanoa, että molemmat mittalaitetyypit soveltuvat hyvin kiertoaikaviiveen mittaamiseen.
Yhdensuuntaisen viiveen mittaukseen Brix 100 ei sovellu etenkään mitattaessa alhaisia viivetasoja (∼1ms).
Ulkoista synkronisointilähdettä, kuten GPS-kelloa, käytettäessä Brix 1000 -mittalaitetta voidaan käyttää myös yhdensuuntaisen viiveen mittaamiseen.

Mittausalusta havaitsee verkossa tapahtuvat kuormitustilanteet ja reititinviat, mutta se ei kykene havaitsemaan lyhyitä alle sekunnin mittaisia katkoja.