Author:Rajakaski, Aleksi
Title:Electricity market models as an analysis tool for a transmission system operator - A comparative assessment within Nordic experience
Sähkömarkkinamallit kantaverkkoyhtiön analyysityökaluna pohjoismaisessa kontekstissa
Publication type:Master's thesis
Publication year:2010
Pages:92 [+20]      Language:   eng
Department/School:Energiatekniikan laitos
Main subject:Energiatalous ja voimalaitostekniikka   (Ene-59)
Supervisor:Lahdelma, Risto
Instructor:Sulamaa, Pekka ; Matilainen, Jussi
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  5979   | Archive
Keywords:electricity market models
hydrothermal power system
BID
EMPS
WILMAR
SDDP
sähkömarkkinamallit
vesivoima
lämpövoima
BID
EMPS
SDDP
WILMAR
Abstract (eng): This study assesses a suitable market analysis tool for a Nordic transmission system operator (TSO).
The focus is on the electricity markets in the Baltic Sea region characterized by the significant share of hydropower, in the Nordic countries, the large degree of electricity market deregulation, and the multi-country day-ahead electricity trading via Nord Pool power exchange.

Several market modelling approaches area analyzed for the market analysis purposes of a TSO.
Market models applying a bottom-up approach are found to be the most suitable due to their ability to simulate the interactions between the market players while satisfying detailed technological constraints.
Four electricity market models applying bottom-up description of the markets are analyzed including EMPS, BID, SDDP, and WILMAR.
The main features of these models are summarized and the suitability of these models is assessed for the purposes of a TSO operating in the Baltic Sea region.

Features of EMPS and SDDP models are found to be fairly similar and thus they are concluded equally suitable for the market analysis purposes of a TSO operating in the Baltic Sea region.
The BID model is considered suitable as well.
The main differences between these three models relate to the accuracy of the market simulation and to the level of detail applied for representing hydropower, thermal power, and transmission grid.
The modelling of hydropower applied in WILMAR is considered inaccurate for analyzing the electricity markets in the Baltic Sea region.

Both the qualitative aspects and the quantitative properties of the BID model are compared against those of the EMPS model, the de facto electricity market model among the Nordic market players.
The comparison indicates that BID is more user-friendly than EMPS and that the hourly time resolution, applied in the BID model, contributes to the market behaviour when simulating an electricity market with intermittent generation.
However, the hydropower modelling is considered more realistic in the EMPS model.

Finally, a market analysis is executed using the BID model.
The analysis measures the effects of a grid investment on the electricity markets of the Baltic Sea region.
The analysis further reinforces the arguments for the BID model as a comprehensive analysis tool for a TSO to supplement the EMPS model.
The BID model is considered especially suitable for analyzing electricity markets dominated by thermal generation.
Abstract (fin): Työssä vertaillaan Itämeren alueen sähkömarkkinoitten analysointiin soveltuvia työkaluja kantaverkkoyhtiön näkökulmasta.
Itämerta ympäröivän alueen sähkömarkkinoitten ominaispiirteiksi voidaan luetella vesivoimavaltaisuus pohjoismaiden osalta, avoimuus kilpailulle sekä Nord Pool-sähköpörssin mahdollistama usean maan kattava sähkökauppa.

Neljää eri markkinamallinnusmenetelmää analysoidaan.
Bottom-up-menetelmä todetaan parhaiten soveltuvaksi kantaverkkoyhtiön tarpeisiin, johtuen menetelmän kyvystä kuvata markkinoiden toimintaa yksityiskohtaiset huomioiden sekä tekniset että markkinoiden asettamat rajoitusehdot.
Työssä analysoidaan neljää eri sähkömarkkinamallia, jotka kaikki soveltavat bottom-up-menetelmää.
Nämä mallit ovat EMPS, BID, SDDP ja WILMAR.

Sekä EMPS- että SDDP-mallien ominaisuudet todetaan hyvin samankaltaisiksi ja soveltuviksi kantaverkkoyhtiölle Itämeren alueen sähkömarkkinoitten analysointiin.
Mallien vahvuutena on vesivoiman yksityiskohtainen mallinnus.
Analyysin perusteella myös BID-malli todetaan soveltuvaksi kantaverkkoyhtiön analyysityökaluksi, sen vahvuutena on markkinoiden simulointi tuntiresoluutiolla.
WILMARin epätarkan vesivoimamallinnuksen vuoksi malli ei sovellu Itämeren alueen sähkömarkkinoiden analysointiin.

BID-mallin käytettävyyttä sekä laskennallisia ominaisuuksia analysoidaan tarkemmin vertaamalla sitä pohjoismaisilla sähkömarkkinoilla yleisesti käytössä olevaan EMPS-malliin.
Analyysi osoittaa, että BID-mallin käytettävyys on merkittävästi EMPS-mallia parempi.
Lisäksi tuntiresoluution tuoma etu tulee selvästi esiin simuloitaessa markkina-aluetta, jossa on vaihtelevaa tuotantokapasiteettia.
Vertailu osoittaa, että EMPS-mallin vesivoimatuotannon mallinnus on realistisempi verrattuna BID-mallissa käytettävään menetelmään.

Lopuksi BID-mallilla analysoidaan kantaverkkoinvestoinnin vaikutuksia Itämeren alueen sähkömarkkinoihin.
Analyysi vahvistaa käsitystä BID-mallin soveltuvuudesta kantaverkkoyhtiön analyysityökaluksi tukemaan nykyisin käytössä olevaa EMPS-mallia.
Erityisesti BID-malli soveltuu lämpövoimavaltaisten sähkömarkkinoiden analysointiin.