search query: @supervisor Kauppinen, Esko / total: 28
reference: 11 / 28
« previous | next »
Author:Suomi, Visa
Title:3-D Motion-Tracking for High-Intensity Focused Ultrasound Therapy
Publication type:Master's thesis
Publication year:2012
Pages:[9] + 52      Language:   eng
Department/School:Teknillisen fysiikan laitos
Main subject:Fysiikka   (Tfy-3)
Supervisor:Kauppinen, Esko
Instructor:Tillander, Matti
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201509164285
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  117   | Archive
Keywords:HIFU
focused ultrasoud
therapy
motion-tracking
HIFU
fokusoitu ultraääni
terapia
liikkeenseuranta
Abstract (eng): Respiratory motion during high-intensity focused ultrasound (HIFU) therapy reduces the efficiency of the treatment in abdominal organs.
Hence, for the purpose of motion-correction during HIFU therapy, two different ultrasound-based 3-D motion-tracking methods were presented and adapted to the existing Philips Sonalleve MR-HIFU platform.
The displacement estimation accuracies of these two techniques were determined using a metal pin and an in vitro tissue sample as targets.
The measurement data was collected on all movement directions using element clusters consisting of one, three and 32 transmitting transducer elements.
Simulations of the acoustic fields were also performed in order to discuss the theoretical limitations of the motion-tracking with the existing HIFU system.

The displacement estimation accuracies did not differ significantly for the two different techniques introduced but was rather dependent on the transmitting element cluster size and the orientation of the ultrasound beam axis.
Using smaller number of elements and defining the beam axis angle accurately in the calculation algorithm yielded more stable results.
The motion-tracking using the in vitro tissue sample was significantly more difficult to achieve than with the metal pin target.
This was due to the incorrect time-shift values given by the cross-correlation algorithm.
Hence, the failed channels had to be manually excluded from the calculations in order to yield the correct displacement estimation values.

The introduced motion-tracking methods cannot be readily used as such during clinical HIFU therapy treatment, because the incorrect time-shift values had to be manually excluded from the calculation algorithm.
This process could probably be automated by observing the peak count and the amplitude of the cross-correlation curves.
However, this method was not verified in this thesis and hence requires further research about its feasibility.
Abstract (fin): Korkeaintensiteettisen fokusoidun ultraääniterapian (HIFU) aikana tapahtuva hengitys vähentää hoidon lämmitystehoa vatsa-alueen elimissä, mikä voidaan kompensoida reaaliaikaisella 3-D -liikkeenkorjauksella.
Siksi tässä työssä esitettiin kaksi eri liikkeenseurantamenetelmää, jotka voidaan integroida sellaisenaan Philips Sonalleve MR-HIFU -terapia-alustaan.
Näiden menetelmien tarkkuudet mitattiin käyttämällä seurattavina kohteina metallista neulaa sekä kudosnäytettä, joiden avulla mittausdata kerättiin kaikilta liikesuunnilta hyödyntäen yhtä, kolmea ja 32:ta lähettävää ultraäänielementtiä.
Lisäksi näiden elementtijoukkojen akustiset kentät simuloitiin, jotta voitiin selvittää esiteltyjen liikkeenseurantamenetelmien teoreettiset rajoitukset käytetyllä HIFU-alustalla.

Liikkeenseurantatarkkuudet eivät eronneet merkittävästi kahden esitetyn menetelmän välillä, vaan tarkkuus oli ennemminkin riippuvainen käytetyn elementtijoukon koosta sekä ultraäänikeilan suunnasta.
Pienemmän elementtijoukon käyttäminen ja ultraäänikeilan asennon oikea määrittäminen paransivat saatujen mittaustulosten toistettavuutta.
Liikkeenseuranta käyttäen kohteena kudosnäytettä oli huomattavasti vaikeampaa kuin metallineulan seuraaminen, mikä johtui ristikorrelaatioalgoritmin antamista vääristä aika-arvoista.
Tämän takia ne piti manuaalisesti poistaa laskennasta oikean tuloksen saamiseksi.

Esitettyjä liikkeenseurantamenetelmiä ei voida sellaisenaan hyödyntää kliinisessä HIFU-terapiassa, koska väärät aika-arvot piti manuaalisesti poistaa laskenta-algoritmista.
Tämä prosessi olisi mahdollisesti voitu automatisoida seuraamalla ristikorrelaatiokäyrien huippumääriä ja amplitudeja.
Kyseistä menetelmää ei kuitenkaan verifioitu tässä työssä, minkä takia vaadittaisiin lisätutkimuksia sen toteuttamiskelpoisuudesta.
ED:2012-09-24
INSSI record number: 45294
+ add basket
« previous | next »
INSSI