search query: @keyword loiva katto / total: 3
reference: 1 / 3
« previous | next »
Author:Hovi, Viljami
Title:Loivien kermieristettyjen kattojen kosteuskäyttäytyminen eri rakenneratkaisuissa
Hydrobehaviour of low slope membrane sheeted roofs in different structural solutions
Publication type:Master's thesis
Publication year:2009
Pages:59 s. + liitt. 13 s.      Language:   fin
Department/School:Rakenne- ja rakennustuotantotekniikan laitos
Main subject:Talonrakennustekniikka   (Rak-43)
Supervisor:Puttonen, Jari
Instructor:Leivo, Eero
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto     | Archive
Keywords:membrane
humidity
follow-up measuring
low slope roof
kermi
kosteus
seurantamittaus
loiva katto
Abstract (eng): Building a ventilated low slope roof is expensive and has an effect on several working phases.
If the water vapour transmission rate was high enough, there would be no use for ventilation.
The target of this research is to clarify the amount and the gradient of humidity in building structures as well as possible benefits of the ventilation.

A low slope roof has an inclination of 1:10 or less.
It consists of a load-bearing structure, a humidity barrier, an insulation layer, a water-proofing component and potentially a covering for the water proofing.
Three different buildings in Southern Finland were considered in this research.
All three buildings were completed in the second quarter of the year 2009.
The roofs were made in November 2008, which is the time when the measuring started.

The applied measuring devices were temperature and humidity sensors including data loggers.
Altogether, 12 sensors were installed; four group of three sensors in each three building.
The first sensor was installed on the humidity barrier, the second in the middle of the insulation layer and the third 30 mm below the water proofing.
In addition, one sensor measuring the outside conditions and another sensor measuring the inside conditions were installed through the smoke outlet.
The measured data were logged in intervals of 30 minutes.

The results show that the rate of humidity in structure is rather high because it is constantly higher than the rate of outside humidity.
This is due to a large amount of moisture pervading the insulation material during the construction of the roof.
No abnormal amount of moisture was observed in the roof structures, for example, as it might result from water leakages.

This research shows that humidity can cause damage to the building structures before they dry out.
One of the main results is that drying is a slow process and therefore insulation material should be as dry as possible during construction.
Abstract (fin): Suurien hallirakennusten kattorakenteiden tuuletuksen tekeminen on kallista ja vaikuttaa useimpiin työvaiheisiin katon rakentamisen aikana.
Mikäli kattokermin vesihöyrynläpäisevyys olisi riittävä, tuuletuksen tekemisestä aiheutuvat kustannukset voitaisiin välttää.
Tämän tutkimuksen päätavoitteena oli selvittää PVC-katteellisen loivan kattorakenteen kosteuskäyttäytymistä.
Lisäksi pyrittiin selvittämään uritetulla eristyksellä toteutetun tuuletuksen vaikutuksia rakenteen toimintaan.

Loivina kattoina pidetään kattoja, joiden kaltevuus on 1:10 tai vähemmän.
Yläpohjarakenne kostuu kuormia siirtävästä rakenteesta, ilman- tai höyrynsulusta, lämmöneristekerroksista sekä vedeneristyksestä ja mahdollisesta vedeneristyksen suojakerroksesta.
Tutkimuskohteiksi valittiin kolme käyttötarkoitukseltaan erityyppistä hallirakennusta, joista yksi sijaitsee Turun lähellä Liedossa ja kaksi muuta Tuusulassa.
Kaikki kolme kohdetta valmistuivat vuoden 2009 toisella neljänneksellä ja kattoasennukset suoritettiin marraskuussa 2008.

Kohteissa mittaukset suoritettiin Pietiko Oy:n toimittamilla Hygrochron kosteus- ja lämpötila-antureilla (valmistaja Maxim lntegrate Products lnc.), joita asennettiin kuhunkin kohteeseen yhteensä 24 kappaletta.
Mittarit asennettiin neljään kolmen mittarin ryhmään siten, että kussakin ryhmässä mittarit olivat vastaavasti: alin höyrynsulun yläpuolella, seuraava eristekerroksen keskellä ja ylin noin 30 millimetriä vesieristeen alapuolella.
Lisäksi kohteisiin asennettiin yksi vastaava anturi ulkotilaan lähelle rakenteen pintaa, sekä yksi rakennuksen sisään savunpoistoluukun kohdalle, kattorakenteen alapinnan tasolle.
Mitattuja arvoja anturit tallensivat tutkimusjaksolla 30 minuutin välein.
Mittaustulosten perusteella voidaan todeta että rakenteessa on huomattavasti kosteutta sillä koko mittausjakson ajan suhteellisen kosteuden arvot pysyivät suurempina kuin ulkoilmassa vastaavana aikana.
Tämä johtuu suurehkosta rakennuskosteudesta.
Mittauksissa ei havaittu poikkeuksellisia kosteuslähteitä kuten sadevesivuotoja.

Tutkimus osoittaa, että rakenteen kuivuminen PVC-kermin läpi tapahtuu hyvin hitaasti.
Kuivuminen on niin hidasta, että mikäli eristeisiin pääsee rakennusvaiheessa kosteutta on mahdollista että rakenteeseen syntyy vaurioita ennen kosteuden poistumista.