search query: @instructor Peräsaari, Petri / total: 3
reference: 1 / 3
« previous | next »
Author:Keränen, Jari
Title:Käytettävyystekniikkaprosessin soveltaminen lääketieteellisten laitteiden valmistajalle
Application of Usability Engineering Process for a Medical Equipment Manufacturer
Publication type:Master's thesis
Publication year:2010
Pages:[14] + 91 s. + liitt. 16      Language:   fin
Department/School:Elektroniikan, tietoliikenteen ja automaation tiedekunta
Main subject:Laskennallinen tekniikka   (S-114)
Supervisor:Sams, Mikko
Instructor:Peräsaari, Petri
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201203131398
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  867   | Archive
Keywords:usability engineering process
usability
quality systems
medical equipment
IEC 62366:2007
IEC 60601-1:2005
käytettävyystekniikkaprosessi
käytettävyys
laatujärjestelmät
lääketieteelliset laitteet
IEC 62366:2007
IEC 60601-1:2005
Abstract (eng): The objective for the thesis was to define a Usability Engineering Process for a medical device manufacturer.
The defined Usability Engineering Process shall comply with the requirements set by the harmonized standard IEC 62366:2007 and shall be aligned with the existing product development process of the manufacturer.
Further, the Usability Engineering process shall provide conformity to the essential requirements set by European Council and European Parliament Directive 2007/47/EC.

In the literature study the principles of usability engineering are presented.
The roles and deliverables for the Usability Engineering Process are identified, and requirements engineering for defining proper usability requirements is discussed.
Also, methods for assessing compliance with the requirements are presented.
In the application study the current status of Usability Engineering is determined by conducting a survey among product development personnel and later reviewing the results with a capability model for usability engineering.
The artefact analysis method is used to identify the phases and roles of the current product development process.

An applied process of the Usability Engineering Process and the product development process was defined.
In addition, investment requirements for personnel and facilities were proposed, and two discount Usability Engineering methods were introduced: Heuristic Analysis and Simplified Thinking Aloud.

The results of this thesis can be generalised and applied to other medical device manufacturers with similar capabilities for Usability Engineering and product development processes.

The Usability Engineering Process was tested in theory by a documentation exercise with deliverables for a case project.
As a next step, the testing of the Usability Engineering Process in practise is proposed.
Later, a full scale implementation of the Usability Engineering Process is suggested.
Abstract (fin): Työn tavoitteena oli määritellä lääketieteellisiä laitteita valmistavalle yritykselle käytettävyystekniikkaprosessi, joka täyttää harmonisoidun standardin IEC 62366:2007 käytettävyystekniikkaprosessille asettamat vaatimukset ja Euroopan parlamentin ja neuvoston direktiivin 2007/47/EY olennaiset vaatimukset.
Työn lopullisena tavoitteena pidettiin yrityksen tuoteprosessiin saumattomasti yhdistyvää käytettävyystekniikkaprosessia.

Kirjallisuusosiossa määriteltiin, mitä on käytettävyystekniikka, millaisia vaatimuksia käytettävyydelle voidaan asettaa ja miten vaatimusten toteutumista voidaan arvioida.
Lisäksi tarkasteltiin, millaisia dokumentteja käytettävyystekniikkaprosessissa syntyy ja millaisia työntekijä- tai esimiesrooleja tarvitaan.

Työn sovellusosassa arvioitiin lääketieteellisiä laitteita valmistavan yrityksen lähtötila käytettävyystekniikan hyödyntämisessä.
Lisäksi selvitettiin, mitä vaiheita yrityksen tuoteprosessi ja tuotemuutosprosessi sisältävät ja millaisia rooleja tuotekehityksessä jo on.

Tulosten perusteella sovellettiin harmonisoidun standardin IEC 62366:2007 mukainen käytettävyystekniikkaprosessi osaksi yrityksen tuoteprosessia.
Lisäksi määriteltiin kehitysehdotuksia käytettävyystekniikkaan liittyvien fasiliteettien ja henkilöstön kompetenssien kehittämiseksi.
Menetelmiksi esitettiin kaksi yksinkertaista käytettävyystekniikkamenetelmää: heuristinen arviointi ja yksinkertaistettu ääneenpuhumismenetelmä.
Tulokset ovat yleistettävissä muihin lääketieteellisiä laitteita valmistaviin yrityksiin, mikäli yrityksen tuoteprosessi ja taso käytettävyystekniikan hyödyntämisessä vastaa tämän työn kohdeyritystä.

Yritykseen sovellettua käytettävyystekniikkaprosessia testattiin koeprojektiin olemassa olevan dokumentaation pohjalta teoriassa.
Seuraavana askeleena ehdotetaan käytettävyystekniikkaprosessin testausta käytännössä ja pidemmällä aikavälillä käytettävyystekniikkaprosessin käyttöönottoa koko kohdeyrityksen laajuudessa.