search query: @keyword quarry / total: 3
reference: 2 / 3
« previous | next »
Author:Lehtomäki, Antti
Title:Murskauslaitoksen, valmisbetonitehtaan ja betonituotetehtaan energiansäästömahdollisuudet
Energy saving opportunities in quarries, ready-mix and pre-cast concrete plants
Publication type:Master's thesis
Publication year:2011
Pages:69      Language:   fin
Department/School:Energiatekniikan laitos
Main subject:Energiatalous ja voimalaitostekniikka   (Ene-59)
Supervisor:Ahtila, Pekka
Instructor:Sivula, Kari ; Kiuru, Tomi
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  6809   | Archive
Keywords:quarry
ready-mix concrete
pre-cast concrete
crushing
energy efficiency
valmisbetoni
murskaus
betonituote
energiansäästö
energiatehokkuus
Abstract (eng): Increasing energy costs have raised the importance of energy efficiency in quarries and concrete production plants.
Energy audits found saving potential of 29 MWh (2%) in stationary quarry and 2 MWh (0%) in mobile crushing plant.
The average saving potential of four ready-mix concrete plants was 82 MWh (18%) in electricity and 100 MWh (15%) in heat, four pre-cast concrete plants had an average saving potential of 94 MWh (14%) in electricity and 257MWh (23%) in heat.

This thesis was done to find additional energy saving opportunities not included in the energy audits.
In addition to concrete methods to conserve energy, an energy efficiency monitoring program was planned.
The cost and benefit of moving from a monthly monitoring to day-level monitoring was established.
Crushers idle power consumption was calculated in stationary crushing plant, and possible solution to reduce it was planned.
The effect of IE3-and IE4-class electric motors was also calculated.
Also the energy consumed by crushers lubricant oils electric heaters while not in production was measured.

In the ready-mix side the feasibility of IE3-and IE4-electric motors was calculated.
The variables affecting compressed air system were studied and the possibility to use electric actuators was considered.
The option to use rainwater collection systems and solar panels was studied in pre-cast concrete factories.
Abstract (fin): Kohonneet energiakustannukset ovat nostaneet energiatehokkuuden ajankohtaiseksi murskauksessa ja betonintuotannossa.
Energiakatselmuksissa havaittiin kiinteän murskauslaitoksen vuotuiseksi sähkönsäästöpotentiaaliksi 29 MWh sähköä (2 %) ja Lokotrack-aseman 2 MWh (0 %), neljän valmisbetonitehtaan keskimääräiseksi säästöpotentiaaliksi saatiin 82 MWh sähkössä (18 %) ja 100 MWh (15 %) lämmössä, betonituotetehtaiden säästöpotentiaali on sähkössä 94 MWh (14 %) ja lämmössä 257 MWh (23 %).

Tässä työssä etsittiin säästökohteita jotka täydentäisivät energiakatselmuksissa havaittuja toimenpiteitä.
Toimenpiteiden lisäksi suunniteltiin energianseurantajärjestelmä, jolla voidaan siirtyä kuukausitason seurannasta päivätason seurantaan sekä arvioitiin päivätason seurannasta saatu hyöty ja kustannus.

Murskauslaitokselle laskettiin murskainten tyhjäkäyntiajan aiheuttama vuosittainen kustannus ja hahmoteltiin ratkaisuja sen vähentämiseen.
Tämän lisäksi laskettiin IE3-ja IE4-luokan sähkömoottoreiden tuoma säästö sekä arvioitiin hammastettujen kiilahihnojen kannattavuus.
Murskauslaitoksella mitattiin lisäksi voiteluöljyjen sähkövastusten käyttämä energia tuotannon ulkopuolella ja sen kustannus.

Valmisbetoniasemilla selvitettiin IE3-ja IE4-sähkömoottorien kannattavuus ja paineilmajärjestelmän kustannuksiin vaikuttavat tekijät.
Betonituotetehtaille arvioitiin sadevedenkeruujärjestelmän ja aurinkosähkön kannattavuus.