search query: @keyword fluid-structure interaction / total: 3
reference: 1 / 3
« previous | next »
Author: | Matilainen, Jussi |
Title: | Seismic analysis of a liquid-filled tower-type shell structure |
Nesteellä täytetyn reaktoritornin maanjäristystarkastelu | |
Publication type: | Master's thesis |
Publication year: | 2014 |
Pages: | 66 + 42 Language: eng |
Department/School: | Insinööritieteiden korkeakoulu |
Main subject: | Rakennetekniikka (R3001) |
Supervisor: | Puttonen, Jari |
Instructor: | Piironen, Jukka |
Electronic version URL: | http://urn.fi/URN:NBN:fi:aalto-201403251634 |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark Aalto | Archive |
Keywords: | EN 1998 earthquake ground motions seismic design finite element method arbitrary Lagrangian-Eulerian ALE Euler-Lagrange coupling fluid-structure interaction seisminen kuorma aikahistoriat elementtimenetelmä nesteen ja rakenteen vuorovaikutus FSI |
Abstract (eng): | The purpose of this study is to introduce a numerical technique for analyzing a liquid-filled shell structure under EN 1998 compliant earthquake ground motions. Prescriptions of the EN 1998 to the representation of earthquake ground motion as accelerograms are explained. Accelerograms representing the ground motion are generated by matching recorded accelerograms to a response spectrum and, alternatively, artificial accelerograms are generated for reference. For the numerical simulations, structures are treated with traditional Lagrangian formulation while the liquid is represented by arbitrary Lagrangian-Eulerian (ALE) formulation. Governing equations of the ALE formulation, the Mie-Grüneisen equation of state representing the fluid and a solving strategy based on operator splitting are introduced. Euler-Lagrange coupling algorithm is employed to achieve the fluid-structure interaction. Coupling mechanism based on a spring-damper system and its possible drawbacks are illustrated. The numerical method is verified with three examples based on previous research papers which demonstrate its reliability. An industrial-sized liquidfilled tower subjected to both the matched and artificial tri-axial accelerograms is analyzed. Horizontal deflections of both the liquid-filled and empty towers due to the matched and artificial accelerograms are determined. The liquid-fill is also taken into account by simply adding the liquid mass to the mass of the empty tower in order to evaluate how much the liquid motion affects the structural response. As a result of this study, information is gained from both the effect of ground motion selection process and liquid fill on the structural response of the tower. Vertical ground motion had no effect on the response because the tower as a vertical cantilever does not possess any modes of importance in the vertical direction. The use of artificial accelerograms resulted in much larger deflections in the case of an empty tower and moderately larger deflections in the case of an added mass model than the use of matched accelerograms. This is attributed to the assumption that artificial accelerograms carry higher frequency content than the matched accelerograms. In the case of liquid-filled tower, the source of an accelerogram had a negligible effect on the response which demonstrates that the liquid fill increases the fundamental period compared to the added mass model. The liquid fill was noted to affect the structural response not only by its mass but also by its motion. Analyses conducted with the empty tower and the added mass model resulted in underestimation of deflections by 37.1 % and overestimation of deflections by 35.1 %, respectively. In conclusion, this study demonstrates that the fluid-structure interaction significantly affects the dynamic behavior of a structure during a seismic event. |
Abstract (fin): | Tässä diplomityössä esitellään numeerinen menetelmä nesteellä täytetyn reaktoritornin maanjäristystarkastelulle standardin EN 1998 mukaisia aikahistorioita käyttäen. Standardin EN 1998 ohjeet ja vaatimukset seismisen kuorman esittämiseksi aikahistoriana selostetaan ja niiden mukaiset aikahistoriat tuotetaan kahdella eri menetelmällä. Ensimmäiset aikahistoriat valitaan kansainvälisestä tietokannasta ja manipuloidaan siten, että niiden taajuussisältö vastaa haluttua vastespektriä. Toiset aikahistoriat sen sijaan tuotetaan keinotekoisesti tarkoitukseen sopivalla ohjelmalla. Numeerisessa menetelmässä rakenteet mallinnetaan perinteisellä Lagrangen menetelmällä ja neste ALE-menetelmällä (arbitrary Lagrangian-Eulerian). ALE-menetelmän perusyhtälöt ja niiden ratkaisuun soveltuva menettely, nestettä kuvaava Mie-Grüneisen tilayhtälö sekä nesteen ja rakenteen vuorovaikutuksen aikaansaava kytkentäalgoritmi esitellään työssä. Kytkentäalgoritmi havainnollistetaan jousi-vaimenninsysteeminä ja siihen liittyvällä ongelmalla. Numeerinen menetelmä verifioidaan kolmella, aikaisempiin tutkimusjulkaisuihin perustuvilla esimerkeillä ja osoitetaan menetelmän luotettavuus. Teollisen mittakaavan nesteellä täytetty reaktoritorni analysoidaan sekä taajuudeltaan manipuloiduilla että keinotekoisilla kolmiaksiaalisilla maanjäristyksen aikahistorioilla. Sekä nesteellä täytetyn että tyhjän tornin vaakasiirtymät manipuloitujen ja keinotekoisten aikahistorioiden johdosta määritetään. Tyhjän tornin tapauksessa neste otetaan huomioon myös pelkkänä massana. Tämän diplomityön tuloksena saadaan tietoa sekä aikahistorian valintaprosessin että nesteen vaikutuksesta tornin rakenteelliseen toimintaan. Pystysuora maaperän liike ei vaikuttanut rakenteen vasteeseen, koska vertikaalisena ulokkeena tornilla ei ole merkittäviä ominaismuotoja pystysuoraan suuntaan. Keinotekoisten aikahistorioiden käyttö johti paljon suurempiin siirtymiin tyhjän tornin tapauksessa ja hieman suurempiin siirtymiin nesteen massan huomioon ottavan tornin tapauksessa. Tämän katsotaan aiheutuvan keinotekoisten aikahistorioiden korkeammasta taajuussisällöstä. Nesteellä täytetyn tornin tapauksessa aikahistorian alkuperällä ei ole merkittävää vaikutusta siirtymiin, mikä osoittaa nesteen kasvattavan rakenteen ominaisperiodia nesteen pelkkänä massana huomioon ottavaan torniin verrattuna. Tornin täyttäminen nesteellä vaikutti rakenteen siirtymiin massan lisäksi myös nesteen liikkeen kautta. Tornin analysointi tyhjänä johti maksimisiirtymän aliarvioimiseen 37.1 %:lla ja vastaavasti nesteen huomiointi pelkkänä massana johti maksimisiirtymän yliarvioimiseen 35.1 %:lla. Johtopäätöksenä rakenteen ja nesteen välinen vuorovaikutus vaikuttaa merkittävästi rakenteen toimintaan maanjäristyksen aikana. |
ED: | 2014-04-06 |
INSSI record number: 48873
+ add basket
« previous | next »
INSSI