Author:Kettunen, Outi
Title:Pystyeristysseinä pilaantuneiden maiden eristysrakenteena
Vertical cut-off walls at contaminated sites
Publication type:Master's thesis
Publication year:2005
Pages:120+14      Language:   fin
Department/School:Rakennus- ja ympäristötekniikan osasto
Main subject:Pohjarakennus ja maamekaniikka   (Rak-50)
Supervisor:Ravaska, Olli
Instructor:Forsman, Juha
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto     | Archive
Keywords:vertical cut-off wall
cement-bentonite slurry
quality control
pystyeristysseinä
sementtibentoniittiliete
laadunvalvonta
Abstract (eng): This thesis explores the use of vertical cut-off walls as a barrier at contaminated sites.
It comprises a literature survey, examples for calculating the stability of slurry trenches, laboratory tests and a case study.

The literature survey presents the most common cut-off methods, which include soil-bentonite and cement-bentonite slurry walls, the vibrating beam method, stabilisation, deep soil mixing, jet grouting, steel and HDPE sheet piling, ground freezing and permeable reactive barrier walls.

Two different methods for calculating the stability of cement-bentonite slurry trenches are presented complete with sample calculations.
Laboratory tests for slurry are also presented, as the proportions of the cement-bentonite slurry are determined by testing slurry properties before construction.
The end of the literature survey concentrates on quality control during construction, working methods for trench excavation and the cost of cement-bentonite cut-off walls.

In 2004-2005, a cement-bentonite slurry wall was constructed to contain an old waste disposal site in Myllypuro, Helsinki.
The depth of the wall ranges from 2 to 12 m and the wall is anchored to a low-permeability soil layer or bedrock.
The Myllypuro case study includes a detailed description of the permission procedure, the process of selecting the contractor and independent quality controller, working methods, quality control and the schedule at the construction site.
Abstract (fin): Tässä diplomityössä käsitellään pystyeristysseiniä pilaantuneiden maiden eristämisessä.
Työ koostuu kirjallisuusselvityksestä, mitoitusesimerkeistä, laboratoriokokeista ja Myllypuron kohteen esittelystä.

Kirjallisuusselvityksessä esitellään lyhyesti yleisimpiä pystyeristysmenetelmiä: maabentoniitti-, sementtibentoniittiliete- ja tärypalkkimenetelmät, pilaristabilointi, deep soil mixing, suihkuinjektointi, teräs- ja muoviponttiseinät, maan jäädytys sekä reaktiivinen seinä.

Sementtibentoniittilieteseinien osalta esitellään kaksi käytännön kokemuksiin perustuvaa lietteen täyttämän kaivannon stabiliteetin mitoitusmenetelmää.
Sementtibentoniittilieteseinien osalta käsitellään myös seinän suunnitteluvaiheessa lietteelle tehtäviä ennakkokokeita, joiden perusteella valitaan kuhunkin kohteeseen koostumukseltaan sopiva liete.
Kirjallisuusselvityksen lopuksi esitellään sementtibentoniittilieteseinien rakennusaikaisia laadunvalvontatoimenpiteitä, kaivannon tekemisen työtekniikoita sekä lieteseinien kustannuksiin vaikuttavia tekijöitä.

Helsingin Myllypuroon rakennetaan vanhan kaatopaikka-alueen ympärille noin 850 m pitkä sementtibentoniittilieteseinä v. 2004 - 2005, jonka keskelle asennetaan lukkoponteilla varustettu HDPE-kalvo.
Seinän korkeus 2 - 12 metriä ja se ulotetaan syvyyssuunnassa tiiviiseen maakerrokseen tai kallioon saakka.
Myllypuron kohteesta on tässä työssä kerrottu ympäristölupaprosessi tutkimuksista luvan myöntämiseen saakka, urakoitsijan ja riippumattoman laadunvalvojan valinta, työmaan laadunvalvontaorganisaatio sekä kuvattu työmaan työmenetelmiä, laadunvalvontaa sekä aikataulua.