search query: @keyword LabVIEW / total: 32
reference: 2 / 32
« previous | next »
Author:Mustonen, Ville
Title:Development of a health chair for non-invasive patient monitoring
Terveystuolin kehitys potilaan kajoamattomaan mittaukseen
Publication type:Master's thesis
Publication year:2013
Pages:x + 69 s. + liitt. 23      Language:   eng
Department/School:Sähkötekniikan korkeakoulu
Main subject:Bioniikka   (S3006)
Supervisor:Sepponen, Raimo
Instructor:Linnavuo, Matti
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201401101097
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  1098   | Archive
Keywords:patient monitoring
electrocardiogram
oxygen saturation
photoplethysmogram
pulse arrival time
pulse transit time
RR interval
QT interval
terveystuoli
monitorointi
elektrokardiogrammi
pulssioksimetri
happisaturaatio
LabVIEW
plethysmogrammi
pulssiaikaviive
RR-intervalli
QT-intervalli
Abstract (eng):Aalto University's Health Factory executed development process to realize a health chair for monitoring patient state of health.
Aim of this master's thesis was to participate into the technical development of the health chair.
This included designing wanted measurements to pilot designs from selected OEM modules.
Including all the necessary coupling and programming to implement modules to monitoring state.
The thesis introduces LabVIEW programs and couplings done to these modules on each pilot design.
Aim was also to design, execute and test estimating of patient's systolic blood pressure with pulse transit time method.
A design of dry-electrode contact electrocardiography measurement from chosen ECG module was supposed to be realized.
Automated calculations of RR and QT intervals were done.
The thesis also collects information related to realize pilot design measurements.
The thesis introduces health chair's first pilot design, which worked as test platform to test the chosen measurement modules and verify their compatibility to use.
Necessary programs and couplings were made to monitor the measurements.
Secondly the master's thesis introduces second health chair pilot design.
The design was more developed.
It included blood pressure, weight, photoplethysmography, electrical bioimpedance, blood oxygen saturation and heart rate measurements.
All these measurement were executed on this health chair.
The third pilot design was not finished during this master's thesis.
The third pilot design was designed to include electrocardiography, weight, bioelectrical impedance, blood oxygen saturation, heart rate and photoplethysmography measurement and estimation of systolic blood pressure from pulse transit time.
The thesis introduces designed dry-electrode ECG measurement.
It introduces two systolic blood pressure estimation methods and RR and QT interval calculations.
The calculations and systolic blood pressure estimation methods were made with LabVIEW.
The designs of these programs are presented.
Every measurement was completed on each module.
Tests were made to five persons from different age categories.
Firstly, functioning of second pilot design measurements were tested.
Aim of the test was to verify that measurements could be executed with second pilot design.
Results are presented in the thesis and refer that all the tests were completed.
Secondly, usability of RR and QT interval calculations were tested.
Aim of the test was to compare the results made with automated LabVIEW measurements and manually calculated result with Matlab.
RR interval calculations had smaller standard deviation and median error than QT interval calculations.
RR calculations were considered precise.
Lastly, systolic blood pressure was estimated with measured pulse transit times from these five test persons.
Two different estimation methods were used.
Considering the results the method is neither compatible to determine absolute blood pressure or detecting small changes of systolic blood pressure but could be compatible for monitoring systolic blood pressure in long periods.
Abstract (fin):Tämän diplomityön tarkoituksena oli osallistua Aalto-yliopiston Health Factoryn kehittämän terveystuolin tekniseen kehitykseen.
Terveystuolia kehitettiin potilaan terveydentilan seurantaan.
Terveystuolin kehitys tapahtui toteuttamalla tarvittavat mittausmoduulit monitorointiasteelle.
Diplomityössä esitellään pilottituoleihin valituille moduulille tehdyt LabVIEW-ohjelmat ja tarvittavat kytkennät.
Nämä mahdollistivat mittausmoduuleilla monitoroinnin.
Tarkoituksena oli myös suunnitella, toteuttaa ja testata pulssiaikaviiveellä toteutettu potilaan systolisen verenpaineen arviointi.
Potilaan EKG oli tarkoitus mitata kuivaelektrodeilla, joiden toteutus esitellään.
Tarkoituksena oli myös toteuttaa automatisoitu RR- ja QT-intervallien mittaus valitulle EKG-moduulille.
Myös tiedon keruu pilottien kehitysvaiheista oli osatavoitteena diplomityössä.
Diplomityö esittelee terveystuolin ensimmäisen pilotin, joka toimi koealustana valituille moduuleilla.
Sen tarkoituksena oli kokeilla moduulien toimivuus käyttötarkoitukseen.
Käyttöönottoon tehdyt tarvittavat LabVIEW-ohjelmat ja kytkennät tehtiin ja ne esitellään.
Terveystuolin toinen pilotti toimi koekäyttötuolina ja muistutti enemmän lopullista terveystuolia.
Se sisälsi verenpaine-, paino-, plethysmografia-, kudosimpedanssi-, happisaturaatio- ja sykemittaukset.
Näihin toteutetut ohjelmat ja kytkennät esitellään.
Kolmas pilotti ei valmistunut tämän diplomityön aikana.
Sen kehitys oli tarkoituskin jatkua.
Tuolin oli tarkoitus sisältää EKG-, paino-, kudosimpedanssi-, happisaturaatio-, syke- ja plethymografiamittaukset sekä systolisen verenpaineen arvioinnin pulssiaikaviiveen avulla.
Diplomityö esittelee siihen kuivaelektrodi kytkennän, joka suunniteltiin EKG-mittaukseen.
Tehdyt RR-ja QT-intervallien automaattiset mittausmenetelmät esitellään.
Suunnitellut menetelmät systolisen verenpaineen arviointiin pulssiaikaviiveellä esitellään.
Diplomityössä toteutettiin mittaukset onnistuneesti jokaiseen siinä käytettyyn mittausmoduuliin.
Työssä suoritettiin kokeita viidelle henkilölle.
Ensinnäkin terveystuolin toisen pilotin mittaukset suoritettiin.
Tulokset esitellään ja todettiin että kaikki mittaukset on toteutettavissa.
Toiseksi RR- ja QT-intervallien automaattinen laskenta testattiin.
LabVIEW-ohjelman laskemia tuloksia verrattiin MatLabilla manuaalisesti mitattuihin tuloksiin.
RR-intervalleilla oli pienempi standardi deviaatio ja pienempi mediaani virhe kuin QT-intervalleilla.
Ne saavuttivat tyydyttävän tarkkuuden.
Viimeiseksi systolisen verenpaineen arviointi pulssiaikaviiveellä kokeiltiin kahdella eri tavalla.
Tuloksissa todetaan että pulssiaikaviive ei ole sopiva absoluuttisen verenpaineen arviointiin, eikä sen tarkkuus riitä huomioimaan pieniä verenpaineen muutoksia, mutta se voisi olla sopiva menetelmä pitkä aikaiseen verenpaineen seurantaan.
ED:2014-01-19
INSSI record number: 48430
+ add basket
« previous | next »