search query: @keyword rakentamismääräyskokoelma / total: 4
reference: 4 / 4
« previous | next »
Author:Tähtinen, Lauri
Title:Toimistorakennuksen julkisivun energiakorjaus
Energy-efficient facade renovation of an office building
Publication type:Master's thesis
Publication year:2010
Pages:110      Language:   fin
Department/School:Insinööritieteiden ja arkkitehtuurin tiedekunta
Main subject:Talonrakennustekniikka   (Rak-43)
Supervisor:Sistonen, Esko
Instructor:Matilainen, Pellervo
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto     | Archive
Keywords:energy renovation
energy efficiency
facade renovation
extra thermal insulation
energiakorjaus
energiatehokkuus
julkisivukorjaus
peittävä korjaus
vaihtava korjaus
lisälämmöneristys
rakentamismääräyskokoelma
Abstract (eng): The first goal of this thesis is to determine the commonly used fa9ade structures of office buildings built between the years of 1970-1989.
The second goal is to determine how much energy savings could be obtained by fa9ade renovation of those buildings.
The study is limited to buildings with reinforced concrete hull and facades made out of sandwich elements or by masonry.
The aim of this study is to find the renovation-concepts to reduce energy consumption m office buildings, and to fulfil different building regulations.

Thermal transmittance of office buildings wall structures were improved twice during the studied period.
In 1975, the average insulation thickness increased from 90 mm to 120 mm and in 1985 to 140 mm.
Coefficient thermal transmittances were 0.41, 0.35 and 0.29 W/m2K.

Energy savings from external insulation and reconstruction of the insulation of buildings of different ages were calculated with a variety of insulation materials and thicknesses, using thermal transmittances from old regulations as input data.
Based on these findings the optimal thicknesses and materials for buildings of different ages and facade structures were determined.

The amount and type of additional insulation needed to upgrade buildings of different ages to low-energy or passive level, or to fulfil new building regulations, were also calculated.

Based on the calculations, it was concluded that the current level of external insulation used in many renovations is very close to the optimal thickness of mineral wool and therefore it should not be changed.
However, if a certain level of energy consumption is to be achieved, better insulation materials are soon needed.
The insulation capacity of mineral wool is only efficient for the implementation of the year 2010 regulations.
The amount of thermal insulation needed to achieve the low-energy level no longer favours the use of mineral wool.
Therefore polyurethane should be used instead.
To create passive houses, new and greatly more efficient insulation materials are needed to maintain sensible insulation thicknesses.
Abstract (fin): Tässä työssä selvitetään vuosina 1970 - 1989 rakennettujen toimistorakennusten julkisivurakenteita ja niiden korjaamisesta saatavia energiansäästöjä.
Tutkimus rajataan teräsbetonirunkoisiin sandwich-elementeistä tehtyihin ja muurattuihin julkisivuihin.
Työn tavoitteena on löytää toimivat konseptit rakennusten energiankulutuksen pienentämiseen, sekä erilaisten määräys- ja energiankulutustasojen mukaisten rakenteiden toteuttamiseen.

Toimistorakennusten seinärakenteiden lämmönläpäisykerrointa oli parannettu kahdesti tutkitulla aikavälillä.
Vuonna 1975 keskimääräinen eristepaksuus kasvoi 90 millimetristä 120 millimetriin ja vuonna 1985 140 millimetriin.
Vastaavat lämmönläpäisykertoimet olivat 0.41, 0.35 ja 0.29 W/m2K.

Käyttämällä lähtötietoina määräysten mukaisia lämmönläpäisykertoimia, laskettiin eri-ikäisille rakennuksille sekä peittävästä että vaihtavasta korjauksesta saatavat energiansäästöt eristepaksuuden funktiona, erilaisia eristemateriaaleja käyttäen.
Näiden tulosten perusteella määritettiin kuinka paljon ja millä materiaaleilla eri-ikäisiä rakennuksia kannattaa eristää.

Lisäksi laskettiin kuinka paljon ja minkälaista lisäeristystä eri-ikäiset rakennukset tarvitsevat, jotta niistä voidaan tehdä matalaenergia- tai passiivitaloja tai uudet rakentamismääräykset täyttäviä rakennuksia.

Tehdyistä laskelmista pääteltiin, että nykyinen lisälämmöneristystaso on hyvin lähellä mineraalivillan optimipaksuutta, eikä lisäeristystä kannata paksuntaa.
Mikäli korjauksella kuitenkin halutaan saavuttaa jokin tietty taso, riittää mineraalivillan eristyskyky vielä vuoden 2010 rakentamismääräysten mukaisten rakennusten toteuttamiseen.
Lisälämmöneristäminen matalaenergiatasoon ei mineraalivillaa käyttäen enää kannata, mutta se voidaan toteuttaa polyuretaanilla.
Passiivitalojen toteuttamiseen järkevillä eristepaksuuksilla tarvitaan nykyistä huomattavasti tehokkaampia eristeitä.