Author: | Kuuluvainen, Leino |
Title: | Design stage analysis of a wastewater heat recovery system by simulation of a low energy building |
Jäteveden lämmöntalteenottojärjestelmän suunnitteluvaiheen analyysi matalaenergiatalon simuloinnilla | |
Publication type: | Master's thesis |
Publication year: | 2013 |
Pages: | 86 + [13] Language: eng |
Department/School: | Energiatekniikan laitos |
Main subject: | Ydin- ja energiatekniikka (Tfy-56) |
Supervisor: | Lund, Peter |
Instructor: | Alanne, Kari |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark Aalto 270 | Archive |
Keywords: | wastewater heat recovery ground source heat pumps heat pumps residential buildings single family houses jäteveden lämmöntalteenotto maalämpöpumput lämpöpumput asuintalot pientalot |
Abstract (eng): | In the future, wastewater heat recovery will need to be used in residential buildings as one method of increasing energy efficiency. In this study a method of wastewater heat recovery suitable for single family houses was tested to investigate how much it can reduce electricity consumption. In the tested system energy from wastewater is recovered by using the ground source heat pump that is the main heating source of the building. In addition, an economic analysis was done to find the circumstances under which wastewater heat recovery in single family houses can be economically profitable in general. The wastewater heat recovery system was tested using a case study. The analysis of the heat recovery system was done as a part of the design process of a large single family house. The case study included simulation tests of the building and its heating system. The simulation tests were done with the TRNSYS 17.0 program. According to the results of the simulation test, the wastewater heat recovery system did not increase heat pump performance significantly, thus, electricity saving was low. However, the heat recovery efficiency of the system was high. Installing the tested system was not deemed economically profitable. The best way to improve the performance of the system would be installing a separate heat pump for wastewater heat recovery. The results of the economic calculations revealed that with current electricity prices wastewater heat recovery in a single family house with a separate heat pump would likely not be economically profitable. On the other hand, with electricity price of 20 c/kWh wastewater heat recovery can become economically profitable in systems where the main heating source is direct electric heating, for example, in passive houses. |
Abstract (fin): | Tulevaisuudessa jäteveden lämmöntalteenotto tulee olemaan yksi tärkeä keino asuintalojen energiatehokkuuden parantamisessa. Tässä tutkimuksessa testattiin yhtä omakotitaloihin soveltuvaa jäteveden lämmöntalteenottotekniikkaa ja sen potentiaalia vähentää sähkön kulutusta. Tutkimuksen kohteena olevan järjestelmän toiminta perustuu jäteveden lämmöntalteenottoon käyttäen maalämpöpumppua, joka on rakennuksen päälämmönlähde. Lisäksi suoritettiin taloudelliset laskelmat. joiden tavoitteena oli löytää ehdot. joiden pitää täyttyä, jotta jäteveden lämmöntalteenotto pientaloissa olisi taloudellisesti kannattavaa. Lämmöntalteenottojärjestelmää tutkittiin tapaustutkimuksella. Tapaustutkimus sisälsi suuren omakotitalon ja sen lämmitysjärjestelmän simulointikokeet. Lämmöntalteenottojärjestelmän analyysi suoritettiin osana rakennuksen suunnitteluprosessia. Simulointikokeet suoritettiin TRNSYS 17.0 -ohjelmistolla. Simulointitestien tulosten perusteella jäteveden lämmöntalteenoton käyttö ei parantanut lämpöpumpun suorituskykyä merkittävästi, ja siksi sähkönkulutuksessa ei saavutettu suurta säästöä. Järjestelmän lämmöntalteenoton hyötysuhde oli kuitenkin korkea. Järjestelmän asennuksen ei katsottu olevan taloudellisesti perusteltua. Paras tapa järjestelmän suorituskyvyn parantamiseen olisi erillisen lämpöpumpun asentaminen jäteveden lämmöntalteenottoa varten. Taloudelliset laskelmat osoittivat, että jäteveden lämmöntalteenotto erillisellä lämpöpumpulla ja nykyisillä sähkön hinnoilla ei todennäköisesti olisi kannattavaa pientaloissa. Toisaalta sähkön hinnalla 20 c/kWh jäteveden lämmöntalteenotto voi olla taloudellisesti kannattavaa järjestelmissä, joissa päälämmönlähde on sähkölämmitys. Tämä tarkoittaa esimerkiksi passiivitaloia. |
ED: | 2013-10-21 |
INSSI record number: 47367