Author:Torkkeli, Kalle
Title:Paine-eroon perustuva pinnanmittausmentelmä Loviisan ydinvoimalaitoksen simulointimalliin
Implementation of the differential pressure level measurement method into the simulation model of the Loviisa nuclear power plant
Publication type:Master's thesis
Publication year:2010
Pages:[7] + 64 s. + liitt. 9      Language:   fin
Department/School:Automaatio- ja systeemitekniikan laitos
Main subject:Systeemitekniikka   (AS-74)
Supervisor:Koivo, Heikki
Instructor:Kontio, Harri
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  5443   | Archive
Keywords:differential pressure measurement
level measurement
VVER-440
simulation
APROS
paine-eromittaus
pinnanmittaus
VVER-440
simulointi
APROS
Abstract (eng): In this Master's Thesis, the water level measurement systems of the pressurizer and the steam generator were implemented into the Apros model of the Loviisa nuclear power plant.
In the power plant, the water level is measured using the differential pressure method.
The pressure difference is measured between the ends of two impulse pipe lines connected to the upper and the lower part of the process component.
The pressure difference is transformed into the water level signal based on the hydrostatic pressure equation.
Earlier in the simulation model, the water level calculation was less realistically based on collapsed liquid level, which is the sum of the liquid levels of the stacked thermal hydraulic nodes of the component.
The modelling of the level measurement system for the pressurizer did not cause any problems.
In the modelling of the steam generator measurements, difficulties were caused by too simplified thermal hydraulic calculation level structure of the Apros component.
However, after tuning the parameters of the calculation level modules, the level measurements behaved more realistically.

The simulated level measurements were compared to the actual data from the plant transients.
The measurements of the pressurizer performed similarly as the original collapsed liquid level, whereas behaviour of the measurements of the steam generator resembled the plant data clearly more than the original measurements.
Abstract (fin): Diplomityössä mallinnettiin paineistimen ja höyrystimen pinnanmittausjärjestelmät Loviisan ydinvoimalaitoksen APROS-malliin.
Laitoksella paineistimen ja höyrystimen veden pinta mitataan paine-eromenetelmällä.
Komponentin ylä- ja alaosaan kytkeytyy impulssiputkilinjat, joiden loppupäiden välinen paine-ero muutetaan pinnankorkeudeksi perustuen hydrostaattisen paineen laskukaavaan.
Aikaisemmin simulointimallissa pinnankorkeus oli laskettu epärealistisemmin kollapsipinnasta, joka on komponentin päällekkäisten termohydraulisten noodien pinnankorkeuksien summa.

Uusien pinnanmittausjärjestelmien mallintaminen paineistimelle onnistui ongelmitta.
Höyrystimellä vaikeuksia aiheutti Apros-komponentin liian yksinkertainen laskentatason rakenne.
Höyrystimen laskentatason moduulien parametreja muuttamalla mittaukset saatiin kuitenkin käyttäytymään realistisesti.

Simuloituja pinnanmittauksia verrattiin mittauksiin oikeista laitostransienteista.
Paineistimella mittaukset käyttäytyivät niissä samalla tavalla kuin alkuperäinen kollapsipinta.
Höyrystimen uudet mittaukset käyttäytyivät transienteissa alkuperäisiä paremmin laitosmittauksien kaltaisesti.