Author:Renvall, Ville
Title:Physical simulation of blood oxygen level variation in functional magnetic resonance imaging
Veren hapetustason muutosten fysikaalinen simulointi toiminnallisessa magneettikuvauksessa
Publication type:Master's thesis
Publication year:2004
Pages:xiv + 60 s. + liitt. 10      Language:   eng
Department/School:Teknillisen fysiikan ja matematiikan osasto
Main subject:Lääketieteellinen tekniikka   (Tfy-99)
Supervisor:Katila, Toivo
Instructor:Joensuu, Raimo
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark TF80     | Archive
Keywords:fMRI
MRI
NMR
quality assurance
simulation
laadunvarmennus
simulointi
Abstract (eng): Functional magnetic resonance imaging is a popular method in brain research.
It can pinpoint secondary metabolic activity following electrical Signalling of neurons.
Typically, the extent of an identified activation is several voxels while some of them are activated more than others.

The purpose of the current study was to develop a method and device, which would signify whether an activation of certain intensity in a specified voxel of certain size determines the metabolism of the tissue represented by the voxel or does it represent the residual spread intensity of another voxel.
In practise, this could clarify the scientific terminology where activations currently described as large could be characterised more precisely in terms of intensity and spread.

The work consisted of designing and constructing a phantom system and the accompanying signalling system.
The systems were tested and a methodology for the spatial location assurance was developed.
The work was done in the Advanced Magnetic Imaging Centre of Helsinki University of Technology.
Abstract (fin): Toiminnallinen magneettikuvaus on paljon käytetty menetelmä aivotutkimuksessa.
Sillä voidaan paikallistaa esimerkiksi hermosolujen sähköisen viestimisen seurauksena tapahtuvaa aineenvaihduntaa.
Havaitun ilmiön tilavuus on tavallisesti laajuudeltaan useita tilavuuskuvan alkioita ja ilmiön voimakkuus vaihtelee tilavuusalkiosta toiseen.

Tämän tutkimuksen tarkoitus oli kehittää menetelmä ja laitteisto, joilla voidaan selvittää, josko on mahdollista, että. tietyssä tilavuuskuvan alkiossa havaittu aktivaatiointensiteetti voi syntyä vain sitä vastaavassa näytetilavuudessa.
Vaihtoehtona on ilmiön intensiteetin leviäminen ympäröiviin kuva-alkioihin siten, että signaalilähde, jonka tulkiltaan olevan laaja, voikin olla pienikokoinen ja voimakas.
Käytännössä menetelmällä voidaan selventäviä suuriksi luonnehdittujen aktivaatioiden luokittelua laajoihin ja voimakkaisiin.

Työ käsitti mittausfantomin ja sen ohjausjärjestelmän suunnittelun ja toteutuksen.
Laitteet testattiin ja kehitettiin menetelmä toiminnallisen magneettikuvauksen paikkatarkkuuden varmistamiseen.
Työ tehtiin Teknillisen korkeakoulun AMI-keskuksessa.