search query: @instructor Hyvönen, Petri / total: 6
reference: 3 / 6
Author: | Lehto, Anne-Mari |
Title: | Kahdenkymmenen kV:n salamasyöksyjännitegeneraattorin kehittäminen |
Devising a 20 kV Lightning Impulse Generator | |
Publication type: | Master's thesis |
Publication year: | 2008 |
Pages: | ix, 74 Language: fin |
Department/School: | Elektroniikan, tietoliikenteen ja automaation tiedekunta |
Degree programme: | Elektroniikan ja sähkötekniikan tutkinto-ohjelma |
Main subject: | Sähköverkot ja suurjännitetekniikka (S-18) |
Supervisor: | Lehtonen, Matti |
Instructor: | Hyvönen, Petri |
Electronic version URL: | http://urn.fi/urn:nbn:fi:tkk-012024 |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark S80 | Archive |
Keywords: | impulse voltage generator lightning impulse (LI) high voltage testing insulation co-ordination syöksyjännitegeneraattori testaustekniikka salamasyöksyjännite eristyskoordinaatio |
Abstract (eng): | High voltage testing is used to explore and confirm electric strength of devices. The test voltages are always higher than the operating voltages. The tests needed are specified in different standards. Selecting of the proper electric strength is influenced both by the safety issues and cost factors. Of help to this selecting there has been developed an insulation co-ordination. Lightning impulse voltage (LI) is used as one of the test voltages in high voltage testing. LI is generated by a lightning impulse generator, which basicly consists of a high voltage DC source, resistors and capacitors. With LI generators at High Voltage Laboratory of HUT (Helsinki University of Technology) it's possible to produce lightning impulse voltages under 4 kV or over 20 kV. However, testing within the voltage range between those is difficult with these equipments. Therefore it became necessary to build up a generator to produce voltages from 1 kV to 20 kV. This Thesis covers the devising of this 20 kV lightning impulse generator built at HUT. |
Abstract (fin): | Suurjännitetesteillä tutkitaan ja todennetaan laitteiden jännitelujuusominaisuuksia. Käytettävät koejännitteet ovat aina laitteen suurinta käyttöjännitettä suurempia ja tarvittavat testit on määritelty eri standardeissa. Sopivan jännitelujuuden valintaan vaikuttaa mm. laitteen turvallisuus sekä kustannustekijät. Valinnan avuksi on kehitetty eristyskoordinaatio. Salamasyöksyjännite on impulssimainen salamaa simuloiva jännite, jota käytetään yhtenä koejännitteistä suurjännitetesteissä. Salamasyöksyjännite saadaan aikaiseksi syöksyjännitegeneraattorilla, jonka peruspiiri muodostuu tasajännitelähteestä, vastuksista sekä kondensaattoreista. TKK:n (Teknillinen Korkeakoulu) suurjännitelaboratoriossa olevilla syöksyjännitegeneraattoreilla pystytään tuottamaan yli 20 kV:n sekä alle 4 kV:n syöksyjännitteitä. Väliin jäävällä jännitealueella testaus on kuitenkin näillä laitteilla hankalaa, minkä vuoksi haluttiin rakentaa kyseisellä jännitealueella toimiva salamasyöksyjännitegeneraattori. Tämä diplomityö käsittelee TKK:lle rakennetun 20 kV:n salamasyöksyjännitegeneraattorin suunnittelua ja rakentamista. |
ED: | 2008-09-16 |
INSSI record number: 36241
+ add basket
INSSI