Author:Nieminen, Tommi Juhani
Title:Simulointi korkeiden liikerakennusten poistumisturvallisuuden kehittämisessä
Simulation in the improvement of egress safety in tall buildings
Publication type:Master's thesis
Publication year:2011
Pages:114      Language:   fin
Department/School:Rakennustekniikan laitos
Main subject:Talonrakennustekniikka   (Rak-43)
Supervisor:Puttonen, Jari
Instructor:Laaksonen, Juha-Pekka
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto     | Archive
Keywords:egress
evacuation
tall building
evacuation simulation
FDS+Evac
poistuminen
evakuointi
korkea rakennus
poistumissimulointi
FDS+Evac
Abstract (eng): Tall buildings being rare in Finland, the present Finnish egress regulations have been made for buildings of moderate height only, not taking into account the special characteristics of tall buildings.
The objective of this thesis was to use evacuation simulation to establish the deciding factors in the egress from tall buildings and to evaluate their role in egress safety.
In addition, the objective was to measure the level of egress safety ensued from the present Finnish regulations and to discover further means to reach an equivalent or even higher safety level in tall buildings.
Also, the suitability of simulation as a method in egress research was thus piloted in the thesis.

The Finnish egress regulations and design methods constituted the groundwork for the research.
In addition, social psychology literature was consulted to study human behaviour in evacuation situations and the egress systems of existing tall buildings were examined.
Next, a suitable evacuation simulation program (FDS+Evac) was chosen and validated for the research by first simulating real life evacuation drills.
Finally, the program was used to examine the role of staircase geometry in evacuation and the functionality of various egress systems in a 40-storey model building.

The study proved stimulation a useful tool for comparing different egress systems.
First, the stimulations revealed that a typical Finnish staircase, now 1200 mm wide, could be improved by widening it to 1300 - 1400 mm.
This could be done within the limits of the stair floor area by reducing the landings that the study showed to be oversized and removing the embrasures that were found to be redundant.
Second, the stimulation of a 40-storey model building proved that an egress system designed following the Finnish regulations would in fact function rather well in buildings up to this height.
However, the system was found to waste floor area, and it was discovered that concentrating the overall egress capacity to the lower part of the building would allow speeding up the evacuation.
Finally, it was noted that the egress safety could be further improved by using the elevators for evacuation and by evacuating the building in stages.
Abstract (fin): Korkeista rakennuksista ja niistä poistumisesta on Suomessa vasta vähän kokemuksia, eikä niihin liittyviä erityispiirteitä siten ole juuri huomioitu Suomen nykyisissä poistumismääräyksissä.
Tutkimuksen tavoitteena oli selvittää poistumissimuloinnin avulla tärkeimmät korkeista rakennuksista poistumiseen vaikuttavat tekijät ja arvioida niiden merkitystä poistumisturvallisuudelle.
Lisäksi tavoitteena oli arvioida, miten hyvä poistumisturvallisuustaso Suomen nykyisillä poistumismääräyksillä saavutetaan, ja millä muilla ratkaisuilla voitaisiin päästä samaan tai parempaan lopputulokseen.
Samalla testattiin myös simuloinnin käyttökelpoisuutta poistumistutkimuksessa.

Tutkimuksen pohjaksi selvitettiin Suomessa käytettävät poistumismääräykset ja -mitoitusmenetelmät, tutustuttiin ihmisten käyttäytymistä poistumistilanteessa käsittelevään sosiaalipsykologian kirjallisuuteen sekä perehdyttiin olemassa olevien korkeiden rakennusten poistumisjärjestelyihin.
Varsinaista tutkimusta varten valittiin sopiva poistumissimulointiohjelma (FDS+Evac), jonka toimintaa validoitiin todellisia poistumisharjoituksia simuloimalla.
Simulointiohjelmalla tutkittiin ensin tiettyjen poistumisgeometrian yksityiskohtien vaikutusta poistumiseen, minkä jälkeen testattiin erilaisten poistumisratkaisujen toimivuutta 40-kerroksisen esimerkkirakennuksen avulla.

Tutkimuksessa todettiin simuloinnin olevan käyttökelpoinen työkalu erilaisten poistumisratkaisujen vertailussa.
Simulointien perusteella havaittiin, että Suomessa yleisen 1200 mm leveän uloskäytävän toimintaa voitaisiin parantaa luopumalla ylileveistä välitasanteista sekä ovisyvennyksistä ja käyttämällä näin vapautuva tila portaan leventämiseen 1300 - 1400 mm:iin.
Lisäksi todettiin, että 40-kerroksisessa esimerkkirakennuksessa suomalaisten taulukkopalomääräysten mukaiset uloskäytävät olivat riittävät, mutta ne eivät käyttäneet varaamaansa tilaa kovin tehokkaasti.
Poistuminen sujuisikin nopeammin, mikäli porraskapasiteettia kohdennettaisiin rakennuksen alaosaan.
Poistumisturvallisuutta voitaisiin parantaa myös ottamalla rakennuksen hissit evakuointikäyttöön ja suorittamalla evakuointi vaiheittain.