search query: @instructor Turunen, Markus / total: 65
reference: 39 / 65
« previous | next »
Author:Veijanen, Terhi
Title:Mukautumiskykyiset keinomykiöt ja ikänäön korjaaminen
Accommodating intraocular lenses and presbyopia correction
Publication type:Master's thesis
Publication year:2010
Pages:[9] + 111      Language:   fin
Department/School:Elektroniikan, tietoliikenteen ja automaation tiedekunta
Main subject:Elektroniikan valmistustekniikka   (S-113)
Supervisor:Paulasto-Kröckel, Mervi
Instructor:Turunen, Markus
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201203131460
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  1552   | Archive
Keywords:accommodating intraocular lens
accommodative intraocular lens
presbyopia
presbyopia-correcting IOLs
IOL
mukautumiskykyinen keinomykiö
akkommodatiivinen intraoku-laarilinssi
ikänäkö
ikänäön korjaaminen
Abstract (eng): The ultimate goal in the field of cataract and refractive surgery is to find a patient-satisfying solution to restore the accommodation of the eye.
This solution would en-able the correction of presbyopia and the restoration of accommodation after cataract surgery.
Several approaches have been proposed to restore accommodation but so far the problem has not been solved well enough.
One of the trends in the field is the development of an accommodating intraocular lens.
If such a lens was functioning properly, the ultimate goal would be achieved.
The solution would possibly have high impact on national health, too.
This thesis deals with these accommodating intraocular lenses and their state of development.
Their potential to develop into presbyopia-correcting intraocular lenses is also discussed.

Furthermore, other problems in the field are discussed, since they have a remarkable effect on the development of accommodating intraocular lenses, too.
These other problems include, for example, the formation of posterior capsule opacification and problems with the inaccuracies and methodologies of the eye measuring devices.
Accommodating intraocular lenses on the market at present have proven to be mostly non-functional, when the accommodative response was measured objectively.
Anyhow, when subjective measuring methods were used, the average near visual acuity of the patients was better com-pared to that measured from the patients with regular intraocular lenses.
In the future the focus of the use of intraocular lenses seems to move toward the use of accommodating intraocular lenses as technologies grow better and above mentioned problems will be solved.
Abstract (fin): Hyvän toiminnallisen näkökyvyn palauttaminen ikänäöstä kärsiville ja kaihileikkauksen läpikäyneille potilaille on edelleen saavuttamatta.
Tämän ongelman korjaamiseksi on esitetty useita erilaisia ratkaisumalleja.
Yksi kaihi- ja taittovirhekirurgian alan keskeisimmistä kehityssuuntauksista nykypäivänä on mukautumiskykyisten keinomykiöiden kehittäminen.
Jos tällainen keinomykiö saataisiin kehitettyä kaikin puolin toimivaksi, ratkaisisi se alan suurimman ongelman toiminnallisen näkökyvyn palauttajana ja sillä olisi myös suuri merkitys kansanterveydellisesti.

Tässä kirjallisuustyönä laaditussa diplomityössä käsitellään näitä mukautumiskykyisiä keinomykiöitä.
Työssä esitellään eri kehitysvaiheissa olevia kirjallisuudessa esiintyviä keinomykiömalleja sekä näiden potentiaalia kehittyä ikänäön korjaaviksi teknologioiksi.
Lisäksi käsitellään kilpailevia ratkaisuja ikänäön korjaamiseksi sekä muita alalla esiintyviä vielä ratkaistavia ongelmia, jotka vaikuttavat myös mukautumiskykyisten keinomykiöiden kehitykseen.
Näitä ongelmia ovat muun muassa jälkikaihen muodostuminen sekä silmän ominaisuuksien mittausmenetelmissä olevat puutteet ja epätarkkuudet.

Nykyiset markkinoilla olevat mukautumiskykyiset keinomykiöt ovat osoittautuneet pää-sääntöisesti toimimattomiksi objektiivisissa mittauksissa.
Subjektiivisten mittaustulosten mukaan ne pystyvät kuitenkin tuottamaan potilaalle paremman lähinäön kyvyn kuin tavalliset keinomykiöt.
Tulevaisuudessa keinomykiöiden painopiste siirtynee mukautumiskykyisten keinomykiöiden suuntaan sitä mukaa, kun teknologiat paranevat ja ongelmakohtia saadaan ratkaistua.
ED:2010-08-16
INSSI record number: 40102
+ add basket
« previous | next »
INSSI