Author:Markkanen, Kimmo
Title:Väestöhälyttimien ohjausjärjestelmän ja palokuntien hälytysjärjestelmän toiminnan varmistaminen
Selecting Technologies for the Control System of Public Warning Sirens and Fire Brigade Alarms
Publication type:Master's thesis
Publication year:2007
Pages:viii + 63 s. + liitt. 14      Language:   fin
Department/School:Sähkö- ja tietoliikennetekniikan osasto
Main subject:Tietoverkkotekniikka   (S-38)
Supervisor:Kantola, Raimo
Instructor:Kankkunen, Kenneth
Electronic version URL: http://urn.fi/urn:nbn:fi:tkk-010030
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark S80     | Archive
Keywords:alarm
rescue services
hälyttäminen
pelastustoimi
POCSAG
TETRA
VIRVE
Abstract (eng):The field of Rescue Services in Finland has gone through three major changes.
TETRA based public security and safety radio network VIRVE, multi-agency Emergency Response Centres and regional rescue services have been built.
These changes, together with technological possibilities, have created the need to harmonize and adopt new solutions for controlling the system of public warning sirens and for mobilizing the rescue personnel.

In this thesis we study different solutions for mobilizing the rescue personnel and for controlling the public warning sirens.
We also look for solutions to control the state of the equipments.

The solution for the control system of the public warning sirens was selected by evaluating the functional requirements related to costs.
The air interface of VIRVE suits the purpose well.
For the sirens we decided to build reservation for wired controls by IP- and traditional telephone network.

For evaluating the usability of rescue personnel alarming system, we conducted interviews and used questionnaires.
The evaluating was made by using analytical hierarchy process.
For the alternatives besides the TETRA-terminal, we studied suitability of cellular phones, analogue pagers and DARC-pagers.

The ordinary cellular phone showed to be the most cost-effective solution.
To make the system more robust, a decision was made to build a separate paging network.
Pagers conforming to the POCSAG-standard were chosen.
The POCSAG base stations are controlled using VIRVE and wired IP-network.

Both systems are controlled by four independent control computers, which are located at the control room of rescue department and three command centres.
The control computers are connected to VIRVE through the air interface and wired to IP-network.
Abstract (fin):Suomen pelastustoimen kenttä on käynyt läpi kolme merkittävää muutosprosessia.
On otettu käyttöön TETRA-standardiin perustuva viranomaisradioverkko VIRVE, moniviranomaishätäkeskukset sekä alueellinen pelastustoimi.
Nämä muutokset, yhdessä tekniikan antamien mahdollisuuksien kanssa, ovat luoneet tarpeen yhdenmukaistaa ja toteuttaa uusia ratkaisuja väestöhälyttimien ohjaukseen sekä pelastushenkilöstön hälyttämiseen.

Työssä selvitimme tarjolla olevia ratkaisuvaihtoehtoja pelastushenkilöstön hälyttämiseen ja väestöhälyttimien ohjaukseen.
Ohjausjärjestelmällä haimme ratkaisua myös järjestelmän kuuluvien laitteiden kunnon valvontaan.

Väestöhälyttimien ohjauksessa ratkaisun teimme arvioimalla toiminnallisia vaatimuksia suhteessa kustannuksiin.
Tarkoituksenmukaiseksi osoittautui ohjausten rakentaminen suoraan ilmateitse VIRVE:llä.
Hälyttimille rakensimme myös varauksen langallisia ohjauksia varten sekä IP- että perinteisessä puhelinverkossa.

Pelastushenkilöstön hälyttämisratkaisun käytettävyyden arvioimiseksi teimme haastatteluja ja kyselyitä.
Näiden tuloksia arvioimme käyttämällä analyyttistä hierarkiaprosessia.
Vaihtoehtoina tutkimme viranomaisradioverkon päätelaitteen lisäksi matkapuhelimen, analogisen hakulaitteen ja DARC-hakulaitteen soveltuvuutta.

Kustannustehokkaimmaksi ratkaisuksi osoittautui yleisen verkon matkapuhelin.
Toimintavarmuuden parantamiseksi päädyimme täydentämään tätä rakentamalla Länsi-Uudellemaalle erillisen hakulaiteverkon.
Hakulaitteeksi valittiin POCSAG-standardin mukaiset hakulaitteet.
POCSAG-tukiasemia hallitaan sekä VIRVE:llä että langallisessa IP-verkossa.

Molempia järjestelmiä hallitaan neljällä toisistaan riippumattomalla hallintatietokoneella, jotka on sijoitettu pelastuslaitoksen valvomoon ja kolmeen johtokeskukseen.
Hallintatietokoneet on liitetty ilmarajapinnalla VIRVE-verkkoon ja langalliseen IP-verkkoon.
ED:2007-12-10