search query: @keyword virtausmittaus / total: 7
reference: 6 / 7
« previous | next »
Author:Renvall, Tommi
Title:Virtausmittaus kokonaisnäytemenetelmällä
Flow measurement with total sample method
Publication type:Master's thesis
Publication year:2004
Pages:iv + 75 s. + liitt. 12      Language:   fin
Department/School:Teknillisen fysiikan ja matematiikan osasto
Main subject:Ydin- ja energiatekniikka   (Tfy-56)
Supervisor:Salomaa, Rainer
Instructor:Antson, Olli
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark TF80     | Archive
Keywords:flow measurement
total sample method
tracer
merkkiaine
virtausmittaus
kokonaisnäytemenetelmä
Abstract (eng): The aim of the present work was to study total sample method in flow meter calibration.
Total sample method is a tracer technique that is based on dilution of the tracer pulse.
In the present work we aimed at applying the total sample method to calibrate flow meters in nuclear power plant's (NPP) turbine circuits.
The built measurement equipment was to be prototype for calibration equipment.
With the used equipment, total uncertainty of the measurements was to be less than 1% (2 sigma confidence).

Because of the accuracy limit and the process conditions, radioactive 23Na (Na2CO3) was used as a tracer.
Process pressure and photon energy were high, and thus a variation of total sample method, in which tracer concentration during tracer feed varies, was used.

The first version of the measurement equipment was tested in the Finnish flow meter calibrating site where real process conditions were not possible.
These tests were made with 99mTc tracer.
During the tests, the measurement equipment was mainly unstable.
However, one of the tests was successful with less than 1 % deviation from the true flow.

Altogether three field tests were made, two at TVO I (BWR) primary circuit and one at Loviisa II (PWR) secondary circuit.
At TVO I the process conditions were too challenging and neither of the tests were successful.
The improved equipment worked well in Loviisa II, but the tracer (99mTc) adsorbed to the process pipes surface, and no accuracy measurements were obtained.

Based on the total sample method, it is possible to build flow measurement equipment that is well suited for calibrating flow meters.
The equipment has the potential to reach 0,2% accuracy (2 sigma) in good process conditions.
Further development is still needed to obtain reliable field measurement equipment.
Abstract (fin): Työssä tutkittiin kokonaisnäytemenetelmän soveltuvuutta virtausmittareiden kalibrointiin.
Kokonaisnäytemenetelmä on harvoin käytetty menetelmä, joka perustuu merkkiaineen laimenemiseen virtauksessa.
Tässä työssä oli tarkoituksena soveltaa menetelmää erityisesti ydinvoimalaitosten turbiinipiirin virtausmittareiden kalibrointiin.
Tutkimusta varten rakennettiin virtausmittauslaitteisto, jonka piti toimia myös akkredoidun mittauslaitteiston prototyyppinä.
Tarkkuustavoitteeksi laitteistolle asetettiin alle 1 %:n kokonaisepävarmuus (2 sigman luottamusvälillä).

Tarkkuustavoitteen ja ydinvoimalaolosuhteiden vuoksi merkkiaineena päädyttiin käyttämään radioaktiivista 23Na:a (kemiallinen muoto Na2CO3).
Koska mitattavan virtauksen paine ja käytetyn isotoopin gammaenergia olivat korkeita, merkkiaineensyötössä käytettiin muuttuvaa merkkiainekonsentraatiota.

Laitteiston ensimmäisen version tarkkuutta testattiin virtausmittareiden kalibrointiasemalla, jossa virtaus oli paljon voimalaitosmittausta pienempi ja prosessiolosuhteet helpommat Kalibrointiasemalla tehdyissä vertailumittauksissa merkkiaineena käytettiin 99mTc:ia.
Laitteiston häiriöiden takia vain yksi koe onnistui.
Kyseisessä kokeessa alitettiin asetettu 1 %:n tarkkuusvaatimus.

Kenttäkokeita tehtiin kolme, kaksi TVOI -primääripiirissä ja yksi Loviisa II -sekundääripiirissä.
Prosessiolosuhteet kenttäkokeissa olivat liian haastavat merkkiaineensyöttö- ja näytteenkeruulaitteistolle eikä TVO:lla pystytty viemään läpi yhtään koetta kokonaisuudessaan.
Kehitetty laitteistoversio toimi Loviisan kokeessa, mutta käytetty merkkiaine 99mTc tarttui prosessiputken seinämiin ja vertailumittauksen tulos jäi saamatta.

Kokonaisnäytemenetelmällä voidaan toteuttaa kalibrointimittauksiin sopiva virtausmittauslaitteisto, jolla voidaan hyvissä prosessiolosuhteissa saavuttaa 0,2 %:n (2 sigman) tarkkuus.
Akkredoidun kenttäkelpoisen laitteiston rakentaminen vaatii kuitenkin vielä kehitystyötä.
ED:2004-07-14
INSSI record number: 25437