search query: @keyword linearity / total: 7
reference: 1 / 7
« previous | next »
Author: | Dönsberg, Timo |
Title: | Improved Reference Infrared Spectrometer |
Uudistettu referenssi-infrapunaspektrometri | |
Publication type: | Master's thesis |
Publication year: | 2012 |
Pages: | ix + 77 s. + liitt. 13 Language: eng |
Department/School: | Signaalinkäsittelyn ja akustiikan laitos |
Main subject: | Mittaustekniikka (S-108) |
Supervisor: | Ikonen, Erkki |
Instructor: | Manoocheri, Farshid |
Electronic version URL: | http://urn.fi/URN:NBN:fi:aalto-201209213135 |
OEVS: | Electronic archive copy is available via Aalto Thesis Database.
Instructions Reading digital theses in the closed network of the Aalto University Harald Herlin Learning CentreIn the closed network of Learning Centre you can read digital and digitized theses not available in the open network. The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/ You can read theses on the Learning Centre customer computers, which are available on all floors.
Logging on to the customer computers
Opening a thesis
Reading the thesis
Printing the thesis
|
Location: | P1 Ark Aalto 710 | Archive |
Keywords: | infrared spectrometer automation linearity photoconductive detector infrapuna spektrometri automaatio lineaarisuus valojohtava ilmaisin |
Abstract (eng): | Infrared radiation is electromagnetic radiation with a spectrum ranging from 750 nm to 1 mm in wavelength. It is invisible to the human eye, but has significance in optical spectroscopy. An optical spectrometer is a device that measures the emission, absorption, or fluorescence spectrum of a material. In this work, a reference infrared spectrometer facility at the Metrology Research Institute was upgraded. The spectrometer can be used to measure spectral responsivity of detectors, spectral transmittance of optical materials and spectral power distribution measurements of light sources in the wavelength range of 750 nm to 16 ?m. The measurement setup was improved for full automation using LabVIEW and the previous calibration and automation procedures were refined. Automated facility is versatile for different measurement setups and is easy to operate. Phase sensitive detection is utilized in the measurement setup by using a lock-in amplifier. It enables the detection of very small signals in the presence of overwhelming noise. Optical chopping is used to modulate the measurement signal at a known reference frequency. Typically the linearity of the measurement system is determined optically. Also in this work, a fully electronic method for linearity measurements of lock-in amplifiers was developed and tested. This method improves the accuracy in lock-in comparison measurements. In addition, a preamplifier for photoconductive detectors was constructed and characterized. The amplifier was designed so that it can be used with wide variety of detectors. |
Abstract (fin): | Infrapunasäteily on sähkömagneettista säteilyä, jonka aallonpituus on 750 nn - 1 mm. Se on tärkeä työväline optisessa spektroskopiassa, vaikka onkin ihmissilmälle näkymätöntä. Optisella spektrometrillä tarkoitetaan laitetta, joka mittaa materiaalin emissio-, absorptio- tai fluoresenssispektriä. Tässä työssä uudistettiin Aalto-yliopiston Mittaustekniikan ryhmän referenssi-infrapunaspektrometriä. Laitetta käytetään ilmaisimen vasteen, aineen läpäisyn ja lähteen tehojakauman spektrisiin mittauksiin aallonpituusalueella 750 nm - 16 µm. Mittauslaitteisto automatisoitiin käyttäen LabVIEW-ohjelmistoa. Lisäksi kalibrointi- ja mittausmenetelmiä paranneltiin. Automatisoitu mittauslaitteisto soveltuu monipuolisesti erilaisiin mittausjärjestelyihin ja on aiempaa helpompi käyttää. Mittauksissa käytetään vaihelukittua vahvistinta, joka mahdollistaa hyvin heikkojen signaalien havaitsemisen suuren kohinasignaalin läsnäolosta huolimatta. Mitattavaa signaalia moduloidaan katkomalla valolähdettä referenssitaajuudella. Optisen menetelmän sijaan vaihelukitun vahvistimen lineaarisuusmittauksiin kehitettiin täysin sähköinen menetelmä, joka parantaa ulkoista tarkkuutta vertailumittauksissa. Lisäksi osana työtä suunniteltiin, rakennettiin ja karakterisoitiin esivahvistin valojohtaville ilmaisimille. Tavanomaisesta sovitetusta esivahvistimesta poiketen laitteen keskeiset parametrit ovat säädettäviä, joten sitä voidaan käyttää lukuisien eri ilmaisimien kanssa. |
ED: | 2012-04-25 |
INSSI record number: 44281