Author:Zevenhoven, Koos Cornelis Jacobus
Title:Solving transient problems in ultra-low-field MRI
Transienttiongelmien ratkaiseminen ultramatalan kentän MRI:ssä
Publication type:Master's thesis
Publication year:2011
Pages:61      Language:   eng
Department/School:Teknillisen fysiikan laitos
Main subject:Lääketieteellinen tekniikka   (Tfy-99)
Supervisor:Ilmoniemi, Risto
Instructor:Clarke, John
Electronic version URL: http://urn.fi/URN:NBN:fi:aalto-201305163099
OEVS:
Electronic archive copy is available via Aalto Thesis Database.
Instructions

Reading digital theses in the closed network of the Aalto University Harald Herlin Learning Centre

In the closed network of Learning Centre you can read digital and digitized theses not available in the open network.

The Learning Centre contact details and opening hours: https://learningcentre.aalto.fi/en/harald-herlin-learning-centre/

You can read theses on the Learning Centre customer computers, which are available on all floors.

Logging on to the customer computers

  • Aalto University staff members log on to the customer computer using the Aalto username and password.
  • Other customers log on using a shared username and password.

Opening a thesis

  • On the desktop of the customer computers, you will find an icon titled:

    Aalto Thesis Database

  • Click on the icon to search for and open the thesis you are looking for from Aaltodoc database. You can find the thesis file by clicking the link on the OEV or OEVS field.

Reading the thesis

  • You can either print the thesis or read it on the customer computer screen.
  • You cannot save the thesis file on a flash drive or email it.
  • You cannot copy text or images from the file.
  • You cannot edit the file.

Printing the thesis

  • You can print the thesis for your personal study or research use.
  • Aalto University students and staff members may print black-and-white prints on the PrintingPoint devices when using the computer with personal Aalto username and password. Color printing is possible using the printer u90203-psc3, which is located near the customer service. Color printing is subject to a charge to Aalto University students and staff members.
  • Other customers can use the printer u90203-psc3. All printing is subject to a charge to non-University members.
Location:P1 Ark Aalto  243   | Archive
Keywords:ultra-low-field
ULF
MRI
magnetic resonance
eddy current
transient
mutual inductance
magnetically shielded room
magnetic screening
shielding coil
dynamic shielding
transient cancellation
ultramatala kenttä
ULF
magneettikuvaus
MRI
pyörrevirta
transientti
keskinäisinduktanssi
magneettisuojahuone
esipolarisointi
suojakela
dynaaminen suojaus
transienttien kumoaminen
SQUID
Abstract (eng): Magnetic resonance imaging (MRI) is widely used in clinical applications as well as in research.
While the state of the art of MRI has developed towards using multiple-tesla magnetic fields, another approach has emerged, where the signal is measured in a magnetic field on the order of Earth's magnetic field (~ 100 µT).
Such ultra-low-field (ULF) MRI is made possible by highly-sensitive magnetic-field sensor technology based on superconducting quantum interference devices (SQUIDs).
For increasing the signal-to-noise ratio (SNR), the sample is pre-polarized in a larger field (~ 100 mT) before each acquisition cycle.
ULF MRI has interesting characteristics including unique contrast mechanisms, safety, silent operation, and potential in low cost and in compatibility with other electromagnetically sensitive technology.

MRI acquisition is based on measuring the nuclear magnetic resonance (NMR) resulting in the sample from applying various magnetic field pulses.
Pulsing magnetic fields, especially the pre-polarizing field, however, causes a number of problems, mainly related to unwanted electromagnetic induction to other parts of the measurement apparatus and its surroundings.
Eddy currents induced in the walls of the magnetically shielded room (MSR), which is required for low-noise measurements, are a particularly serious issue.
The eddy currents generate a transient magnetic field, disturbing data acquisition and affecting the NMR.

In this Thesis, I discuss the problems of pulse-induced transient effects and what they have in common.
I adapt theory of linear systems to the effects and present methods and approaches for solving them.
In particular, I derive a quantitative theory of eddy currents and magnetic shielding by them in the walls of an MSR.
Some of these methods and approaches were applied to the ULF-MRI system at University of California, Berkeley.
A number of upgrades were made to the system to solve several serious transient issues that made imaging impossible with a new coil setup meant to significantly improve the image quality.
Among these upgrades, a new MSR was designed and constructed to reduce transient eddy currents.
Time-dependent measurements of the eddy-current patterns in the MSR walls show excellent agreement with calculations based on the presented theory.
Imaging tests show that the upgrades were successful.

For transient suppression, I also present a method in which additional time-varying pulses are applied in the system to spatiotemporally couple to the transient effects, providing highly flexible means of simultaneously canceling transients at different time scales.
A simulation study is presented, suggesting that this method can provide much better results than any pre-existing method.
ED:2011-09-22
INSSI record number: 42798